Morphological variation of nonreentrant idiopathic ventricular tachycardia originating from the right ventricular outflow tract and effect of radiofrequency lesion

被引:9
作者
Chinushi, M
Aizawa, Y
Takahashi, K
Kouji, O
Kitazawa, H
Washizuka, T
Abe, A
Shibata, A
机构
[1] First Dept. of Internal Medicine, Niigata University, School of Medicine, Niigata
[2] First Dept. of Internal Medicine, Niigata University, School of Medicine, Niigata 951
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1997年 / 20卷 / 02期
关键词
QRS variation; idiopathic right ventricular tachycardia; radiofrequency ablation;
D O I
10.1111/j.1540-8159.1997.tb06177.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
RF catheter ablation was performed in 16 patients with nonreentrant idiopathic VT originating from the RVOT. All documented VT was monomorphic, but subtle morphological variation in the VT-QRS complex was observed in 10 (63%) of 16 patients. Through endocardial mapping, VT Origin was determined within a narrow site (< 0.5 X 0.5 cm) in 4 of the 10 patients with the morphological variation. In the other 6 of 10 patients, the origin extended to an area of > 0.5 X 0.5 cm. In VT with morphological variation, the local electrogram at the site of VT origin also showed variation in morphology and activation sequence. For VT of narrow origin, RF application to the site eliminated the TIT. However, in VT from a wide arrhythmogenic area, RF current had to be delivered to 3-7 distinct sites to cover the possible origin, and specific QRS configuration of VT and/or PVC was ablated at each of the earliest activation site. All but one VT were successfully ablated by RF current. Subtle morphological variation was frequent in this type of VT, and about half were associated with a wide arrhythmogenic area. Precise mapping and analysis of the efficacy of each RF application might be helpful to better understand the relationship between subtle changes of VT-QRS morphology and their origins.
引用
收藏
页码:325 / 336
页数:12
相关论文
共 21 条
  • [1] CATHETER ABLATION OF VENTRICULAR-TACHYCARDIA WITH RADIOFREQUENCY CURRENTS, WITH SPECIAL REFERENCE TO THE TERMINATION AND MINOR MORPHOLOGIC CHANGE OF REINDUCED VENTRICULAR-TACHYCARDIA
    AIZAWA, Y
    CHINUSHI, M
    NAITOH, N
    KITAZAWA, H
    WASHIZUKA, T
    UCHIYAMA, H
    SHIBATA, A
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (08) : 574 - 579
  • [2] INCIDENCE AND MECHANISM OF INTERRUPTION OF REENTRANT VENTRICULAR-TACHYCARDIA WITH RAPID VENTRICULAR PACING
    AIZAWA, Y
    NIWANO, S
    CHINUSHI, M
    TAMURA, M
    KUSANO, Y
    MIYAJIMA, T
    KITAZAWA, H
    SHIBATA, A
    [J]. CIRCULATION, 1992, 85 (02) : 589 - 595
  • [3] FREQUENCY OF PRESUMED REENTRY WITH AN EXCITABLE GAP IN SUSTAINED VENTRICULAR-TACHYCARDIA UNASSOCIATED WITH CORONARY-ARTERY DISEASE
    AIZAWA, Y
    NAITOH, N
    KITAZAWA, H
    KUSANO, Y
    UCHIYAMA, H
    WASHIZUKA, T
    SHIBATA, A
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (12) : 916 - 921
  • [4] ENTRAINMENT OF VENTRICULAR-TACHYCARDIA IN ARRHYTHMOGENIC RIGHT VENTRICULAR-TACHYCARDIA
    AIZAWA, Y
    FUNAZAKI, T
    TAKAHASHI, M
    NAITOH, N
    MIYAJIMA, T
    KUSANO, Y
    SHIBATA, A
    MISAKI, T
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (11): : 1606 - 1613
  • [5] CATHETER ABLATION WITH RADIOFREQUENCY CURRENT OF VENTRICULAR-TACHYCARDIA ORIGINATING FROM THE RIGHT VENTRICLE
    AIZAWA, Y
    CHINUSHI, M
    NAITOH, N
    KUSANO, Y
    KITAZAWA, H
    TAKAHASHI, K
    UCHIYAMA, H
    SHIBATA, A
    [J]. AMERICAN HEART JOURNAL, 1993, 125 (05) : 1269 - 1275
  • [6] RADIOFREQUENCY CURRENT CATHETER ABLATION FOR VENTRICULAR-TACHYCARDIA
    CHINUSHI, M
    AIZAWA, Y
    KUSANO, Y
    WASHIZUKA, T
    MIYAJIMA, T
    NAITHO, N
    TAKAHASHI, K
    SHIBATA, A
    [J]. JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1994, 58 (05): : 315 - 325
  • [7] FREQUENCY AND OUTPUT-DEPENDENT CHANGE IN CONDUCTION OVER SLOW PATHWAYS IN A PATIENT WITH SUSTAINED VENTRICULAR-TACHYCARDIA UNRELATED TO CORONARY-ARTERY DISEASE
    CHINUSHI, M
    AIZAWA, Y
    FUNAZAKI, T
    TAMURA, M
    SHIBATA, A
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (05): : 756 - 761
  • [8] CHINUSHI M, 1993, JPN HEART J, V34, P227
  • [9] CHINUSHI M, 1995, IN PRESS BR HEART J
  • [10] RADIOFREQUENCY CATHETER ABLATION FOR TREATMENT OF BUNDLE-BRANCH REENTRANT VENTRICULAR-TACHYCARDIA - RESULTS AND LONG-TERM FOLLOW-UP
    COHEN, TJ
    CHIEN, WW
    LURIE, KG
    YOUNG, C
    GOLDBERG, HR
    WANG, YS
    LANGBERG, JJ
    LESH, MD
    LEE, MA
    GRIFFIN, JC
    SCHEINMAN, MM
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (07) : 1767 - 1773