Examiner repeatability of patellar cartilage T2 values

被引:15
作者
Koff, Matthew F. [1 ]
Parratte, Sebastien [1 ]
Amrami, Kimberly K. [2 ]
Kaufman, Kenton R. [1 ]
机构
[1] Mayo Clin, Dept Orthoped Surg, Rochester, MN 55901 USA
[2] Mayo Clin, Dept Radiol, Rochester, MN 55901 USA
基金
美国国家卫生研究院;
关键词
Reproducibility of results; MRI; Cartilage; Patella; JOINT SPACE WIDTH; RELAXATION-TIME MEASUREMENTS; HUMAN ARTICULAR-CARTILAGE; REGIONAL REPRODUCIBILITY; PATELLOFEMORAL JOINT; QUANTITATIVE MRI; IN-VIVO; OSTEOARTHRITIS; T2; KNEE;
D O I
10.1016/j.mri.2008.05.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim: The purpose of this Study was to evaluate the intra- and interexaminer resegmentation precision of patellar cartilage T-2 mapping measurements in healthy subjects. Materials and Methods: T-2-weighted images of patellar cartilage for 10 subjects were acquired. Two individuals manually segmented patellar cartilage at each slice location twice, once on each of two separate days. Bulk average and zonal T-2 values for the superficial, middle, and deep layers of cartilage were calculated. The root mean square (RMS) and coefficient of variation (COV) were calculated using the repeated measurements of each slice of each Subject by each examiner. Results: The intraexaminer bulk T-2 differences were 0.2 +/- 1.0 ms, with an RMS error of 0.7 ms and a COV of 1.9%. The differences of interexaminer bulk T-2 values was 1.0 +/- 1.4 ms, with an RMS error of 1.2 ms and a COV of 3.3%. The superficial zone of cartilage had the highest zonal variability of T-2 values. The average interexaminer T-2 values for the superficial, middle and deep zones were 42.2 +/- 5.6, 38.1 +/- 5.3 and 31.9 +/- 4.6 ms, respectively. Conclusion: The interexaminer variability of calculated T-2 values highlights the difficulty of interpreting significant differences of T-2 values which are similar in magnitude. The repeatability measurements of patellar cartilage T-2 values were less than reported intersession T-2 repeatability. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:131 / 136
页数:6
相关论文
共 28 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   Joint space width of the tibiofemoral and of the patellofemoral joint in chronic knee pain with or without radiographic osteoarthritis:: a 2-year follow-up [J].
Boegård, TL ;
Rudling, O ;
Petersson, IF ;
Jonsson, K .
OSTEOARTHRITIS AND CARTILAGE, 2003, 11 (05) :370-376
[3]   The burden of musculoskeletal disease - a global perspective [J].
Brooks, Peter M. .
CLINICAL RHEUMATOLOGY, 2006, 25 (06) :778-781
[4]  
BUCKLANDWRIGHT C, 1995, OSTEOARTHR CARTILAGE, V3, P71
[5]   Spatial variation of T2 in human articular cartilage [J].
Dardzinski, BJ ;
Mosher, TJ ;
Li, SZ ;
VanSlyke, MA ;
Smith, MB .
RADIOLOGY, 1997, 205 (02) :546-550
[6]   T2 relaxation time measurements in osteoarthritis [J].
David-Vaudey, E ;
Ghosh, S ;
Ries, M ;
Majumdar, S .
MAGNETIC RESONANCE IMAGING, 2004, 22 (05) :673-682
[7]   Measuring cartilage morphology with quantitative magnetic resonance imaging [J].
Eckstein, F ;
Glaser, C .
SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2004, 8 (04) :329-353
[8]  
ECKSTEIN F, 2006, OSTEOARTHRITIS CARTI
[9]   Quantitative MRI of cartilage and bone: degenerative changes in osteoarthritis [J].
Eckstein, Felix ;
Burstein, Deborah ;
Link, Thomas M. .
NMR IN BIOMEDICINE, 2006, 19 (07) :822-854
[10]   T2 relaxation time in patellar cartilage - Global and regional reproducibility at 1.5 Tesla and 3 Tesla [J].
Glaser, C. ;
Horng, A. ;
Mendlik, T. ;
Weckbach, S. ;
Hoffmann, R. -T. ;
Wagner, S. ;
Raya, J. G. ;
Horger, W. ;
Reiser, M. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2007, 179 (02) :146-152