Combination Evaluation of Preoperative Risk Indices Predicts Requirement of Biventricular Assist Device

被引:41
作者
Shiga, Taro
Kinugawa, Koichiro [1 ]
Imamura, Teruhiko
Kato, Naoko
Endo, Miyoko [2 ]
Inaba, Toshiro
Maki, Hisataka
Hatano, Masaru
Yao, Atsushi
Nishimura, Takashi [4 ]
Hirata, Yasunobu
Kyo, Shunei [4 ]
Ono, Minoru [3 ]
Nagai, Ryozo
机构
[1] Tokyo Univ Hosp, Dept Cardiovasc Med, Bunkyo Ku, Tokyo 1138655, Japan
[2] Tokyo Univ Hosp, Dept Organ Transplantat, Tokyo 1138655, Japan
[3] Tokyo Univ Hosp, Dept Cardiothorac Surg, Tokyo 1138655, Japan
[4] Univ Tokyo, Dept Therapeut Strategy Heart Failure, Grad Sch Med, Tokyo, Japan
基金
日本学术振兴会;
关键词
Heart failure; Right ventricular dysfunction; Stage D; Transplantation; RIGHT-VENTRICULAR FAILURE; HEART-FAILURE; SUPPORT; IMPLANTATION; SCORE; NEED;
D O I
10.1253/circj.CJ-12-0231
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Patients with biventricular assist device (BiVAD) placement have a poor prognosis, but preoperative risk factors for the necessity of BiVAD have not been fully elucidated. Methods and Results: Data from 79 patients who received left ventricular assist device (LVAD) between November 2002 and December 2011 were retrospectively reviewed. Overall, 9 patients (11.4%) required BiVAD, and the survival rate of BiVAD patients was significantly lower than that of LVAD patients (P<0.001). Multivariate analysis for BiVAD requirement showed left ventricular diastolic diameter (LVDd) <= 62 mm (odds ratio [OR], 10.97; P=0.009) to be significantly associated with BiVAD requirement. Preoperative central venous pressure (CVP)/pulmonary capillary wedge pressure (PCWP) ratio >= 0.5 (OR, 13.09; P=0.028) was also significantly associated with BiVAD requirement. A new scoring system for predicting BiVAD requirement was created from the combination of CVP/PCWP ratio >= 0.5), body surface area (<= 1.4m(2)), preoperative continuous hemodiafiltration use, B-type natriuretic peptide (>= 1,200 pg/ml) and LVDd (562 mm), and this had a significantly larger area under the curve (0.909; P=0.003) than right ventricular stroke work index on receiver operating characteristic analysis. A score >20 using the new scoring method indicated significantly high probability of BiVAD requirement (OR, 16.00; P=0.019). Conclusions: The new scoring method, which includes CVP/PCWP ratio, is a novel risk stratification tool for BiVAD therapy. (Circ J 2012; 76: 2785-2791)
引用
收藏
页码:2785 / 2791
页数:7
相关论文
共 20 条
[1]   Survival after biventricular assist device implantation: An analysis of the Interagency Registry for Mechanically Assisted Circulatory Support database [J].
Cleveland, Joseph C., Jr. ;
Naftel, David C. ;
Reece, T. Brett ;
Murray, Margaret ;
Antaki, James ;
Pagani, Francis D. ;
Kirklin, James K. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2011, 30 (08) :862-869
[2]  
Dang NC, 2006, J HEART LUNG TRANSPL, V25, P1, DOI 10.1016/j.healun.2005.07.008
[3]   Early planned institution of biventricular mechanical circulatory support results in improved outcomes compared with delayed conversion of a left ventricular assist device to a biventricular assist device [J].
Fitzpatrick, J. Raymond, III ;
Frederick, John R. ;
Hiesinger, William ;
Hsu, Vivian M. ;
McCormick, Ryan C. ;
Kozin, Elliott D. ;
Laporte, Carine M. ;
O'Hara, Mary Lou ;
Howell, Elan ;
Dougherty, Deborah ;
Cohen, Jeffrey E. ;
Southerland, Kevin W. ;
Howard, Jessica L. ;
Paulson, Carter ;
Acker, Michael A. ;
Morris, Rohinton J. ;
Woo, Y. Joseph .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (04) :971-977
[4]   Risk Score Derived from Pre-operative Data Analysis Predicts the Need for Biventricular Mechanical Circulatory Support [J].
Fitzpatrick, J. Raymond, III ;
Frederick, John R. ;
Hsu, Vivian M. ;
Kozin, Elliott D. ;
O'Hara, Mary Lou ;
Howell, Elan ;
Dougherty, Deborah ;
McCormick, Ryan C. ;
Laporte, Carine A. ;
Cohen, Jeffrey E. ;
Southerland, Kevin W. ;
Howard, Jessica L. ;
Jessup, Mariell L. ;
Morris, Rohinton J. ;
Acker, Michael A. ;
Woo, Y. Joseph .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2008, 27 (12) :1286-1292
[5]   Preoperative risk factors for right ventricular failure after implantable left ventricular assist device insertion [J].
Fukamachi, K ;
McCarthy, PM ;
Smedira, NG ;
Vargo, RL ;
Starling, RC ;
Young, JB .
ANNALS OF THORACIC SURGERY, 1999, 68 (06) :2181-2184
[6]   Right ventricular dysfunction and organ failure in left ventricular assist device recipients: A continuing problem [J].
Kavarana, MN ;
Pessin-Minsley, MS ;
Urtecho, J ;
Catanese, KA ;
Flannery, M ;
Oz, MC ;
Naka, Y .
ANNALS OF THORACIC SURGERY, 2002, 73 (03) :745-750
[7]   How to Treat Stage D Heart Failure? - When to Implant Left Ventricular Assist Devices in the Era of Continuous Flow Pumps? - [J].
Kinugawa, Koichiro .
CIRCULATION JOURNAL, 2011, 75 (09) :2038-2045
[8]   The Fourth INTERMACS Annual Report: 4,000 implants and counting [J].
Kirklin, James K. ;
Naftel, David C. ;
Kormos, Robert L. ;
Stevenson, Lynne W. ;
Pagani, Francis D. ;
Miller, Marissa A. ;
Baldwin, J. Timothy ;
Young, James B. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2012, 31 (02) :117-126
[9]   Transplant candidate's clinical status rather than right ventricular function defines need for univentricular versus biventricular support [J].
Kormos, RL ;
Gasior, TA ;
Kawai, A ;
Pham, SM ;
Murali, S ;
Hattler, BG ;
Griffith, BP .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 111 (04) :773-783
[10]   Right ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: Incidence, risk factors, and effect on outcomes [J].
Kormos, Robert L. ;
Teuteberg, Jeffrey J. ;
Pagani, Francis D. ;
Russell, Stuart D. ;
John, Ranjit ;
Miller, Leslie W. ;
Massey, Todd ;
Milano, Carmelo A. ;
Moazami, Nader ;
Sundareswaran, Kartik S. ;
Farrar, David J. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 139 (05) :1316-1324