Bubble induced shear stress in flat sheet membrane systems-Serial examination of single bubble experiments with the electrodiffusion method

被引:21
作者
Boehm, Lutz [1 ]
Drews, Anja [2 ]
Kraume, Matthias [1 ]
机构
[1] Tech Univ Berlin, Chair Chem Proc Engn, D-10587 Berlin, Germany
[2] HTW Berlin Univ Appl Sci, Sch Life Sci Engn, D-12459 Berlin, Germany
关键词
Flat sheet membrane module; Bubble; Shear stress; Electrodiffusion method; MASS-TRANSFER; SLUG FLOW; FLUID DISTRIBUTION; 2-PHASE FLOW; ULTRAFILTRATION; MODULE; SURFACE; THICKNESS; SINK;
D O I
10.1016/j.memsci.2013.02.036
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
With regard to the improvement of the cleaning process of flat sheet membrane modules by aeration, a statistical analysis of the shear stress generated by single bubbles is shown for 21 different parameter combinations of varied channel depths, bubble sizes and liquid velocities. A fully automated rig allowed the generation of a sufficient database of shear stress data gained with the electrodiffusion method (EDM). The maximum shear stresses and the global shear stress levels, where the latter represents the global shear stress fluctuations, were determined. To the authors' knowledge, for the first time in membrane research a transient correction of the EDM data was performed which is necessary in cases of highly transient processes. By showing different probability ranges gained from cumulative distribution functions in bar plots, a way of presenting the data was introduced that simplifies the comparison between the different geometrical and operating parameter combinations. Additionally, this type of diagram offers a very comprehensive overview of the measured data. Both the maximum shear stress and the global shear stress levels are larger when the bubble is larger than the channel depth and when an additional liquid velocity is superimposed. In all cases, the transient correction yielded higher values. Thus it is necessary to take this measure. In the investigated range, the highest maximum values were obtained for the case with super-imposed liquid velocity, a channel depth of 5 mm and a bubble size of 9 mm with appr. 1.3 Pa (steady analysis) or 4.7 Pa (transient corrected analysis), respectively. The largest fluctuation ranges of the global shear stress levels were obtained for a channel depth of 5 mm and a bubble size of 9 mm with values from appr. 0.2 to 1.1 Pa (steady analysis) or 0 to 2.6 Pa (transient corrected analysis). (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:131 / 140
页数:10
相关论文
共 24 条
[1]   Quantifying the shear at the surface of submerged hollow fiber membranes [J].
Bérubé, PR ;
Afonso, G ;
Taghipour, F ;
Chan, CCV .
JOURNAL OF MEMBRANE SCIENCE, 2006, 279 (1-2) :495-505
[2]   The importance of fluid dynamics for MBR fouling mitigation [J].
Boehm, Lutz ;
Drews, Anja ;
Prieske, Helmut ;
Berube, Pierre R. ;
Kraume, Matthias .
BIORESOURCE TECHNOLOGY, 2012, 122 :50-61
[3]   Shear profiles inside gas sparged submerged hollow fiber membrane modules [J].
Chan, C. C. V. ;
Berube, P. R. ;
Hall, E. R. .
JOURNAL OF MEMBRANE SCIENCE, 2007, 297 (1-2) :104-120
[4]  
Ducom G, 2003, CAN J CHEM ENG, V81, P771
[5]   Air sparging with flat sheet nanofiltration: a link between wall shear stresses and flux enhancement [J].
Ducom, G ;
Puech, FP ;
Cabassud, C .
DESALINATION, 2002, 145 (1-3) :97-102
[6]   Distribution of surface shear forces and bubble characteristics in full-scale gas sparged submerged hollow fiber membrane modules [J].
Fulton, B. G. ;
Redwood, J. ;
Tourais, M. ;
Berube, P. R. .
DESALINATION, 2011, 281 :128-141
[7]   Optimizing the sparging condition and membrane module spacing for a ZW500 submerged hollow fiber membrane system [J].
Fulton, Blair G. ;
Berube, Pierre R. .
DESALINATION AND WATER TREATMENT, 2012, 42 (1-3) :8-16
[8]   Influence of fluid distribution on the ultrafiltration performance of a ceramic flat sheet membrane [J].
Gaucher, C ;
Jaouen, P ;
Legentilhomme, P ;
Comiti, J .
SEPARATION SCIENCE AND TECHNOLOGY, 2003, 38 (09) :1949-1962
[9]   Influence of fluid distribution on the wall shear stress in a plane ultrafiltration module using an electrochemical method [J].
Gaucher, C ;
Legentilhomme, P ;
Jaouen, P ;
Comiti, J .
CHEMICAL ENGINEERING RESEARCH & DESIGN, 2002, 80 (A1) :111-120
[10]  
Gaucher C, 2002, EXP FLUIDS, V32, P283, DOI [10.1007/s003480100317, 10.1007/S003480100317]