Impact of Time Between Collection and Collection Method on Human Tear Fluid Osmolarity

被引:71
作者
Keech, Adam [1 ]
Senchyna, Michelle [2 ]
Jones, Lyndon [1 ]
机构
[1] Univ Waterloo, Ctr Contact Lens Res, Sch Optometry, Waterloo, ON N2L 3G1, Canada
[2] Alcon Res Ltd, Ft Worth, TX USA
关键词
Dry eye; tear film; tear osmolarity; DRY EYE DISEASE; OCULAR SURFACE DISEASE; KERATOCONJUNCTIVITIS SICCA; FILM OSMOLARITY; ELECTRICAL-IMPEDANCE; OSMOTIC-PRESSURE; FLOW-RATE; SYMPTOMS; DIAGNOSIS; TESTS;
D O I
10.3109/02713683.2013.763987
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To generate data on the variability of tear osmolarity in a control (normal, non-dry eye) and symptomatic dry eye population (Ocular Surface Disease Index: OSDI >= 20). A secondary outcome is the determination of the effect that tear collection technique has on the osmolarity of the sample. Materials and methods: This was a two-phase study that recruited 20 subjects (n = 10 normal, n = 10 dry eye) to evaluate the influence of time between measurements (Phase I) and 30 subjects (n = 15 normal, n = 15 dry eye) to evaluate the influence of collection technique (Phase II). As part of Phase I, serial tear osmolarity measurements were performed on each eye; four separated by 15 min followed by four separated by 1 min, at each of three visits. Phase II compared the consecutive measurement of four in vivo tear samples to four in vitro measurements on tears collected and dispensed from a glass capillary tube. Results: During Phase I, the dry eye group had a significantly higher maximum osmolarity (334.2 +/- 25.6mOsm/L) compared to the normal group (304.0 +/- 8.4 mOsm/L, p = 0.002). No significant differences were observed whether collections were performed at 15 or 1 min intervals. During Phase II, the in vivo osmolarity was equivalent to in vitro measurements from glass capillary tube samples for both the dry eye group (323.0 +/- 16.7mOsm/L versus 317.7 +/- 24.8, p = 0.496), and for the normal subjects (301.2 +/- 7.2mOsm/L versus 301.9 +/- 16.0 mOsm/L, p = 0.884). Conclusion: Symptomatic dry eye subjects exhibited a significantly higher tear osmolarity and variation over time than observed in normal subjects, reflecting the inherent tear film instability of dry eye disease. There was no change in the distribution of tear osmolarity measurements whether tears were collected in rapid succession or given time to equilibrate, and collection method had no impact on tear osmolarity.
引用
收藏
页码:428 / 436
页数:9
相关论文
共 42 条
[1]  
Anagnoste S. R., 1996, Investigative Ophthalmology and Visual Science, V37, pS852
[3]   Tear osmolarity measurement using the TearLab™ Osmolarity System in the assessment of dry eye treatment effectiveness [J].
Benelli, Umberto ;
Nardi, Marco ;
Posarelli, Chiara ;
Albert, Timothy G. .
CONTACT LENS & ANTERIOR EYE, 2010, 33 (02) :61-67
[4]  
Benjamin W J, 1983, J Am Optom Assoc, V54, P243
[5]   TEAR OSMOTIC DIFFERENCES ACROSS THE OCULAR SURFACE [J].
BENJAMIN, WJ ;
HILL, RM .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1986, 224 (06) :583-586
[6]  
BENJAMIN WJ, 1983, INVEST OPHTH VIS SCI, V24, P1624
[7]  
Bergmanson JP, 2000, OPTOMETRY VISION SCI, V77, P265
[8]   Reproducibility and repeatability of the OcuSense TearLab™ osmometer [J].
Eperjesi, Frank ;
Aujla, Maana ;
Bartlett, Hannah .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 250 (08) :1201-1205
[9]  
Farris R L, 1986, Trans Am Ophthalmol Soc, V84, P250
[10]  
Farris R L, 1985, Trans Am Ophthalmol Soc, V83, P501