Liquid chromatography-isotope dilution tandem mass spectrometry method for the measurement of urea in human serum and assignment of reference values to external quality assessment samples

被引:5
|
作者
Yong, Sharon [1 ]
Liu, Hong [1 ]
Wong, Lingkai [1 ]
Teo, Hui Ling [1 ]
Chen, Yizhao [1 ]
Liu, Qinde [1 ]
Teo, Tang Lin [1 ]
Lee, Tong Kooi [1 ]
机构
[1] Chem Metrol Div, Appl Sci Grp, Hlth Sci Author, Singapore, Singapore
关键词
Urea; Human serum; Isotope dilution mass spectrometry; Liquid chromatography-isotope dilution; tandem mass spectrometry; Reference measurement procedure; External quality assessment;
D O I
10.1016/j.ijms.2017.01.013
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Reference measurement procedures are essential for the accurate measurement of urea in human serum. The widely used gas chromatography-isotope dilution mass spectrometry (GC-IDMS) involves tedious derivatization processes. We developed and validated a simple liquid chromatography-isotope dilution tandem mass spectrometry (LC-IDMS/MS) method for the measurement of urea in human serum. In this method, C-13,N-15(2)-urea was spiked into serum samples as the internal standard, and pure urea certified reference material (CRM) was used as the calibration standard to ensure the traceability of the measurements to the International System of Units (SI). The sample cleanup procedure involved a simple protein precipitation step, followed by centrifugation and filtration. The developed LC-IDMS/MS method was found to be accurate and highly reproducible. The coefficient of variation (CV) was generally below 1%. Good accuracy was demonstrated by measuring serum CRM5 from two National Metrology Institutes (NMIs) with relative deviations from the certified values being close to or below 1%, and measurement uncertainties of 2.0%-2.8%. The method was used to assign the reference values of serum urea in ten cycles of an external quality assessment (EQA) program for clinical laboratories over a period of four years. The robust mean of the reported results from clinical laboratories using automated analyzers were close to the assigned values from LC-IDMS/MS method. With good accuracy and precision, as well as simple sample cleanup procedure, the developed LCIDMS/MS method can be used as a reference measurement procedure for the measurement of urea in human serum. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:87 / 93
页数:7
相关论文
共 50 条
  • [41] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of gabapentin in human serum and plasma
    Salzmann, Linda
    Wild, Janik
    Singh, Neeraj
    Schierscher, Tobias
    Liesch, Franziska
    Bauland, Friederike
    Geistanger, Andrea
    Risch, Lorenz
    Geletneky, Christian
    Seger, Christoph
    Taibon, Judith
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (11) : 1955 - 1966
  • [42] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of primidone in human serum and plasma
    Schierscher, Tobias
    Salzmann, Linda
    Singh, Neeraj
    Fischer, Vanessa
    Kobel, Anja
    Bauland, Friederike
    Geistanger, Andrea
    Risch, Lorenz
    Geletneky, Christian
    Seger, Christoph
    Taibon, Judith
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2024, 62 (07) : 1327 - 1338
  • [43] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of aldosterone in human serum and plasma
    Taibon, Judith
    Santner, Tobias
    Singh, Neeraj
    Ibrahim, Sara Cheikh
    Babitzki, Galina
    Koeppl, Daniel
    Gaudl, Alexander
    Geistanger, Andrea
    Ceglarek, Uta
    Rauh, Manfred
    Geletneky, Christian
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (11) : 1902 - 1916
  • [44] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of methotrexate in human serum and plasma
    Engel, Anett
    Ruhe, Lena
    Singh, Neeraj
    Wright, Jo Anne
    Liesch, Franziska
    Bauland, Friederike
    Ostermann, Annika I. I.
    Sumalowitsch, Tamara
    Schweinsberg, Vincent J. T.
    Geistanger, Andrea
    Hegel, Johannes Kolja
    Geletneky, Christian
    Taibon, Judith
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (11) : 1917 - 1929
  • [45] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of lamotrigine in human serum and plasma
    Salzmann, Linda
    Spescha, Tino
    Singh, Neeraj
    Schierscher, Tobias
    Bachmann, Martina
    Bauland, Friederike
    Geistanger, Andrea
    Risch, Lorenz
    Geletneky, Christian
    Seger, Christoph
    Taibon, Judith
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (11) : 1930 - 1941
  • [46] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of phenobarbital in human serum and plasma
    Schierscher, Tobias
    Salzmann, Linda
    Singh, Neeraj
    Bachmann, Martina
    Kobel, Anja
    Wild, Janik
    Bauland, Friederike
    Geistanger, Andrea
    Risch, Lorenz
    Geletneky, Christian
    Seger, Christoph
    Taibon, Judith
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2024, 62 (07) : 1314 - 1326
  • [47] Development and Validation of a Novel Isotope Dilution-Ultraperformance Liquid Chromatography- Tandem Mass Spectrometry Method for Serum C-Peptide
    Cho, Sung-Eun
    Han, Jungsun
    You, Juyoung
    Lee, Jun Hyung
    Yi, Ahram
    Lee, Sang Gon
    Lee, Eun Hee
    ANNALS OF LABORATORY MEDICINE, 2025, 45 (01) : 62 - 69
  • [48] Establishment of an absolute quantitative method for measurement of urinary cystatin C by stable isotope dilution ultra high performance liquid chromatography tandem mass spectrometry
    Ji, Huoyan
    Shen, Lei
    Shi, Xiuying
    Su, Jianyou
    Tang, Zijie
    Wang, Huimin
    Ju, Shaoqin
    Wang, Jianxin
    ANALYTICAL METHODS, 2018, 10 (43) : 5236 - 5241
  • [49] Measurement of human serum unconjugated estriol without derivatization using liquid chromatography-tandem mass spectrometry candidate reference method and compared with two immunoassays
    Xianzhang Huang
    Qiaoxuan Zhang
    Songbai Zheng
    Jianbing Wang
    Liqiao Han
    Haibiao Lin
    Peifeng Ke
    Junhua Zhuang
    Zhimin (Tim) Cao
    Analytical and Bioanalytical Chemistry, 2018, 410 : 6257 - 6267
  • [50] Measurement of human serum unconjugated estriol without derivatization using liquid chromatography-tandem mass spectrometry candidate reference method and compared with two immunoassays
    Huang, Xianzhang
    Zhang, Qiaoxuan
    Zheng, Songbai
    Wang, Jianbing
    Han, Liqiao
    Lin, Haibiao
    Ke, Peifeng
    Zhuang, Junhua
    Cao, Zhimin
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (24) : 6257 - 6267