Rapid pulmonary vein isolation utilizing the third-generation laserballoon - The PhoeniX registry

被引:27
作者
Heeger, Christian-H [1 ,2 ]
Tiemeyer, Christian M. [1 ]
Phan, Huong-Lan [1 ]
Meyer-Saraei, Roza [1 ]
Fink, Thomas [1 ]
Sciacca, Vanessa [1 ]
Liosis, Spyridon [1 ]
Brueggemann, Ben [1 ]
Grosse, Niels [1 ]
Fahimi, Bezhad [1 ]
Reincke, Samuel [1 ]
Kuck, Karl-Heinz [1 ,3 ]
Ouyang, Feifan [4 ]
Vogler, Julia [1 ]
Eitel, Charlotte [1 ]
Tilz, Roland R. [1 ,2 ]
机构
[1] Univ Hosp Schleswig Holstein, Univ Heart Ctr Lubeck, Med Clin 2, Div Electrophysiol,Dept Cardiol Angiol & Intens C, Lubeck, Germany
[2] German Ctr Cardiovasc Res DZHK, Partner Site Hamburg Kiel Lubeck, Lubeck, Germany
[3] LANS Cardio, Stephanspl 5, D-20354 Hamburg, Germany
[4] Fuwai Hosp, Natl Ctr Cardiovasc Dis, Beijing, Peoples R China
来源
IJC HEART & VASCULATURE | 2020年 / 29卷
关键词
Atrial fibrillation; Catheter ablation; Endoscopic ablation; Laser balloon; Pulmonary vein isolation; GUIDED LASER BALLOON; RADIOFREQUENCY ABLATION; MULTICENTER; CRYOBALLOON; CATHETER; EFFICACY; SAFETY;
D O I
10.1016/j.ijcha.2020.100576
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Balloon-based ablation systems for pulmonary vein isolation (PVI) are providing procedural safety and efficacy as well as favourable clinical outcome. Although second-generation laser balloon (LB2) based PVI has been shown safety and efficacy relatively long procedural duration was a strong limitation. The third-generation laser balloon (LB3) offers and automized ablation for rapid PVI. We determined safety, efficacy and procedural characteristics of this new promising ablation system. Methods and results: A total of 15 consecutive patients were prospectively enrolled. All patients underwent PVI using the LB3. A total 59/59 PVs (100%) were successfully isolated. Procedural data was compared to the last 15 consecutive patients treated by the LB2. The median procedure time significantly declined from LB2 (91 (86, 105) min) to LB3 (77 (68, 87) min), p < 0.001. Similarly, the median left atrial dwelling time significantly decreased from LB2 (72 (62, 84) min) to LB3 (45 (38, 52) min), p < 0.0001. The total laser time decreased from LB2 (1920 (1765, 2193) sec) to LB3 (1077 (896, 1165) sec), p < 0.00001. A pure single shot PVI was performed in 18/59 PVs (31%). For major adverse events no differences were detected between the groups (LB2 1/15 (6.7%) and LB3 1/15 (6.7%), p = 0.999). Conclusion: The LB3 was safe and effective for PVI. Procedure time, LA dwelling time and total laser time significantly decreased compared to LB2. (C) 2020 The Author(s). Published by Elsevier B.V.
引用
收藏
页数:6
相关论文
共 21 条
[1]   Energy titration strategies with the endoscopic ablation system: lessons from the high-dose vs. low-dose laser ablation study [J].
Bordignon, Stefano ;
Chun, Kyoung-Ryul Julian ;
Gunawardene, Melanie ;
Urban, Verena ;
Kulikoglu, Mehmet ;
Miehm, Kristin ;
Brzank, Beate ;
Schulte-Hahn, Britta ;
Nowak, Bernd ;
Schmidt, Boris .
EUROPACE, 2013, 15 (05) :685-689
[2]   Individualized cryoballoon energy pulmonary vein isolation guided by real-time pulmonary vein recordings, the randomized ICE-Ttrial [J].
Chun, K. R. Julian ;
Stich, Marie ;
Fuernkranz, Alexander ;
Bordignon, Stefano ;
Perrotta, Laura ;
Dugo, Daniela ;
Bologna, Fabrizio ;
Schmidt, Boris .
HEART RHYTHM, 2017, 14 (04) :495-500
[3]   Pulmonary Vein Isolation Using the Visually Guided Laser Balloon A Prospective, Multicenter, and Randomized Comparison to Standard Radiofrequency Ablation [J].
Dukkipati, Srinivas R. ;
Cuoco, Frank ;
Kutinsky, Ilana ;
Aryana, Arash ;
Bahnson, Tristram D. ;
Lakkireddy, Dhanunjaya ;
Woollett, Ian ;
Issa, Ziad F. ;
Natale, Andrea ;
Reddy, Vivek Y. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (12) :1350-1360
[4]   Pulmonary Vein Isolation Using a Visually Guided Laser Balloon Catheter: The First 200-Patient Multicenter Clinical Experience [J].
Dukkipati, Srinivas R. ;
Kuck, Karl-Heinz ;
Neuzil, Petr ;
Woollett, Ian ;
Kautzner, Josef ;
McElderry, H. Thomas ;
Schmidt, Boris ;
Gerstenfeld, Edward P. ;
Doshi, Shephal K. ;
Horton, Rodney ;
Metzner, Andreas ;
d'Avila, Andre ;
Ruskin, Jeremy N. ;
Natale, Andrea ;
Reddy, Vivek Y. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2013, 6 (03) :467-472
[5]   The durability of pulmonary vein isolation using the visually guided laser balloon catheter: Multicenter results of pulmonary vein remapping studies [J].
Dukkipati, Srinivas R. ;
Neuzil, Petr ;
Kautzner, Josef ;
Petru, Jan ;
Wichterle, Dan ;
Skoda, Jan ;
Cihak, Robert ;
Peichl, Petr ;
Dello Russo, Antonio ;
Pelargonio, Gemma ;
Tondo, Claudio ;
Natale, Andrea ;
Reddy, Vivek Y. .
HEART RHYTHM, 2012, 9 (06) :919-925
[6]   Second-Generation Visually Guided Laser Balloon Ablation System for Pulmonary Vein Isolation: Learning Curve, Safety and Efficacy - The MERLIN Registry - [J].
Heeger, Christian-H. ;
Phan, Huong-Lan ;
Meyer-Saraei, Roza ;
Fink, Thomas ;
Sciacca, Vanessa ;
Liosis, Spyridon ;
Brueggemann, Ben ;
Grosse, Niels ;
Fahimi, Bezhad ;
Sano, Makoto ;
Kuck, Karl-Heinz ;
Ouyang, Feifan ;
Vogler, Julia ;
Eitel, Charlotte ;
Tilz, Roland Richard .
CIRCULATION JOURNAL, 2019, 83 (12) :2443-2451
[7]   Three-Year Clinical Outcome After 2nd-Generation Cryoballoon-Based Pulmonary Vein Isolation for the Treatment of Paroxysmal and Persistent Atrial Fibrillation - A 2-Center Experience - [J].
Heeger, Christian-H. ;
Wissner, Erik ;
Knoell, Milena ;
Knoop, Benedikt ;
Reissmann, Bruno ;
Mathew, Shibu ;
Sohns, Christian ;
Lemes, Christine ;
Maurer, Tilman ;
Santoro, Francesco ;
Riedl, Johannes ;
Inaba, Osamu ;
Fink, Thomas ;
Rottner, Laura ;
Wohlmuth, Peter ;
Goldmann, Britta ;
Ouyang, Feifan ;
Kuck, Karl-Heinz ;
Metzner, Andreas .
CIRCULATION JOURNAL, 2017, 81 (07) :974-980
[8]   Reconduction After Second-Generation Cryoballoon-Based Pulmonary Vein Isolation - Impact of Different Ablation Strategies - [J].
Heeger, Christian-Hendrik ;
Rexha, Enida ;
Maack, Sabrina ;
Rottner, Laura ;
Fink, Thomas ;
Mathew, Shibu ;
Maurer, Tilman ;
Lemes, Christine ;
Rillig, Andreas ;
Wohlmuth, Peter ;
Reissmann, Bruno ;
Tilz, Roland Richard ;
Ouyang, Feifan ;
Kuck, Karl-Heinz ;
Metzner, Andreas .
CIRCULATION JOURNAL, 2020, 84 (06) :902-910
[9]   Efficacy and Safety of Cryoballoon Ablation in Patients With Heart Failure and Reduced Left Ventricular Ejection Fraction A Multicenter Study [J].
Heeger, Christian-Hendrik ;
Abdin, Amr ;
Mathew, Shibu ;
Reissmann, Bruno ;
Yalin, Kivanc ;
Liosis, Spyridon ;
Fink, Thomas ;
Proietti, Riccardo ;
Eitel, Charlotte ;
Vogler, Julia ;
Lemes, Christine ;
Maurer, Tilman ;
Rillig, Andreas ;
Meyer-Saraei, Roza ;
Graf, Tobias ;
Wohlmuth, Peter ;
Goldmann, Britta ;
Ouyang, Feifan ;
Kuck, Karl-Heinz ;
Metzner, Andreas ;
Tilz, Roland Richard .
CIRCULATION JOURNAL, 2019, 83 (08) :1653-1659
[10]   2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS [J].
Kirchhof, Paulus ;
Benussi, Stefano ;
Kotecha, Dipak ;
Ahlsson, Anders ;
Atar, Dan ;
Casadei, Barbara ;
Castella, Manuel ;
Diener, Hans-Christoph ;
Heidbuchel, Hein ;
Hendriks, Jeroen ;
Hindricks, Gerhard ;
Manolis, Antonis S. ;
Oldgren, Jonas ;
Popescu, Bogdan Alexandru ;
Schotten, Ulrich ;
Van Putte, Bart ;
Vardas, Panagiotis .
EUROPEAN HEART JOURNAL, 2016, 37 (38) :2893-+