Construction of an amperometric bilirubin biosensor based on covalent immobilization of bilirubin oxidase onto zirconia coated silica nanoparticles/chitosan hybrid film

被引:76
|
作者
Batra, Bhawna [1 ]
Lata, Suman [1 ]
Sunny [2 ]
Rana, J. S. [2 ]
Pundir, Chandra Shekhar [1 ]
机构
[1] Maharshi Dayanand Univ, Dept Biochem, Rohtak 124001, Haryana, India
[2] DCR Univ Sci & Technol, Dept Biotechnol, Murthal 131039, Sonepat, India
来源
关键词
Bilirubin; Bilirubin oxidase; Bilirubin biosensor; Zirconia coated silica nanoparticles; Chitosan; Serum; ENZYME ELECTRODE; SERUM;
D O I
10.1016/j.bios.2012.12.034
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A method is described for the construction of a highly sensitive electrochemical biosensor for the detection of bilirubin. The sensor is based on covalent immobilization of bilirubin oxidase (BOx) onto zirconia coated silica nanoparticles (SiO2@ZrONPs)/chitosan (CHIT) composite electrodeposited onto Au electrode. The enzyme electrode was characterized by scanning electron microscopy (SEM), Fourier transform infra-red spectroscopy (FTIR), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The biosensor showed optimum response within 2 s at pH 8.5 (0.1 M Tris-HCl) and 35 degrees C, when operated at 20 mV s(-1). The biosensor exhibited excellent sensitivity (detection limit as 0.1 nM), fast response time and wider linear range (from 0.02 to 250 mu M). Analytical recovery of added bilirubin was 95.56-97.0%. Within batch and between batch coefficients of variation were 3.2% and 3.35% respectively. The enzyme electrode was used 150 times over a period of 120 days, when stored at 4 degrees C. The biosensor measured bilirubin levels in sera of apparently healthy and persons suffering from jaundice, which correlated well with a standard colorimetric method (r=0.99). (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:64 / 69
页数:6
相关论文
共 50 条
  • [1] Construction of an amperometric bilirubin biosensor based on covalent immobilization of bilirubin oxidase onto zirconia coated silica nanoparticles/chitosan hybrid film
    Batra, Bhawna
    Lata, Suman
    Sunny
    Rana, J.S.
    Pundir, Chandra Shekhar
    Biosensors and Bioelectronics, 2013, 44 (01) : 64 - 69
  • [2] Construction of an amperometric glucose biosensor based on the immobilization of glucose oxidase onto electrodeposited Pt nanoparticles-chitosan composite film
    Li, Jingjing
    Yuan, Ruo
    Chai, Yaqin
    Che, Xin
    Li, Wenjuan
    BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2012, 35 (07) : 1089 - 1095
  • [3] Construction of an amperometric glucose biosensor based on the immobilization of glucose oxidase onto electrodeposited Pt nanoparticles-chitosan composite film
    Jingjing Li
    Ruo Yuan
    Yaqin Chai
    Xin Che
    Wenjuan Li
    Bioprocess and Biosystems Engineering, 2012, 35 : 1089 - 1095
  • [4] An amperometric cholesterol biosensor based on immobilization of cholesterol oxidase onto titanium dioxide nanoparticles
    Batra B.
    Narwal V.
    Sumit
    Ahlawat J.
    Sharma M.
    Sensors International, 2021, 2
  • [5] An amperometric glutamate biosensor based on immobilization of glutamate oxidase onto carboxylated multiwalled carbon nanotubes/gold nanoparticles/chitosan composite film modified Au electrode
    Batra, Bhawna
    Pundir, C. S.
    BIOSENSORS & BIOELECTRONICS, 2013, 47 : 496 - 501
  • [6] Amperometric Biosensor Based on Immobilization of Oxalate Oxidase in a Mucin/Chitosan Matrix
    Benavidez, Tomas E.
    Capra, Raul H.
    Alvarez, Cecilia I.
    Baruzzi, Ana M.
    ELECTROANALYSIS, 2009, 21 (07) : 837 - 843
  • [7] Silver Nanoparticles as a Glucose Oxidase Immobilization Matrix for Amperometric Glucose Biosensor Construction
    Hsu, Fu-Yin
    Yu, Ding-Syuan
    Chang, Jung-Che
    Chuang, Chia-Lin
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2011, 58 (06) : 756 - 760
  • [8] Glucose biosensor based on immobilization of glucose oxidase in platinum nanoparticles/graphene/chitosan nanocomposite film
    Wu, Hong
    Wang, Jun
    Kang, Xinhuang
    Wang, Chongmin
    Wang, Donghai
    Liu, Jun
    Aksay, Ilhan A.
    Lin, Yuehe
    TALANTA, 2009, 80 (01) : 403 - 406
  • [9] Construction and application of an amperometric uric acid biosensor based on covalent immobilization of uricase on iron oxide nanoparticles/chitosan-g-polyaniline composite film electrodeposited on Pt electrode
    Devi, Rooma
    Pundir, C. S.
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 193 : 608 - 615
  • [10] Amperometric hydrogen peroxide biosensor with silica sol-gel/chitosan film as immobilization matrix
    Miao, Y
    Tan, SN
    ANALYTICA CHIMICA ACTA, 2001, 437 (01) : 87 - 93