Design progress on ITER port plug test facility

被引:4
作者
Levesy, B. [1 ]
Beaumont, B. [1 ]
Bruno, L. [2 ]
Cerisier, T. [2 ]
Cordier, J. J. [1 ]
Dammann, A. [1 ]
Giancarli, L. [1 ]
Henderson, M. [1 ]
Romannikov, A. [3 ]
Rumyantsev, Y. [4 ]
Udintsev, V. S. [1 ]
机构
[1] ITER Org, F-13115 St Paul Les Durance, France
[2] ZI Bregaillon, CNIM, F-83507 La Seyne Sur Mer, France
[3] IV Kurchatov Atom Energy Inst, Russian Res Ctr, ITER Agcy, Moscow 123182, Russia
[4] JSC Cryogenmash, Balashikha 143907, Moscow Reg, Russia
关键词
ITER; Port plug; Test facility; Hot cell; Maintenance; COMPONENTS;
D O I
10.1016/j.fusengdes.2012.02.085
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
To achieve the overall ITER machine availability target, the availability of diagnostics and heating port plugs shall be as high as 99.5%. To fulfill these requirements, it is mandatory to test the port plugs at operating temperature before installation on the machine and after refurbishment. The ITER port plug test facility (PFTF) provides the possibility to test upper and equatorial port plugs before installation on the machine. The port plug test facility is composed of several test stands. These test stands are first used in the domestic agencies and on the ITER Organization site to test the port plugs at the end of manufacturing. Two of these stands are installed later in the ITER hot cell facility to test the port plugs after refurbishment. The port plugs to be tested are the Ion Cyclotron (IC) heating and current drive antennas, Electron Cyclotron (EC) heating and current drive launchers, diagnostics and test blanket modules port plugs. Test stands shall be capable to perform environmental and functional tests. The test stands are composed of one vacuum tank (3.3 m in diameter, 5.6 m long) and the associated heating, vacuum and control systems. The vacuum tank shall achieve an ultimate pressure of 1 x 10(-5) Pa at 100 degrees C containing a port plug. The heating system shall provide water at 240 degrees C and 4.4 MPa to heat up the port plugs. Openings are provided on the back of the vacuum tank to insert probes for the functional tests. This paper describes the tests to be performed on the port plugs and the conceptual design of the port plug test facility. The configuration of the standalone test stands and the integration in the hot cell facility are presented. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:1060 / 1064
页数:5
相关论文
共 3 条
[1]   New high power CW test facilities for ITER ICRH components testing [J].
Bernard, J. M. ;
Lombard, G. ;
Argouarch, A. ;
Chaix, J. P. ;
Fejoz, P. ;
Garibaldi, P. ;
Hatchressian, J. C. ;
Lebourg, P. ;
Martinez, A. ;
Mollard, P. ;
Mougeolle, G. ;
Noel, F. ;
Saille, A. ;
Samaille, F. ;
Soler, B. ;
Thouvenin, D. ;
Volpe, D. ;
Vulliez, K. .
FUSION ENGINEERING AND DESIGN, 2011, 86 (6-8) :876-879
[2]   Ten years of maintenance on Tore Supra actively cooled components [J].
Cordier, JJ ;
Chantant, M ;
Chappuis, P ;
Durocher, A .
FUSION ENGINEERING AND DESIGN, 2000, 51-52 :949-954
[3]   PROGRESS IN THE DEVELOPMENT OF THE ITER ECE DIAGNOSTIC [J].
Udintsev, V. S. ;
Vayakis, G. ;
Costley, A. E. ;
Patel, K. M. ;
Pitcher, C. S. ;
Walker, C. I. ;
Walsh, M. J. ;
Benchikhoune, M. ;
Bora, D. ;
Dammann, A. ;
Henderson, M. A. ;
Levesy, B. ;
Tesini, A. ;
Danani, S. ;
Pandya, H. ;
Vasu, P. ;
Austin, M. E. ;
Phillips, P. E. ;
Rowan, W. L. ;
Feder, R. ;
Johnson, D. .
FUSION SCIENCE AND TECHNOLOGY, 2011, 59 (04) :678-683