Conducting polymer microactuators operating in air

被引:80
作者
Alici, Gursel [1 ]
Devaud, Valerie [2 ]
Renaud, Philippe [2 ]
Spinks, Geoff [1 ]
机构
[1] Univ Wollongong, Sch Mech Mat & Mechatron Engn, Wollongong, NSW 2522, Australia
[2] Swiss Fed Inst Technol Lausanne EPFL, Ctr MicroNano Technol, Lausanne, Switzerland
关键词
ACTUATORS; SPEED;
D O I
10.1088/0960-1317/19/2/025017
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We report for the first time on microsized conducting polymer actuators, which operate in air and in liquids. These actuators are potentially useful for a wide range of applications from biotechnology to microrobots. Furthermore, the actuators are fabricated using an excimer laser ablation technique, which does not require clean-room facilities and can provide high throughput production. Preliminary characterization results presented show that the tip displacement of the microactuators is linearly proportional to the magnitude of the input voltage.
引用
收藏
页数:9
相关论文
共 24 条
[1]   A methodology towards geometry optimization of high performance polypyrrole (PPy) actuators [J].
Alici, G ;
Metz, P ;
Spinks, GM .
SMART MATERIALS AND STRUCTURES, 2006, 15 (02) :243-252
[2]   Establishment of a biomimetic device based on tri-layer polymer actuators-propulsion fins [J].
Alici, Gursel ;
Spinks, Geoffrey ;
Huynh, Nam N. ;
Sarmadi, Laleh ;
Minato, Rick .
BIOINSPIRATION & BIOMIMETICS, 2007, 2 (02) :S18-S30
[3]   Performance quantification of conducting polymer actuators for real applications: A microgripping system [J].
Alici, Gursel ;
Huynh, Nam N. .
IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2007, 12 (01) :73-84
[4]  
Ataka M., 1993, Journal of Microelectromechanical Systems, V2, P146, DOI 10.1109/84.273089
[5]  
Benecke W., 1989, Proceedings: IEEE Micro Electro Mechanical Systems. An Investigation of Micro Structures, Sensors, Actuators, Machines and Robots (IEEE Cat. No.89THO249-3), P116, DOI 10.1109/MEMSYS.1989.77974
[6]   Excimer laser polymer ablation: twenty years on [J].
Dyer, PE .
APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2003, 77 (02) :167-173
[7]  
Ebefors T., 1999, in 1999 10th Int. Conf. on SolidState Sensors, P1202
[8]   Robust adaptive control of conjugated polymer actuators [J].
Fang, Yang ;
Tan, Xiaobo ;
Alici, Guersel .
IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2008, 16 (04) :600-612
[9]  
Frisch-Fay R., 1962, Flexible bars
[10]   The cell clinic:: Closable microvials for single cell studies [J].
Jager, EWH ;
Immerstrand, C ;
Peterson, KH ;
Magnusson, KE ;
Lundström, I ;
Inganäs, O .
BIOMEDICAL MICRODEVICES, 2002, 4 (03) :177-187