Scatter Correction with Combined Single-Scatter Simulation and Monte Carlo Simulation for 3D PET

被引:0
作者
Ye, Jinghan [1 ]
Song, Xiyun [1 ]
Hu, Zhiqiang [2 ]
机构
[1] Philips Healthcare, San Jose, CA 95134 USA
[2] Philips Healthcare, Cleveland, OH USA
来源
2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) | 2014年
关键词
PET; scatter correction; Monte Carlo; single-scatter simulation;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In positron emission tomography (PET) imaging, scattered gamma photons typically account for more than 30% of total detected coincidence counts. Single scatter simulation (SSS) method is widely used for estimating scatter contribution in PET image reconstruction. Monte Carlo (MC) techniques are more accurate but computationally expensive. When using SSS, the modeled scatter contribution is typically scaled to match the measured data. Typically tail fitting is used for this scaling. However, when the available tail part is either too small or too noisy, the tail fitting technique may lead to artifacts in the reconstructed images. In this study, a hybrid method that combines SSS and MC is presented. The method uses SSS to approximate the shape of scatter contribution, and scales the SSS result by a scaling factor derived from a low-count MC simulation. Effectiveness of the method is evaluated with phantom and patient studies. Images reconstructed using SSS with tail-fitting scaling (SSS-TFS) and SSS with Monte Carlo scaling (SSS-MCS) are compared. Results show that SSS-MCS significantly reduces or eliminates the artifacts that present in SSS-TFS images. For smaller objects, both SSS-MCS and SSS-TFS produce artifact-free images. The MC simulation takes less than a second on a computer with 8 CPU cores to achieve less than 1% of scatter scaling factor variation. A hybrid scatter correction method that combines SSS and Monte Carlo simulation is developed for PET reconstruction. The method demonstrates a significant improvement in scatter correction accuracy. The added computational cost is negligible.
引用
收藏
页数:3
相关论文
共 50 条
  • [41] Characterization of scatter factors in thyroid studies using a pinhole collimator by Monte Carlo Simulation
    Rodriguez, S.
    Lopez, A.
    Diaz, A.
    Palau, A.
    Martin, J. M.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 181 - 186
  • [42] Use of Monte Carlo simulations for the scatter events analysis of PET scanners
    Gao Fei
    Yamada, Ryoko
    Watanabe, Mitsuo
    Liu Hua-Feng
    ACTA PHYSICA SINICA, 2009, 58 (05) : 3584 - 3591
  • [43] 3D parallel Monte Carlo simulation of GaAs MESFETs
    Pennathur, S
    Sandalci, CK
    Koc, CK
    Goodnick, SM
    VLSI DESIGN, 1998, 6 (1-4) : 273 - 276
  • [44] Do Scatter and Random Corrections Affect the Errors in Kinetic Parameters in Dynamic PET? - A Monte Carlo Study
    Haggstrom, Ida
    Schmidtlein, C. Ross
    Karlsson, Mikael
    Larsson, Anne
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [45] Photon Propagation Correction in 3D Photoacoustic Image Reconstruction using Monte Carlo Simulation
    Cheong, Yaw Jye
    Stantz, Keith M.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2010, 2010, 7564
  • [46] Scatter correction based on adaptive photon path-based Monte Carlo simulation method in Multi-GPU platform
    Zhang, Yangmei
    Chen, Yusi
    Zhong, Anni
    Jia, Xun
    Wu, Shuyu
    Qi, Hongliang
    Zhou, Linghong
    Xu, Yuan
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2020, 194
  • [47] Implementation of GPU accelerated SPECT reconstruction with Monte Carlo-based scatter correction
    Tobias Bexelius
    Antti Sohlberg
    Annals of Nuclear Medicine, 2018, 32 : 337 - 347
  • [48] Implementation of GPU accelerated SPECT reconstruction with Monte Carlo-based scatter correction
    Bexelius, Tobias
    Sohlberg, Antti
    ANNALS OF NUCLEAR MEDICINE, 2018, 32 (05) : 337 - 347
  • [49] Comparative evaluation of scatter correction techniques in 3D positron emission tomography
    Zaidi, H
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2000, 27 (12) : 1813 - 1826
  • [50] Simulation Study of Scatter Correction in Photon Counting CT
    Kojima, Shinichi
    Yokoi, Kazuma
    Takahashi, Isao
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573