Impact of cement-augmented condylar screws in locking plate osteosynthesis for distal femoral fractures - A biomechanical analysis

被引:14
|
作者
Bliemel, Christopher [1 ]
Oberkircher, Ludwig [1 ]
Bockmann, Benjamin [1 ]
Petzold, Eric [1 ]
Aigner, Rene [1 ]
Heyse, Thomas Jan [1 ]
Ruchholtz, Steffen [1 ]
Buecking, Benjamin [1 ]
机构
[1] Univ Hosp Giessen & Marburg, Ctr Orthopaed & Trauma Surg, Baldingerstr, D-35043 Marburg, Germany
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2016年 / 47卷 / 12期
关键词
Distal femoral fracture; Polyaxial angular stable plate osteosynthesis; Cement augmentation; Osteoporosis; Biomechanical analysis; INVASIVE STABILIZATION SYSTEM; FEMUR FRACTURES; IMPLANT AUGMENTATION; INTERNAL-FIXATION; BLADE PLATE; BONE; TRIAL; NAIL;
D O I
10.1016/j.injury.2016.10.013
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Compromised bone quality and the need for early mobilization continue to lead to implant failure in elderly patients with distal femoral fractures. The cement augmentation of screws might facilitate improving implant anchorage. The aim of this study was to analyse the impact of cement augmentation of the condylar screws on implant fixation in a human cadaveric bone model. Material and methods: Ten pairs of osteoporotic femora (mean age: 90 years, range: 84-99 years) were used. A 2-cm gap osteotomy was created in the metaphyseal region to simulate an unstable AO/OTA 33-A3 fracture. All specimens were treated with a polyaxial locking plate. Specimens randomly assigned to the augmented group received an additional cement augmentation of the condylar screws using bone cement. A servohydraulic testing machine was used to perform incremental cyclic axial loading using a load-to-failure mode. Results: All specimens survived at least 800 N of axial compressive force. The mean compressive forces leading to failure were 1620 N (95% CI: 1382-1858 N) in the non-augmented group and 2420 N (95% CI: 2054-2786 N) in the group with cement-augmented condylar screws (p = 0.005). Deformation with cutting out of the condylar screws and condylar fracture were the most common reasons for failure in both groups. Whereas axial stiffness was comparable between both osteosyntheses (p = 0.508), significant differences were observed for the plastic deformation of the constructs (p = 0.014). Conclusion: The results of the present study showed that the cement augmentation of the condylar screws might be a promising technique for the fixation of distal femoral fractures in elderly patients with osteoporotic bones. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2688 / 2693
页数:6
相关论文
共 50 条
  • [31] Combination of anatomical locking plate and retrograde intramedullary nail in distal femoral fractures: comparison of mechanical stability
    Basci, Onur
    Karakasli, Ahmet
    Kumtepe, Erdem
    Guran, Orta
    Havitcioglu, Hasan
    EKLEM HASTALIKLARI VE CERRAHISI-JOINT DISEASES AND RELATED SURGERY, 2015, 26 (01): : 21 - 26
  • [32] Cement-augmented sacroiliac screw fixation with cannulated versus perforated screws - A biomechanical study in an osteoporotic hemipelvis model
    Hack, J.
    Krueger, A.
    Masaeli, A.
    Aigner, R.
    Ruchholtz, S.
    Oberkircher, L.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2018, 49 (08): : 1520 - 1525
  • [33] Severity of Complications after Locking Plate Osteosynthesis in Distal Femur Fractures
    Gurung, Roshan
    Terrill, Alexander
    White, Gentry
    Windolf, Markus
    Hofmann-Fliri, Ladina
    Dlaska, Constantin
    Schuetz, Michael
    Epari, Devakara R.
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (05)
  • [34] Plate-on-plate technique for treating peri-implant fractures of distal femoral locking plate: a retrospective study of 11 patients
    Ma, Ching-Hou
    Chiu, Yen-Chun
    Wu, Chin-Hsien
    Tsai, Kun-Ling
    Wen, Tsung-Kai
    Jou, I-Ming
    Tu, Yuan-Kun
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2019, 139 (09) : 1245 - 1251
  • [35] Biomechanical Evaluation of Plate Osteosynthesis of Distal Fibula Fractures with Biodegradable Devices
    Klos, Kajetan
    Sauer, Stefanie
    Hoffmeier, Konrad
    Gras, Florian
    Froeber, Rosemarie
    Hofmann, Gunther O.
    Mueckley, Thomas
    FOOT & ANKLE INTERNATIONAL, 2009, 30 (03) : 243 - 251
  • [36] DISTAL FEMORAL LOCKING COMPRESSION PLATE FIXATION IN DISTAL FEMORAL FRACTURES: ONE YEAR HOSPITAL BASED STUDY
    Patil, Kiran
    Patil, Mahantesh
    Khadabadi, Nikhil
    Patel, Chintan
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2014, 3 (28): : 7911 - 7919
  • [37] Percutaneous Cement-Augmented Screws Short Fixation for the Treatment of Severe Osteoporotic Vertebra Burst Fractures
    Fiore, Giorgio
    Tariciotti, Leonardo
    Borsa, Stefano
    Nicoli, Daniele
    Schisano, Luigi
    Bertani, Giulio Andrea
    Locatelli, Marco
    Pluderi, Mauro
    WORLD NEUROSURGERY, 2022, 163 : E522 - E531
  • [38] Locking plate fixation versus antegrade intramedullary nailing for the treatment of extra-articular distal femoral fractures
    Ocalan, E.
    Ustun, C. C.
    Aktuglu, K.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 : 55 - 62
  • [39] Posterior instrumentation for osteoporotic fractures in the thoracic or lumbar spine: Cement-augmented pedicle screws vs hybrid constructs
    Chou, Po-Hsin
    Lin, Hsi-Hsien
    Yao, Yu-Cheng
    Wang, Shih-Tien
    Chang, Ming-Chau
    Liu, Chien-Lin
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2023, 86 (04) : 431 - 439
  • [40] Malalignment after minimally invasive plate osteosynthesis in distal femoral fractures
    Kim, Joon-Woo
    Oh, Chang-Wug
    Oh, Jong-Keon
    Park, Il-Hyung
    Kyung, Hee-Soo
    Park, Kyeong-Hyeon
    Yoon, Seong-Dae
    Kim, Seong-Min
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 (03): : 751 - 757