Effect of Twin Delta-Winged Twisted-Tape on Thermal Performance of Heat Exchanger Tube

被引:30
|
作者
Eiamsa-Ard, Smith [1 ]
Nuntadusit, Chayut [2 ]
Promvonge, Pongjet [3 ]
机构
[1] Mahanakorn Univ Technol, Dept Mech Engn, Bangkok 10530, Thailand
[2] Prince Songkla Univ, Dept Mech Engn, Hat Yai, Thailand
[3] King Mongkuts Inst Technol Ladkrabang, Fac Engn, Bangkok, Thailand
关键词
FRICTION FACTOR CHARACTERISTICS; TRANSFER ENHANCEMENT; PRESSURE-DROP; LAMINAR-FLOW; SYSTEM;
D O I
10.1080/01457632.2013.793112
中图分类号
O414.1 [热力学];
学科分类号
摘要
This work aims at studying the effect of twin delta-winged twisted-tape insertion on heat transfer, pressure drop, and thermal performance characteristics of a heat exchanger tube. All twisted tapes used in this work were made of aluminum sheets twisted at a single twist ratio of 3.0. The twin delta wings were formed by extrusion of the tape at the center area at every twist length interval. For comparison, three different arrangements of the twin delta wings were: (1) the wing tips pointing upstream of the flow (TTW-up, twin delta-winged twisted tape in counterflow arrangement), (2) the wing tips pointing downstream of the flow (TTW-down, twin delta-winged twisted tape in co-flow arrangement), and (3) the wing tips pointing opposite direction (TTW-o, opposite winged twisted tape). The wing declination was arranged at an angle of 15 degrees with respect to the tape surface. Effects of three different wing-tip angles of 20 degrees, 40 degrees, and 60 degrees for a constant wing base were examined. The experiments were conducted using water as the test fluid in a uniform-heat-flux tube for Reynolds number between 5000 and 15,000. The results demonstrate that the TTW-up consistently provides greater heat transfer rate, friction factor, and thermal performance factor than the TTW-down and the TTW-o, at a similar condition. In addition, the heat transfer rate increases as the wing-tip angle decreases. Over the range investigated, the TTW-up with wing-tip angle of 20 degrees gives the highest thermal performance factor of 1.26 along with a Nusselt number and friction factor of 2.57 and 8.55times those of the plain tube.
引用
收藏
页码:1278 / 1288
页数:11
相关论文
共 50 条
  • [21] Intensification of convective heat transfer and heat exchanger performance by the combined influence of a twisted tube and twisted tape
    Samruaisin, P.
    Kunlabud, S.
    Kunnarak, K.
    Chuwattanakul, V
    Eiamsa-ard, S.
    CASE STUDIES IN THERMAL ENGINEERING, 2019, 14
  • [22] Thermal characteristics in a heat exchanger tube fitted with triple twisted tape inserts
    Bhuiya, M. M. K.
    Chowdhury, M. S. U.
    Shahabuddin, M.
    Saha, M.
    Memon, L. A.
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2013, 48 : 124 - 132
  • [23] Heat conveyance and application in enhancing heat transfer with heat exchanger tubes with twisted-tape insert
    Kong, Songtao
    Dong, Qiwu
    Liu, Minshan
    Jixie Gongcheng Xuebao/Chinese Journal of Mechanical Engineering, 2007, 43 (04): : 83 - 87
  • [24] Performance evaluation of twisted-tape insert induced swirl flow in a laminar thermally developing heat exchanger
    Lim, Kwok Yoong
    Hung, Yew Mun
    Tan, Boon Thong
    APPLIED THERMAL ENGINEERING, 2017, 121 : 652 - 661
  • [25] Thermal characteristics in a heat exchanger tube fitted with dual twisted tape elements in tandem
    Eiamsa-ard, Smith
    Thianpong, Chinaruk
    Eiamsa-ard, Petpices
    Promvonge, Pongjet
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2010, 37 (01) : 39 - 46
  • [26] Heat transfer of orthogonal-mode reciprocating tube fitted with twisted-tape
    Chang, SW
    EXPERIMENTAL HEAT TRANSFER, 2000, 13 (01) : 61 - 86
  • [27] Numerical simulation of fluid flow and heat transfer in tube inserting twisted-tape
    Sun, Dongliang
    Wang, Liangbi
    Huagong Xuebao/Journal of Chemical Industry and Engineering (China), 2004, 55 (09): : 1422 - 1427
  • [28] Experimental evaluation of thermal performance and entropy generation inside a twisted U-tube equipped with twisted-tape inserts
    Feizabadi, A.
    Khoshvaght-Aliabadi, M.
    Rahimi, Asghar B.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2019, 145
  • [29] Performance assessment in a heat exchanger tube fitted with double counter twisted tape inserts
    Bhuiya, M. M. K.
    Sayem, A. S. M.
    Islam, M.
    Chowdhury, M. S. U.
    Shahabuddin, M.
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2014, 50 : 25 - 33
  • [30] Improvement in performance of heat exchanger fitted with twisted tape
    Sivashanmugam, P
    Sundaram, S