Minimizing Contrast Medium Doses to Diagnose Pulmonary Embolism with 80-kVp Multidetector Computed Tomography in Azotemic Patients

被引:53
作者
Holmquist, F. [1 ]
Hansson, K. [2 ]
Pasquariello, F. [2 ]
Bjork, J. [3 ]
Nyman, U. [4 ]
机构
[1] Lund Univ, Malmo Univ Hosp, Dept Diagnost Radiol, Malmo, Sweden
[2] Lund Univ, Dept Internal Med, Trelleborg, Sweden
[3] Lund Univ, Univ Hosp, Competence Ctr Clin Res, Lund, Sweden
[4] Lund Univ, Dept Radiol, SE-23185 Trelleborg, Sweden
关键词
Computed tomography; contrast material; contrast medium-induced nephropathy; nephrotoxicity; pulmonary embolism; PERCUTANEOUS CORONARY INTERVENTION; CREATININE CLEARANCE RATIO; COMBINED CT VENOGRAPHY; CHRONIC KIDNEY-DISEASE; INDUCED NEPHROPATHY; IMAGE QUALITY; ABDOMINAL CT; CARDIAC-OUTPUT; BODY-WEIGHT; RISK-FACTOR;
D O I
10.1080/02841850802657269
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: In diagnosing acute pulmonary embolism (PE) in azotemic patients, scintigraphy and magnetic resonance imaging are frequently inconclusive or not available in many hospitals. Computed tomography is readily available, but relatively high doses (30-50 g I) of potentially nephrotoxic iodine contrast media (CM) are used. Purpose: To report on the diagnostic quality and possible contrast-induced nephropathy (CIN) after substantially reduced CM doses to diagnose PE in azotemic patients using 80-peak kilovoltage (kVp) 16-row multidetector computed tomography (MDCT) combined with CM doses tailored to body weight, fixed injection duration adapted to scan time, automatic bolus tracking, and saline chaser. Material and Methods: Patients with estimated glomerular filtration rate (eGFR) 50 ml/min were scheduled to undergo 80-kVp MDCT using 200 mg I/kg, and those with eGFR 50 ml/min, 120-kVp MDCT with 320 mg I/kg. Both protocols used an 80-kg maximum dose weight and a fixed 15-s injection time. Pulmonary artery density and contrast-to-noise ratio were measured assuming 70 Hounsfield units (HU) for a fresh clot. CIN was defined as a plasma creatinine rise 44.2 mol/l from baseline. Results: 89/148 patients (63/68 females) underwent 80-/120-kVp protocols, respectively, with 95% of the examinations being subjectively excellent or adequate. Mean values in the 80-/120-kVp cohorts regarding age were 82/65 years, body weight 66/78 kg, effective mAs 277/117, CM dose 13/23 g I, pulmonary artery density 359/345 HU, image noise (1 standard deviation) 24/21 HU, contrast-to-noise ratio 13/13, and dose-length product 173/258 mGycm. Only 1/65 and 2/119 patients in the 80- and 120-kVp cohorts, respectively, with negative CT and no anticoagulation suffered non-fatal thromboembolism during 3-month follow-up. No patient developed CIN. Conclusion: 80-kVp 16-row MDCT with optimization of injection parameters may be performed with preserved diagnostic quality, using markedly reduced CM doses compared with common routine practice, which should be to the benefit of patients at risk of CIN.
引用
收藏
页码:181 / 193
页数:13
相关论文
共 45 条
[1]   MDCT of the coronary arteries: Feasibility of low-dose CT with ECG-pulsed tube current modulation to reduce radiation dose [J].
Abada, Hicham T. ;
Larchez, Christophe ;
Daoud, Beatrice ;
Sigal-Cinqualbre, Anne ;
Paul, Jean-Francois .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (06) :S387-S390
[2]  
[Anonymous], 2002, STAG HEART FAIL NYHA
[3]   Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight [J].
Awai, K ;
Hiraishi, K ;
Hori, S .
RADIOLOGY, 2004, 230 (01) :142-150
[4]   Scan and contrast administration principles of MDCT [J].
Bae, KT ;
Heiken, JP .
EUROPEAN RADIOLOGY, 2005, 15 :E46-E59
[5]   CT depiction of pulmonary emboli: Display window settings [J].
Bae, KT ;
Mody, GN ;
Balfe, DM ;
Bhalla, S ;
Gierada, DS ;
Gutierrez, FR ;
Menias, CO ;
Woodard, PK ;
Goo, IM ;
Hildebolt, CF .
RADIOLOGY, 2005, 236 (02) :677-684
[6]   Aortic and hepatic contrast medium enhancement at CT part II. Effect of reduced cardiac output in a porcine model [J].
Bae, KT ;
Heiken, JP ;
Brink, JA .
RADIOLOGY, 1998, 207 (03) :657-662
[7]   Effect of patient weight and scanning duration on contrast enhancement during pulmonary multidetector CT angiography [J].
Bae, Kyongtae T. ;
Tao, Cheng ;
Gurel, Safiye ;
Hong, Cheng ;
Zhu, Fang ;
Gebke, Todd A. ;
Milite, Margherita ;
Hildebolt, Charles F. .
RADIOLOGY, 2007, 242 (02) :582-589
[8]   Contrast-induced nephropathy in patients with chronic kidney disease undergoing computed tomography - A double-blind comparison of iodixanol and iopamidol [J].
Barrett, Brendan J. ;
Katzberg, Richard W. ;
Thomsen, Henrik S. ;
Chen, Nan ;
Sahani, Dushyant ;
Soulez, Gilles ;
Heiken, Jay P. ;
Lepanto, Luigi ;
Ni, Zhou-Hui ;
Nelson, Rendon .
INVESTIGATIVE RADIOLOGY, 2006, 41 (11) :815-821
[9]   Use of iso-osmolar nonionic dimeric contrast media in multidetector row computed tomography angiography for patients with renal impairment [J].
Becker, CR ;
Reiser, MF .
INVESTIGATIVE RADIOLOGY, 2005, 40 (10) :672-675
[10]   Dose reduction in pediatric CT: A rational approach [J].
Boone, JM ;
Geraghty, EM ;
Seibert, JA ;
Wootton-Gorges, SL .
RADIOLOGY, 2003, 228 (02) :352-360