Experimental research on dynamic characteristics and control strategy of the pump-driven two-phase loop with dual evaporators

被引:12
作者
Zhang, Penglei [1 ,2 ]
Liu, Kehan [1 ]
Li, Yue [1 ]
Yang, Xiaorui [1 ]
Li, Xiaolin [1 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Inst Air Conditioning & Refrigerat, Coll Aerosp Engn, Nanjing 210016, Peoples R China
[2] Nanjing Univ Aeronaut & Astronaut, Inst Air Conditioning & Refrigerat, Nanjing 210016, Peoples R China
基金
中国国家自然科学基金;
关键词
Pump -driven two-phase loop; Dual evaporators; Control strategy; Thermal management; Experiment; COOLING SYSTEM; PERFORMANCE; FLOW; THERMOSIPHON;
D O I
10.1016/j.csite.2022.102327
中图分类号
O414.1 [热力学];
学科分类号
摘要
The pump-driven two-phase loop is a promising thermal management technology for avionics, but its dynamic characteristics and control strategy are not clear. A prototype of a pump-driven two-phase loop with a single/dual evaporator for cooling of avionics was developed and its dynamic characteristic under different heat loads and flow rates were studied. It was found that after the evaporator outlet reached saturation, increasing the flow rate would instead reduce the performance, due to the increasing flow resistance of the gas tube and pump power consumption. Based on this, a control strategy of controlling the vapor quality at the evaporator outlet to 0.9-0.95, by adjusting the speed of the pump, was proposed and verified under dynamic heat loads. The results showed that this control strategy ensured optimal system heat transfer performance while reduced the power consumption of the pump. In the experiments of the pumpdriven two-phase loop with dual evaporators, it was found that the branch with the larger heat load had a lower flow rate, and was more likely to be superheated. Therefore, in the control of a pump-driven two-phase loop with multiple evaporators, the branch with the maximum heat load should be taken as the control object.
引用
收藏
页数:15
相关论文
共 38 条
[1]  
Asias A., 2007, INSTABILITY HEAT PIP
[2]   Experimental analysis of pump-assisted and capillary-driven dual-evaporators two-phase cooling loop [J].
Crepinsek, Michael ;
Park, Chanwoo .
APPLIED THERMAL ENGINEERING, 2012, 38 :133-142
[3]   Startup regimes of minichannel evaporator in a mechanically pumped fluid loop [J].
Deng, Zilong ;
Zhang, Jie ;
Lei, Youjie ;
Tao, Jianyun ;
Zhang, Chengbin .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2021, 176
[4]   A review of two-phase submerged boiling in thermal management of electronic cooling [J].
Fan, Simiao ;
Duan, Fei .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 150
[5]  
Fang Y., 2020, ENERGY REP
[6]   STRUCTURES OF VERY HIGH THERMAL CONDUCTANCE [J].
GROVER, GM ;
ERICKSON, GF ;
COTTER, TP .
JOURNAL OF APPLIED PHYSICS, 1964, 35 (06) :1990-&
[7]   Condensation of R407C in a horizontal microfin tube [J].
Honda, H ;
Wijayantab, AT ;
Takata, N .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (02) :203-211
[8]   Experimental investigation on a mechanically pumped two-phase cooling loop with dual-evaporator [J].
Jie, Liu ;
Nian-Qiang, Pei ;
Kai-Hua, Guo ;
Zhen-Hui, He ;
Ting-Xuen, Li .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (07) :1176-1182
[9]   Thermal performance of a novel flat thermosyphon for avionics thermal management [J].
Junior, Antonio A. M. ;
Mantelli, Marcia B. H. .
ENERGY CONVERSION AND MANAGEMENT, 2019, 202
[10]   Heat transfer in the evaporator of an advanced two-phase thermosyphon loop [J].
Khodabandeh, R .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (02) :190-202