Concurrent validity and reliability of wireless instrumented insoles measuring postural balance and temporal gait parameters

被引:36
|
作者
Oerbekke, Michiel S. [1 ,2 ]
Stukstette, Mirelle J. [1 ,2 ]
Schutte, Kurt [3 ,4 ]
de Bie, Rob A. [5 ]
Pisters, Martijn F. [1 ,2 ,6 ]
Vanwanseele, Benedicte [3 ,6 ]
机构
[1] Univ Med Ctr Utrecht, Dept Rehabil Nursing Sci & Sport, Brain Ctr Rudolf Magnus, Phys Therapy Res, Utrecht, Netherlands
[2] Julius Hlth Care Centers, Ctr Phys Therapy Res & Innovat Primary Care, Utrecht, Netherlands
[3] Katholieke Univ Leuven, Fac Kinesiol & Rehabil Sci, Dept Kinesiol, Leuven, Belgium
[4] Univ Stellenbosch, Dept Sport Sci, Stellenbosch, South Africa
[5] Maastricht Univ, CAPHRI Sch Publ Hlth & Primary Care, Dept Epidemiol, Maastricht, Netherlands
[6] Fontys Univ Appl Sci, Dept Hlth Innovat & Technol, Eindhoven, Netherlands
关键词
Center of pressure; Spatiotemporal; Gait; Instrumented insoles; HIP OSTEOARTHRITIS; PLANTAR PRESSURE; METAANALYSIS; SYSTEM; KNEE; AGREEMENT; WALKING; FOOT;
D O I
10.1016/j.gaitpost.2016.10.005
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: The OpenGo seems promising to take gait analysis out of laboratory settings due to its capability of long-term measurements and mobility. However, the OpenGo's concurrent validity and reliability need to be assessed to determine if the instrument is suitable for validation in patient samples. Methods: Twenty healthy volunteers participated. Center of pressure data were collected under eyes open and closed conditions with participants performing unilateral stance trials on the gold standard (AMTI OR6-7 force plate) while wearing the OpenGo. Temporal gait data (stance time, gait cycle time, and cadence) were collected at a self-selected comfortable walking speed with participants performing test-retest trials on an instrumented treadmill while wearing the OpenGo. Validity was assessed using Bland-Altman plots. Reliability was assessed with Intraclass Correlation Coefficient (2,1) and smallest detectable changes were calculated. Findings: Negative means of differences were found in all measured parameters, illustrating lower scores for the OpenGo on average. The OpenGo showed negative upper limits of agreement in center of pressure parameters on the mediolateral axis. Temporal reliability ICCs ranged from 0.90-0.93. Smallest detectable changes for both stance times were 0.04 (left) and 0.05 (right) seconds, for gait cycle time 0.08 s, and for cadence 4.5 steps per minute. Interpretation: The OpenGo is valid and reliable for the measurement of temporal gait parameters during walking. Measurements of center of pressure parameters during unilateral stance are not considered valid. The OpenGo seems a promising instrument for clinically screening and monitoring temporal gait parameters in patients, however validation in patient populations is needed. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:116 / 124
页数:9
相关论文
共 50 条
  • [1] Creteil, Evaluation of the Validity and Reliability of Connected Insoles to Measure Gait Parameters in Healthy Adults
    Jacobs, Damien
    Farid, Leila
    Ferre, Sabine
    Herraez, Kilian
    Gracies, Jean-Michel
    Hutin, Emilie
    SENSORS, 2021, 21 (19)
  • [2] Validity Analysis of WalkerViewTM Instrumented Treadmill for Measuring Spatiotemporal and Kinematic Gait Parameters
    Bravi, Marco
    Massaroni, Carlo
    Santacaterina, Fabio
    Di Tocco, Joshua
    Schena, Emiliano
    Sterzi, Silvia
    Bressi, Federica
    Miccinilli, Sandra
    SENSORS, 2021, 21 (14)
  • [3] CONCURRENT VALIDITY AND RELIABILITY OF A LOW-COST GAIT ANALYSIS SYSTEM FOR ASSESSMENT OF SPATIOTEMPORAL GAIT PARAMETERS
    van Bloemendaal, Maijke
    Beelen, Anita
    Kleissen, Rob F. M.
    Geurts, Alexander C. H.
    Nollet, Frans
    Bus, Sicco A.
    JOURNAL OF REHABILITATION MEDICINE, 2019, 51 (06) : 456 - 463
  • [4] Validity and reliability of a portable gait analysis system for measuring spatiotemporal gait characteristics: comparison to an instrumented treadmill
    Donath, Lars
    Faude, Oliver
    Lichtenstein, Eric
    Nueesch, Corina
    Muendermann, Annegret
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2016, 13
  • [5] Validity and Reliability of Spatio-Temporal Gait Parameters in Adolescents
    Cuccia, Antonino Marco
    IRANIAN JOURNAL OF PEDIATRICS, 2013, 23 (05) : 610 - 611
  • [6] Accuracy, concurrent validity, and test-retest reliability of pressure-based insoles for gait measurement in chronic stroke patients
    Neumann, Saskia
    Bauer, Christoph M.
    Nastasi, Luca
    Laderach, Julia
    Thurlimann, Eva
    Schwarz, Anne
    Held, Jeremia P. O.
    Easthope, Chris A.
    FRONTIERS IN DIGITAL HEALTH, 2024, 6
  • [7] Concurrent validity of the Microsoft Kinect for Windows v2 for measuring spatiotemporal gait parameters
    Dolatabadi, Elham
    Taati, Babak
    Mihailidis, Alex
    MEDICAL ENGINEERING & PHYSICS, 2016, 38 (09) : 952 - 958
  • [8] Concurrent validity and intratester reliability of the video-based system for measuring gait poststroke
    Aung, Nilar
    Bovonsunthonchai, Sunee
    Hiengkaew, Vimonwan
    Tretriluxana, Jarugool
    Rojasavastera, Rom Manee
    Pheung-Phrarattanatrai, Anuchai
    PHYSIOTHERAPY RESEARCH INTERNATIONAL, 2020, 25 (01)
  • [9] Concurrent validity of the ZeroWire® footswitch system for the measurement of temporal gait parameters
    Pradeau, C.
    Sturbois-Nachef, N.
    Allart, E.
    GAIT & POSTURE, 2020, 82 : 133 - 137
  • [10] Towards Mobile Gait Analysis: Concurrent Validity and Test-Retest Reliability of an Inertial Measurement System for the Assessment of Spatio-Temporal Gait Parameters
    Kluge, Felix
    Gassner, Heiko
    Hannink, Julius
    Pasluosta, Cristian
    Klucken, Jochen
    Eskofier, Bjoern M.
    SENSORS, 2017, 17 (07):