Concurrent validity and reliability of wireless instrumented insoles measuring postural balance and temporal gait parameters

被引:36
|
作者
Oerbekke, Michiel S. [1 ,2 ]
Stukstette, Mirelle J. [1 ,2 ]
Schutte, Kurt [3 ,4 ]
de Bie, Rob A. [5 ]
Pisters, Martijn F. [1 ,2 ,6 ]
Vanwanseele, Benedicte [3 ,6 ]
机构
[1] Univ Med Ctr Utrecht, Dept Rehabil Nursing Sci & Sport, Brain Ctr Rudolf Magnus, Phys Therapy Res, Utrecht, Netherlands
[2] Julius Hlth Care Centers, Ctr Phys Therapy Res & Innovat Primary Care, Utrecht, Netherlands
[3] Katholieke Univ Leuven, Fac Kinesiol & Rehabil Sci, Dept Kinesiol, Leuven, Belgium
[4] Univ Stellenbosch, Dept Sport Sci, Stellenbosch, South Africa
[5] Maastricht Univ, CAPHRI Sch Publ Hlth & Primary Care, Dept Epidemiol, Maastricht, Netherlands
[6] Fontys Univ Appl Sci, Dept Hlth Innovat & Technol, Eindhoven, Netherlands
关键词
Center of pressure; Spatiotemporal; Gait; Instrumented insoles; HIP OSTEOARTHRITIS; PLANTAR PRESSURE; METAANALYSIS; SYSTEM; KNEE; AGREEMENT; WALKING; FOOT;
D O I
10.1016/j.gaitpost.2016.10.005
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: The OpenGo seems promising to take gait analysis out of laboratory settings due to its capability of long-term measurements and mobility. However, the OpenGo's concurrent validity and reliability need to be assessed to determine if the instrument is suitable for validation in patient samples. Methods: Twenty healthy volunteers participated. Center of pressure data were collected under eyes open and closed conditions with participants performing unilateral stance trials on the gold standard (AMTI OR6-7 force plate) while wearing the OpenGo. Temporal gait data (stance time, gait cycle time, and cadence) were collected at a self-selected comfortable walking speed with participants performing test-retest trials on an instrumented treadmill while wearing the OpenGo. Validity was assessed using Bland-Altman plots. Reliability was assessed with Intraclass Correlation Coefficient (2,1) and smallest detectable changes were calculated. Findings: Negative means of differences were found in all measured parameters, illustrating lower scores for the OpenGo on average. The OpenGo showed negative upper limits of agreement in center of pressure parameters on the mediolateral axis. Temporal reliability ICCs ranged from 0.90-0.93. Smallest detectable changes for both stance times were 0.04 (left) and 0.05 (right) seconds, for gait cycle time 0.08 s, and for cadence 4.5 steps per minute. Interpretation: The OpenGo is valid and reliable for the measurement of temporal gait parameters during walking. Measurements of center of pressure parameters during unilateral stance are not considered valid. The OpenGo seems a promising instrument for clinically screening and monitoring temporal gait parameters in patients, however validation in patient populations is needed. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:116 / 124
页数:9
相关论文
共 50 条
  • [31] Concurrent validity of human pose tracking in video for measuring gait parameters in older adults: a preliminary analysis with multiple trackers, viewing angles, and walking directions
    Mehdizadeh, Sina
    Nabavi, Hoda
    Sabo, Andrea
    Arora, Twinkle
    Iaboni, Andrea
    Taati, Babak
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2021, 18 (01)
  • [32] Quantifying Spatiotemporal Gait Parameters with HoloLens in Healthy Adults and People with Parkinson's Disease: Test-Retest Reliability, Concurrent Validity, and Face Validity
    Geerse, Daphne J.
    Coolen, Bert
    Roerdink, Melvyn
    SENSORS, 2020, 20 (11) : 1 - 12
  • [33] Concurrent validity of human pose tracking in video for measuring gait parameters in older adults: a preliminary analysis with multiple trackers, viewing angles, and walking directions
    Sina Mehdizadeh
    Hoda Nabavi
    Andrea Sabo
    Twinkle Arora
    Andrea Iaboni
    Babak Taati
    Journal of NeuroEngineering and Rehabilitation, 18
  • [34] The Use of Embedded IMU Insoles to Assess Gait Parameters: A Validation and Test-Retest Reliability Study
    Riglet, Louis
    Nicol, Fabien
    Leonard, Audrey
    Eby, Nicolas
    Claquesin, Lauranne
    Orliac, Baptiste
    Ornetti, Paul
    Laroche, Davy
    Gueugnon, Mathieu
    SENSORS, 2023, 23 (19)
  • [35] Use of Pressure-Measuring Insoles to Characterize Gait Parameters in Simulated Reduced-Gravity Conditions
    Ison, Christian
    Neilsen, Connor
    DeBerardinis, Jessica
    Trabia, Mohamed B.
    Dufek, Janet S.
    SENSORS, 2021, 21 (18)
  • [36] Reliability and Concurrent Validity of the Perometer for Measuring Hand Volume in Women With and Without Lymphedema
    Lee, Mi-Joung
    Boland, Robert A.
    Czerniec, Sharon
    Kilbreath, Sharon L.
    LYMPHATIC RESEARCH AND BIOLOGY, 2011, 9 (01) : 13 - 18
  • [37] Development and validity of methods for the estimation of temporal gait parameters from heel-attached inertial sensors in younger and older adults
    Misu, Shogo
    Asai, Tsuyoshi
    Ono, Rei
    Sawa, Ryuichi
    Tsutsumimoto, Kota
    Ando, Hiroshi
    Doi, Takehiko
    GAIT & POSTURE, 2017, 57 : 295 - 298
  • [38] Validity and Reliability of Gait and Postural Control Analysis Using the Tri-axial Accelerometer of the iPod Touch
    Nienke M. Kosse
    Simone Caljouw
    Danique Vervoort
    Nicolas Vuillerme
    Claudine J. C. Lamoth
    Annals of Biomedical Engineering, 2015, 43 : 1935 - 1946
  • [39] Test-retest reliability of temporal and spatial gait characteristics measured with an instrumented walkway system (GAITRite)
    Van Uden C.J.T.
    Besser M.P.
    BMC Musculoskeletal Disorders, 5 (1)
  • [40] Reliability, Concurrent Validity, and Minimal Detectable Change of a Smartphone Application for Measuring Thoracic Kyphosis
    Sahinoglu, Ertan
    Ergin, Gulbin
    Bakirhan, Serkan
    Unver, Bayram
    CLINICAL AND EXPERIMENTAL HEALTH SCIENCES, 2023, 13 (03): : 511 - 516