Effect of Refractive Correction Error on Retinal Nerve Fiber Layer Thickness: A Spectralis Optical Coherence Tomography Study

被引:2
作者
Ma, Xiaoli [1 ]
Chen, Yutong [1 ]
Liu, Xianjie [1 ]
Ning, Hong [1 ]
机构
[1] China Med Univ, Hosp 1, Dept Ophthalmol, Shenyang, Liaoning, Peoples R China
来源
MEDICAL SCIENCE MONITOR | 2016年 / 22卷
基金
中国国家自然科学基金;
关键词
Glaucoma; Refractive Errors; Retina; Tomography; Optical Coherence; OPEN-ANGLE GLAUCOMA; VISUAL-FIELDS; GAZE TRACKING; IMAGE QUALITY; DOMAIN OCT; CIRRUS HD; ARTIFACTS; CATARACT; DEFECTS; EYES;
D O I
10.12659/MSM.898564
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: Identifying and assessing retinal nerve fiber layer defects are important for diagnosing and managing glaucoma. We aimed to investigate the effect of refractive correction error on retinal nerve fiber layer (RNFL) thickness measured with Spectralis spectral-domain optical coherence tomography (SD-OCT). Material/Methods: We included 68 participants: 32 healthy (normal) and 36 glaucoma patients. RNFL thickness was measured using Spectralis SD-OCT circular scan. Measurements were made with a refractive correction of the spherical equivalent (SE), the SE+2.00D and the SE-2.00D. Results: Average RNFL thickness was significantly higher in the normal group (105.88 +/- 10.47 mu m) than in the glaucoma group (67.67 +/- 17.27 mu m, P<0.001). In the normal group, +2.00D of refractive correction error significantly affected measurements of average (P<0.001) and inferior quadrant (P=0.037) RNFL thickness. In the glaucoma group, +2.00D of refractive correction error significantly increased average (P<0.001) and individual quadrant (superior: P=0.016; temporal: P=0.004; inferior: P=0.008; nasal: P=0.003) RNFL measurements compared with those made with the proper refractive correction. However, -2.00D of refractive correction error did not significantly affect RNFL thickness measurements in either group. Conclusions: Positive defocus error significantly affects RNFL thickness measurements made by the Spectralis SD-OCT. Negative defocus error did not affect RNFL measurement examined. Careful correction of refractive error is necessary to obtain accurate baseline and follow-up RNFL thickness measurements in healthy and glaucomatous eyes.
引用
收藏
页码:5181 / 5189
页数:9
相关论文
共 45 条
  • [1] [Anonymous], 2014, TERM GUID GLAUC
  • [2] Artifacts in Spectral-Domain Optical Coherence Tomography Measurements in Glaucoma
    Asrani, Sanjay
    Essaid, Luma
    Alder, Brian D.
    Santiago-Turla, Cecilia
    [J]. JAMA OPHTHALMOLOGY, 2014, 132 (04) : 396 - 402
  • [3] Effect of image quality on tissue thickness measurements obtained with spectral domain-optical coherence tomography
    Balasubramanian, Madhusudhanan
    Bowd, Christopher
    Vizzeri, Gianmarco
    Weinreb, Robert N.
    Zangwill, Linda M.
    [J]. OPTICS EXPRESS, 2009, 17 (05): : 4019 - 4036
  • [4] Influence of cataract surgery on repeatability and measurements of spectral domain optical coherence tomography
    Bambo, Maria P.
    Garcia-Martin, Elena
    Otin, Sofia
    Sancho, Eva
    Fuertes, Isabel
    Herrero, Raquel
    Satue, Maria
    Pablo, Luis
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2014, 98 (01) : 52 - 58
  • [5] Evaluation of the Retinal Nerve Fiber Layer Thickness, the Mean Deviation, and the Visual Field Index in Progressive Glaucoma
    Banegas, Sebastian A.
    Anton, Alfonso
    Morilla, Antonio
    Bogado, Marco
    Ayala, Eleonora M.
    Fernandez-Guardiola, Agustin
    Moreno-Montanes, Javier
    [J]. JOURNAL OF GLAUCOMA, 2016, 25 (03) : E229 - E235
  • [6] Retinal Nerve Fiber Layer Thickness in Normals Measured by Spectral Domain OCT
    Bendschneider, Delia
    Tornow, Ralf P.
    Horn, Folkert K.
    Laemmer, Robert
    Roessler, Christopher W.
    Juenemann, Anselm G.
    Kruse, Friedrich E.
    Mardin, Christian Y.
    [J]. JOURNAL OF GLAUCOMA, 2010, 19 (07) : 475 - 482
  • [7] Error in refractive correction and its impact on scanning laser polarimetry
    Chen, Enping
    Parmer, Eva
    Vennstrom, Yvonne
    [J]. JOURNAL OF GLAUCOMA, 2007, 16 (02) : 196 - 200
  • [8] Topographic Differences in the Age-related Changes in the Retinal Nerve Fiber Layer of Normal Eyes Measured by Stratus Optical Coherence Tomography
    Feuer, William J.
    Budenz, Donald L.
    Anderson, Douglas R.
    Cantor, Louis
    Greenfield, David S.
    Savell, Jonathan
    Schuman, Joel S.
    Varma, Rohit
    [J]. JOURNAL OF GLAUCOMA, 2011, 20 (03) : 133 - 138
  • [9] Thickness of the peripapillary retina in healthy subjects with different degrees of ametropia
    Garcia-Valenzuela, E
    Mori, M
    Edward, DP
    Shahidi, M
    [J]. OPHTHALMOLOGY, 2000, 107 (07) : 1321 - 1327
  • [10] ARTIFACTS IN AUTOMATIC RETINAL SEGMENTATION USING DIFFERENT OPTICAL COHERENCE TOMOGRAPHY INSTRUMENTS
    Giani, Andrea
    Cigada, Mario
    Esmaili, Daniel D.
    Salvetti, Paola
    Luccarelli, Saverio
    Marziani, Ermengarda
    Luiselli, Cristiano
    Sabella, Pierfilippo
    Cereda, Matteo
    Eandi, Chiara
    Staurenghi, Giovanni
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2010, 30 (04): : 607 - 616