Effect of Twin Delta-Winged Twisted-Tape on Thermal Performance of Heat Exchanger Tube

被引:30
|
作者
Eiamsa-Ard, Smith [1 ]
Nuntadusit, Chayut [2 ]
Promvonge, Pongjet [3 ]
机构
[1] Mahanakorn Univ Technol, Dept Mech Engn, Bangkok 10530, Thailand
[2] Prince Songkla Univ, Dept Mech Engn, Hat Yai, Thailand
[3] King Mongkuts Inst Technol Ladkrabang, Fac Engn, Bangkok, Thailand
关键词
FRICTION FACTOR CHARACTERISTICS; TRANSFER ENHANCEMENT; PRESSURE-DROP; LAMINAR-FLOW; SYSTEM;
D O I
10.1080/01457632.2013.793112
中图分类号
O414.1 [热力学];
学科分类号
摘要
This work aims at studying the effect of twin delta-winged twisted-tape insertion on heat transfer, pressure drop, and thermal performance characteristics of a heat exchanger tube. All twisted tapes used in this work were made of aluminum sheets twisted at a single twist ratio of 3.0. The twin delta wings were formed by extrusion of the tape at the center area at every twist length interval. For comparison, three different arrangements of the twin delta wings were: (1) the wing tips pointing upstream of the flow (TTW-up, twin delta-winged twisted tape in counterflow arrangement), (2) the wing tips pointing downstream of the flow (TTW-down, twin delta-winged twisted tape in co-flow arrangement), and (3) the wing tips pointing opposite direction (TTW-o, opposite winged twisted tape). The wing declination was arranged at an angle of 15 degrees with respect to the tape surface. Effects of three different wing-tip angles of 20 degrees, 40 degrees, and 60 degrees for a constant wing base were examined. The experiments were conducted using water as the test fluid in a uniform-heat-flux tube for Reynolds number between 5000 and 15,000. The results demonstrate that the TTW-up consistently provides greater heat transfer rate, friction factor, and thermal performance factor than the TTW-down and the TTW-o, at a similar condition. In addition, the heat transfer rate increases as the wing-tip angle decreases. Over the range investigated, the TTW-up with wing-tip angle of 20 degrees gives the highest thermal performance factor of 1.26 along with a Nusselt number and friction factor of 2.57 and 8.55times those of the plain tube.
引用
收藏
页码:1278 / 1288
页数:11
相关论文
共 50 条
  • [41] HYDRODYNAMIC AND THERMAL PERFORMANCE OF TWISTED TAPE INSERT PROVIDED IN HEAT EXCHANGER TUBES: A REVIEW
    Datt, Ravi
    Kumar, Anil
    Bhist, Mangal Singh
    Kothiyal, Alok Darshan
    Maithani, Rajesh
    FRONTIERS IN HEAT AND MASS TRANSFER, 2019, 12
  • [42] Evaluation of thermal performance factor by hybrid nanofluid and twisted tape inserts in heat exchanger
    Fouad, Noor
    Hamza, A.
    Aljabair, Sattar
    HELIYON, 2022, 8 (12)
  • [43] Numerical evaluation of the effect of using various twisted-tape geometries on heat transfer enhancement and flow characteristics in a tube
    Sara Taheripour
    Mohammad Reza Saffarian
    Noushin Azimy
    Mehrsa Aghajari
    Journal of Thermal Analysis and Calorimetry, 2023, 148 : 7829 - 7844
  • [44] PERFORMANCE ENHANCEMENT BY PERFORATED TWISTED TAPE TUBE INSERT WITH SINGLE AND DOUBLE V CUTS IN A HEAT EXCHANGER TUBE
    Kumar, Bipin
    Patil, Anil Kumar
    Kumar, Manoj
    Jain, Siddharth
    HEAT TRANSFER RESEARCH, 2020, 51 (05) : 395 - 406
  • [45] TiO2/water Nanofluid Heat Transfer in Heat Exchanger Equipped with Double Twisted-Tape Inserts
    Eiamsa-ard, S.
    Ketrain, R.
    Chuwattanakul, V.
    INTERNATIONAL CONFERENCE ON NANOMATERIALS AND BIOMATERIALS (ICNB 2017), 2018, 350
  • [46] Heat transfer performance of a nanofluid-filled tube with wall corrugations and center-cleared twisted-tape inserts
    Mousavi Ajarostaghi, Seyed Soheil
    Shirzad, Mojtaba
    Rashidi, Saman
    Li, Larry K. B.
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2020,
  • [47] Heat transfer enhancement and optimization of a tube fitted with twisted tape in a fin-and-tube heat exchanger
    Zahra Hajabdollahi
    Hassan Hajabdollahi
    Kyung Chun Kim
    Journal of Thermal Analysis and Calorimetry, 2020, 140 : 1015 - 1027
  • [48] Heat transfer enhancement and optimization of a tube fitted with twisted tape in a fin-and-tube heat exchanger
    Hajabdollahi, Zahra
    Hajabdollahi, Hassan
    Kim, Kyung Chun
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2020, 140 (03) : 1015 - 1027
  • [49] Analysis of the flow field, thermal performance, and heat transfer augmentation in circular tube using different dimple geometrical configurations with internal twisted-tape insert
    Al-Obaidi, Ahmed Ramadhan
    HEAT TRANSFER, 2020, 49 (08) : 4153 - 4172
  • [50] Thermo-Hydraulic Performance Analysis on the Effects of Truncated Twisted Tape Inserts in a Tube Heat Exchanger
    Ghalambaz, Mehdi
    Mashayekhi, Ramin
    Arasteh, Hossein
    Ali, Hafiz Muhammad
    Talebizadehsardari, Pouyan
    Yaici, Wahiba
    SYMMETRY-BASEL, 2020, 12 (10): : 1 - 22