Polypyrrole/copper hexacyanoferrate hybrid as redox mediator for glucose biosensors

被引:73
作者
Fiorito, PA
Brett, CMA
de Torresi, SIC
机构
[1] Univ Sao Paulo, Inst Quim, BR-05513970 Sao Paulo, Brazil
[2] Univ Coimbra, Dept Quim, P-3004535 Coimbra, Portugal
基金
巴西圣保罗研究基金会;
关键词
Prussian Blue analogues; polypyrrole; hybrid materials; glucose biosensors;
D O I
10.1016/j.talanta.2005.09.040
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A copper containing Prussian Blue analogue was incorporated into a conducting polypyrrole film. The modified electrode was synthesized through an electrochemical two-step methodology leading to very stable and homogeneous hybrid films. These electrodes were proved to show excellent catalytic properties towards H2O2 detection, with a performance higher than those observed for Prussian Blue and other analogues. Electrochemical impedance spectroscopy experiments demonstrated that the excellent performance of these hybrid films is strongly related to the electronic conductivity of the polymeric matrix that is wiring the copper hexacyanoferrate sites. A glucose biosensor was built-up by the immobilization of glucose oxidase; the sensitivity obtained being higher than other biosensors reported in the literature even in Na+ containing electrolytes. (C) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:403 / 408
页数:6
相关论文
共 34 条
[1]   POLYNUCLEAR NICKEL HEXACYANOFERRATES - MONITORING OF FILM GROWTH AND HYDRATED COUNTER-CATION FLUX STORAGE DURING REDOX REACTIONS [J].
BACSKAI, J ;
MARTINUSZ, K ;
CZIROK, E ;
INZELT, G ;
KULESZA, PJ ;
MALIK, MA .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 385 (02) :241-248
[2]   Amperometric biosensor for ethanol based on immobilization of alcohol dehydrogenase on a nickel hexacyanoferrate modified microband gold electrode [J].
Cai, CX ;
Xue, KH ;
Zhou, YM ;
Yang, H .
TALANTA, 1997, 44 (03) :339-347
[3]   Preparation, characterization, and electrocatalytic properties of copper hexacyanoferrate film and bilayer film modified electrodes [J].
Chen, SM ;
Chan, CM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2003, 543 (02) :161-173
[4]   Preparation, characterization, and electrocatalytic oxidation properties of iron, cobalt, nickel, and indium hexacyanoferrate [J].
Chen, SM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2002, 521 (1-2) :29-52
[5]   A glucose biosensor based on enzyme entrapment within polypyrrole films electrodeposited on mesoporous titanium dioxide [J].
Cosnier, S ;
Senillou, A ;
Grätzel, M ;
Comte, P ;
Vlachopoulos, N ;
Renault, NJ ;
Martelet, C .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 469 (02) :176-181
[6]  
De Mattos IL, 2001, QUIM NOVA, p200e5
[8]   Enzyme-mediated amperometric biosensors prepared with the Layer-by-Layer (LbL) adsorption technique [J].
Ferreira, M ;
Fiorito, PA ;
Oliveira, ON ;
de Torresi, SIC .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (12) :1611-1615
[9]   Hybrid nickel hexacyanoferrate/polypyrrole composite as mediator for hydrogen peroxide detection and its application in oxidase-based biosensors [J].
Fiorito, PA ;
de Torresi, SIC .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2005, 581 (01) :31-37
[10]  
Fiorito PA, 2001, J BRAZIL CHEM SOC, V12, P729