Design and Performance Study of a Novel Refrigeration System

被引:0
|
作者
Liu Yanling [1 ,2 ]
Wang Lingqun [1 ]
Xia Zaizhong [3 ]
机构
[1] Shanghai Ocean Univ, Refrigerat & Air Cond Engn, Shanghai, Peoples R China
[2] Shanghai Ocean Univ, Coll Informat Technol, Shanghai, Peoples R China
[3] Shanghai Jiao Tong Univ, Inst Refrigerat & Cryogen, Shanghai, Peoples R China
关键词
Adsorption refrigeration; Water chiller; Heat recovery; Mass recovery-like; Silica gel; ADSORPTION COOLING SYSTEM; CHILLER; SIMULATION; CYCLE; COP;
D O I
10.4028/www.scientific.net/AMR.354-355.819
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In order to solve the problems of pressure drop and leakage in the refrigerant circuit, a novel continuous adsorption system suited to use low heat source (75-85 degrees C) was designed and set up. To analyze and compare with the conventional system to reveal the similarity and difference, this paper sets up the mathematical models for these two systems. The adsorbers, condensers and evaporators in these two systems are exactly the same and the two systems are compared by working at the identical conditions, which is not feasible in real experimental lab. All the parameters and models used in this calculation are based on experimental results. Analysis demonstrates that the two kinds of system have very close performances, that is, the novel system has a relatively higher cooling capacity while the conventional system has a relatively higher COP.
引用
收藏
页码:819 / +
页数:2
相关论文
共 50 条
  • [31] STUDY OF THE PERFORMANCE COEFFICIENT OF AN ACTIVE MAGNETIC REGENERATIVE REFRIGERATION SYSTEM
    Meddeb, Z.
    Bchiri, D.
    Sidhom, R.
    Chrigui, M.
    Jeday, M. R.
    7TH INTERNATIONAL CONFERENCE ON MAGNETIC REFRIGERATION AT ROOM TEMPERATURE, 2016, : 51 - 54
  • [32] On the choice of performance assessment criteria and their impact on the overall system performance - The refrigeration system case study
    Green, Torben
    Izadi-Zamanabadi, Roozbeh
    Niemann, Henrik
    2010 CONFERENCE ON CONTROL AND FAULT-TOLERANT SYSTEMS (SYSTOL'10), 2010, : 624 - 629
  • [33] Design and performance analysis of two-stage ejector for the subzero refrigeration system
    Song Y.
    Wang X.
    Wang L.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2022, 43 (09): : 34 - 43
  • [34] Numerical Study of Cyclic Performance and Design of a Novel Fan Bracing System
    Aval, Seyed Bahram Beheshti
    Ghayoumi, Saba
    Hajirasouliha, Iman
    JOURNAL OF EARTHQUAKE ENGINEERING, 2022, 26 (12) : 6494 - 6523
  • [35] Design and realization of virtual instrumentation test system for the performance of refrigeration air conditioning
    Qiao, JY
    Panxuhua
    Shen, J
    Li, XM
    ICEMI 2005: Conference Proceedings of the Seventh International Conference on Electronic Measurement & Instruments, Vol 6, 2005, : 664 - 669
  • [36] Design and Performance Analysis of a Biodiesel Engine Driven Refrigeration System for Vaccine Storage
    Kamsuk, W.
    Damrongsak, D.
    Tippayawong, N.
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY DEVELOPMENT-IJRED, 2013, 2 (02): : 117 - 124
  • [37] Design and Performance of Solar PV Integrated Domestic Vapor Absorption Refrigeration System
    Selvaraj, Divya Arputham
    Victor, Kirubakaran
    INTERNATIONAL JOURNAL OF PHOTOENERGY, 2021, 2021
  • [38] Thermal Performance Evaluation of a Novel Ejector-Injection Cascade Refrigeration System
    Faruque, Md Walid
    Khan, Yasin
    Nabil, Mahdi Hafiz
    Ehsan, M. Monjurul
    Karim, Azharul
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2023, 39
  • [39] Comparative performance study and advanced exergy analysis of novel vapor compression-absorption integrated refrigeration system
    Jain, Vaibhav
    Sachdeva, Gulshan
    Kachhwaha, S. S.
    ENERGY CONVERSION AND MANAGEMENT, 2018, 172 : 81 - 97
  • [40] Design and performance analysis of LiBr refrigeration-heat pump system applied in CCHP system
    Zhang, Cuizhen
    Yang, Mo
    Lu, Mei
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2011, 32 (12): : 1816 - 1821