The carbon paste electrode encrusted with a microreactor as glucose biosensor

被引:38
作者
Kulys, J [1 ]
机构
[1] Inst Biochem, Lab Enzyme Chem, LT-2600 Vilnius, Lithuania
关键词
biosensor; glucose oxidase; glucose; carbon paste electrode; mediator;
D O I
10.1016/S0956-5663(99)00026-3
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The amperometric biosensors based on carbon paste electrodes (CPEs) encrusted with single microreactor (MR) have been constructed for the determination of glucose. The MRs were prepared from CPC-silica carrier (CPC) and were loaded with glucose oxidase (GO), mediator (M) and acceptor (A). As the mediator cation radical of 5,10-dimethyl-5,10-dihydrophenazine (DMDHP), N-methylphenazonium methyl sulfate (PMS) and o-benzoquinone (BQ) and as the acceptor Fe[EDTA]- or Fe(CN)(6)(3-) was used.. The biosensors acted at electrode potential 0.15-0.27 V versus Ag-AgCl electrode. The calibration graphs of the biosensors were linear in the range from 1.5 to 50 mM of glucose. The sensitivity of the biosensors did not change at pH 6-8. The dissolved oxygen little (7%) influenced the biosensors response and 1 mM of ascorbic acid produced the response that was of equal value to 0.5 mM of glucose. The biosensors showed high stability; no change of the response of the biosensors prepared by using the novel microreactor was observed at least for 6 months by keeping the loaded CPC at room temperature in silica container. An optimization of the biosensors response against the GO, the mediator and the polymer amount was performed. The digital modeling of the biosensors action is following. (C) 1999 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:473 / 479
页数:7
相关论文
共 17 条
[1]   LONG-TERM OPERATIONAL STABILITY OF A MIXED GLUCOSE OXIDASE-REDOX MEDIATOR-CARBON PASTE ELECTRODE [J].
AMINE, A ;
KAUFFMANN, JM ;
PATRIARCHE, GJ ;
KAIFER, AE .
ANALYTICAL LETTERS, 1991, 24 (08) :1293-1315
[2]   CHARACTERIZATION OF MIXED ENZYME-MEDIATOR-CARBON PASTE ELECTRODES [J].
AMINE, A ;
KAUFFMANN, JM ;
GUILBAULT, GG ;
BACHA, S .
ANALYTICAL LETTERS, 1993, 26 (07) :1281-1299
[3]   AMPEROMETRIC GLUCOSE SENSORS BASED ON FERROCENE-MODIFIED POLY(ETHYLENE OXIDE) AND GLUCOSE-OXIDASE [J].
HALE, PD ;
LAN, HL ;
BOGUSLAVSKY, LI ;
KARAN, HI ;
OKAMOTO, Y ;
SKOTHEIM, TA .
ANALYTICA CHIMICA ACTA, 1991, 251 (1-2) :121-128
[4]   LONG-TERM RESPONSE OF AN INTEGRATED CARBON-PASTE BASED GLUCOSE BIOSENSOR [J].
KULYS, J ;
HANSEN, HE .
ANALYTICA CHIMICA ACTA, 1995, 303 (2-3) :285-294
[5]   METHYLENE-GREEN-MEDIATED CARBON-PASTE GLUCOSE BIOSENSOR [J].
KULYS, J ;
WANG, L ;
HANSEN, HE ;
BUCHRASMUSSEN, T ;
WANG, J ;
OZSOZ, M .
ELECTROANALYSIS, 1995, 7 (01) :92-94
[6]  
Kulys J, 1998, ANAL LETT, V31, P569, DOI 10.1080/00032719808001862
[7]   CARBON-PASTE BIOSENSORS ARRAY FOR LONG-TERM GLUCOSE MEASUREMENT [J].
KULYS, J ;
HANSEN, HE .
BIOSENSORS & BIOELECTRONICS, 1994, 9 (07) :491-500
[8]   GLUCOSE BIOSENSOR BASED ON THE INCORPORATION OF MELDOLA BLUE AND GLUCOSE-OXIDASE WITHIN CARBON-PASTE [J].
KULYS, J ;
HANSEN, HE ;
BUCHRASMUSSEN, T ;
WANG, J ;
OZSOZ, M .
ANALYTICA CHIMICA ACTA, 1994, 288 (03) :193-196
[9]   THE PREPARATION IN-SITU OF A SILVER SILVER-CHLORIDE REFERENCE ELECTRODE [J].
KULYS, J ;
MUNK, JA ;
BUCHRASMUSSEN, T ;
HANSEN, HE .
ELECTROANALYSIS, 1994, 6 (11-12) :945-952
[10]  
KULYS JJ, 1983, BIOCHIM BIOPHYS ACTA, V744, P57, DOI 10.1016/0167-4838(83)90340-0