Adensity assignment method for dose monitoring in head-and-neck radiotherapy

被引:0
|
作者
Barateau, A. [1 ]
Perichon, N. [1 ]
Castelli, J. [1 ]
Schick, U. [2 ]
Henry, O. [1 ]
Chajon, E. [1 ]
Simon, A. [1 ]
Lafond, C. [1 ]
De Crevoisier, R. [1 ]
机构
[1] Univ Rennes, INSERM, CLCC Eugene Marquis, LTSI,UMR 1099, F-35000 Rennes, France
[2] CHU Brest, Radiotherapy Dept, F-29000 Brest, France
关键词
Parotid gland monitoring; Dose calculation; Density assignment; Dose-guided radiotherapy; Head-and-neck cancer; CONE-BEAM CT; DEFORMABLE IMAGE REGISTRATION; INTENSITY-MODULATED RADIOTHERAPY; ADAPTIVE RADIOTHERAPY; DOSIMETRIC CHANGES; RADIATION-THERAPY; ELECTRON-DENSITY; PAROTID-GLANDS; PLANNING CT; CBCT;
D O I
10.1007/s00066-018-1379-y
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purposeDuring head-and-neck (H&N) radiotherapy, the parotid glands (PGs) may be overdosed; thus, atool is required to monitor the delivered dose. This study aimed to assess the dose accuracy of apatient-specific density assignment method (DAM) for dose calculation to monitor the dose to PGs during treatment.Patients and methodsForty patients with H&N cancer received an intensity modulated radiation therapy (IMRT), among whom 15 had weekly CTs. Dose distributions were calculated either on the CTs (CTref), on one-class CTs (1C-CT, water), or on three-class CTs (3C-CT, water-air-bone). The inter- and intra-patient DAM uncertainties were evaluated by the difference between doses calculated on CTref and 1C-CTs or 3C-CTs. PG mean dose (D-mean) and spinal cord maximum dose (D-2%) were considered. The cumulated dose to the PGs was estimated by the mean D-mean of the weekly CTs.ResultsThe mean (maximum) inter-patient DAM dose uncertainties for the PGs (in cGy) were 23 (75) using 1C-CTs and 12 (50) using 3C-CTs (p0.001). For the spinal cord, these uncertainties were 118 (245) and 15 (67; p0.001). The mean (maximum) DAM dose uncertainty between cumulated doses calculated on CTs and 3C-CTs was 7cGy (45cGy) for the PGs. Considering the difference between the planned and cumulated doses, 53% of the ipsilateral and 80% of the contralateral PGs were overdosed by +3.6Gy (up to 8.2Gy) and +1.9Gy (up to 5.2Gy), respectively.ConclusionThe uncertainty of the three-class DAM appears to be clinically non-significant (<0.5Gy) compared with the PG overdose (up to 8.2Gy). This DAM could therefore be used to monitor PG doses and trigger replanning.
引用
收藏
页码:175 / 185
页数:11
相关论文
共 50 条
  • [1] A density assignment method for dose monitoring in head-and-neck radiotherapy; [Dichtezuordnungsmethode zur Dosisüberwachung bei der Strahlentherapie von Kopf-Hals-Tumoren]
    Barateau A.
    Perichon N.
    Castelli J.
    Schick U.
    Henry O.
    Chajon E.
    Simon A.
    Lafond C.
    De Crevoisier R.
    Strahlentherapie und Onkologie, 2019, 195 (2) : 175 - 185
  • [2] Accuracy of dose calculation on iterative CBCT for head and neck radiotherapy
    Washio, Hayate
    Ohira, Shingo
    Funama, Yoshinori
    Ueda, Yoshihiro
    Isono, Masaru
    Inui, Shoki
    Miyazaki, Masayoshi
    Teshima, Teruki
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 86 : 106 - 112
  • [3] Image-guided radiotherapy in head-and-neck oncology
    Balermpas, Panagiotis
    ONKOLOGIE, 2023, 29 (01): : 45 - 50
  • [4] Adaptive radiotherapy for head and neck cancer reduces the requirement for rescans during treatment due to spinal cord dose
    Belshaw, Louise
    Agnew, Christina E.
    Irvine, Denise M.
    Rooney, Keith P.
    McGarry, Conor K.
    RADIATION ONCOLOGY, 2019, 14 (01)
  • [5] Monitoring anatomical changes of individual patients using statistical process control during head-and-neck radiotherapy
    Lowther, Nicholas J.
    Hamilton, David A.
    Kim, Han
    Evans, Jamie M.
    Marsh, Steven H.
    Louwe, Robert J. W.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2019, 9 : 21 - 27
  • [6] High-dose hypofractionated radiotherapy is effective and safe for tumors in the head-and-neck
    Teckie, Sewit
    Lok, Benjamin H.
    Rao, Shyam
    Gutiontov, Stanley I.
    Yamada, Yoshiya
    Berry, Sean L.
    Zelefsky, Michael J.
    Lee, Nancy Y.
    ORAL ONCOLOGY, 2016, 60 : 74 - 80
  • [7] Online daily assessment of dose change in head and neck radiotherapy without dose-recalculation
    Vickress, Jason R.
    Battista, Jerry
    Barnett, Rob
    Yartsev, Slav
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (05): : 659 - 665
  • [8] Toward adaptive radiotherapy for head and neck patients: Feasibility study on using CT-to-CBCT deformable registration for "dose of the day" calculations
    Veiga, Catarina
    McClelland, Jamie
    Moinuddin, Syed
    Lourenco, Ana
    Ricketts, Kate
    Annkah, James
    Modat, Marc
    Ourselin, Sebastien
    D'Souza, Derek
    Royle, Gary
    MEDICAL PHYSICS, 2014, 41 (03)
  • [9] A Novel Method of 3-Dimensional Radiotherapy for Head-and-Neck Cancer Treatment
    Kim, Yong Nam
    Lee, Chang Geol
    Jeong, Kyoungkeun
    Kim, Joo Young
    Seong, Jinsil
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, : 302 - 305
  • [10] Adaptive intensity-modulated radiotherapy in head-and-neck cancer: A volumetric and dosimetric study
    Burela, Nagarjuna