SARS-CoV-2 RNA detection in the air and on surfaces in the COVID-19 ward of a hospital in Milan, Italy

被引:201
作者
Razzini, Katia [1 ]
Castrica, Marta [2 ]
Menchetti, Laura [3 ]
Maggi, Lorenzo [4 ]
Negroni, Lucia [1 ]
Orfeo, Nicola, V [1 ]
Pizzoccheri, Alice [1 ]
Stocco, Matteo [1 ]
Muttini, Stefano [1 ]
Balzaretti, Claudia M. [2 ]
机构
[1] St PM & Carlo Hosp, Via Antonio Rudini 8, I-20142 Milan, Italy
[2] Univ Milan, Dept Hlth Anim Sci & Food Safety Carlo Cantoni, Via Celoria 10, I-20133 Milan, Italy
[3] Univ Perugia, Dept Vet Med, Via San Costanzo 4, I-06126 Perugia, Italy
[4] Chemserv Srl Lab Anal Grp, Via F Lli Beltrami 15, I-20026 Milan, Italy
关键词
COVID-19; Coronavirus; Outbreak; Airborne transmission; Environmental contamination; Infection control; ACUTE RESPIRATORY SYNDROME; SARS; CORONAVIRUSES; TRANSMISSION; OUTBREAK;
D O I
10.1016/j.scitotenv.2020.140540
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The COVID-19 outbreak has rapidly progressed worldwide finding the health system, scientists and society unprepared to face a little-known, fast spreading, and extremely deadly virus. Italy is one of the countries hardest hit by the pandemic, resulting in healthcare facilities bearing heavy burdens and severe restrictive measures. Despite efforts to clarify the virus transmission, especially in indoor scenarios, several aspects of SARS-CoV-2 spread are still rudimentary. This study evaluated the contamination of the air and surfaces by SARS-CoV-2 RNA in the COVID-19 isolation ward of a hospital in Milan, Italy. A total of 42 air and surface samples were collected inside five different zones of the ward including contaminated (COVID-19 patients' area), semi-contaminated (undressing room), and dean areas. SARS-CoV-2 RNA detection was performed using real time reverse transcription polymerase chain reaction. Overall, 24.3% of swab samples were positive, but none of these were collected in the clean area Thus, the positivity rate was higher in contaminated (35.0%) and semi-contaminated (50.0%) areas than in clean areas (0.0%; P<0.05). The most contaminated surfaces were hand sanitizes dispensers (100.0%), medical equipment (50.0%), medical equipment touch screens (50.0%), shelves for medical equipment (40.0%), bedrails (333%), and door handles (25.0%). All the air samples collected from the contaminated area, namely the intensive care unit and corridor, were positive while viral RNA was not detected in either semi-contaminated or dean areas. These results showed that environmental contamination did not involve dean areas, but the results also support the need for strict disinfection, hand hygiene and protective measures for healthcare workers as well as the need for airborne isolation precautions. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:7
相关论文
共 41 条
[1]  
[Anonymous], 2020, COVID-19
[2]  
[Anonymous], 2009, Natural Ventilation for Infection Control in Healthcare Settings
[3]   Detection of airborne severe acute respiratory syndrome (SARS) coronavirus and environmental contamination in SARS outbreak units [J].
Booth, TF ;
Kournikakis, B ;
Bastien, N ;
Ho, J ;
Kobasa, D ;
Stadnyk, L ;
Li, Y ;
Spence, M ;
Paton, S ;
Henry, B ;
Mederski, B ;
White, D ;
Low, DE ;
McGeer, A ;
Simor, A ;
Vearncombe, M ;
Downey, J ;
Jamieson, FB ;
Tang, P ;
Plummer, F .
JOURNAL OF INFECTIOUS DISEASES, 2005, 191 (09) :1472-1477
[4]   Turbulent Gas Clouds and Respiratory Pathogen Emissions Potential Implications for Reducing Transmission of COVID-19 [J].
Bourouiba, Lydia .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2020, 323 (18) :1837-1838
[5]  
CDS, 2020, GUID CLEAN DIS PUBL
[6]   A familial cluster of pneumonia associated with the 2019 novel coronavirus indicating person-to-person transmission: a study of a family cluster [J].
Chan, Jasper Fuk-Woo ;
Yuan, Shuofeng ;
Kok, Kin-Hang ;
To, Kelvin Kai-Wang ;
Chu, Hin ;
Yang, Jin ;
Xing, Fanfan ;
Liu, Jieling ;
Yip, Cyril Chik-Yan ;
Poon, Rosana Wing-Shan ;
Tsoi, Hoi-Wah ;
Lo, Simon Kam-Fai ;
Chan, Kwok-Hung ;
Poon, Vincent Kwok-Man ;
Chan, Wan-Mui ;
Ip, Jonathan Daniel ;
Cai, Jian-Piao ;
Cheng, Vincent Chi-Chung ;
Chen, Honglin ;
Hui, Christopher Kim-Ming ;
Yuen, Kwok-Yung .
LANCET, 2020, 395 (10223) :514-523
[7]   Escalating infection control response to the rapidly evolving epidemiology of the coronavirus disease 2019 (COVID-19) due to SARS-CoV-2 in Hong Kong [J].
Cheng, Vincent C. C. ;
Wong, Shuk-Ching ;
Chen, Jonathan H. K. ;
Yip, Cyril C. Y. ;
Chuang, Vivien W. M. ;
Tsang, Owen T. Y. ;
Sridhar, Siddharth ;
Chan, Jasper F. W. ;
Ho, Pak-Leung ;
Yuen, Kwok-Yung .
INFECTION CONTROL & HOSPITAL EPIDEMIOLOGY, 2020, 41 (05) :493-498
[8]   Air and environmental sampling for SARS-CoV-2 around hospitalized patients with coronavirus disease 2019 (COVID-19) [J].
Cheng, Vincent Chi-Chung ;
Wong, Shuk-Ching ;
Chan, Veronica Wing-Man ;
So, Simon Yung-Chun ;
Chen, Jonathan Hon-Kwan ;
Yip, Cyril Chik-Yan ;
Chan, Kwok-Hung ;
Chu, Hin ;
Chung, Tom Wai-Hin ;
Sridhar, Siddharth ;
To, Kelvin Kai-Wang ;
Chan, Jasper Fuk-Woo ;
Hung, Ivan Fan-Ngai ;
Ho, Pak-Leung ;
Yuen, Kwok-Yung .
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2020, 41 (11) :1258-1265
[9]  
Chin AWH, 2020, LANCET MICROBE, V1, pE10, DOI [10.1016/S2666-5247(20)30003-3, 10.1016/S2666-5247(20)30095-1]
[10]   Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR (Publication with Expression of Concern) [J].
Corman, Victor M. ;
Landt, Olfert ;
Kaiser, Marco ;
Molenkamp, Richard ;
Meijer, Adam ;
Chu, Daniel K. W. ;
Bleicker, Tobias ;
Bruenink, Sebastian ;
Schneider, Julia ;
Schmidt, Marie Luisa ;
Mulders, Daphne G. J. C. ;
Haagmans, Bart L. ;
van der Veer, Bas ;
van den Brink, Sharon ;
Wijsman, Lisa ;
Goderski, Gabriel ;
Romette, Jean-Louis ;
Ellis, Joanna ;
Zambon, Maria ;
Peiris, Malik ;
Goossens, Herman ;
Reusken, Chantal ;
Koopmans, Marion P. G. ;
Drosten, Christian .
EUROSURVEILLANCE, 2020, 25 (03) :23-30