3D Printed Microfluidic Device with Microporous Mn2O3-Modified Screen Printed Electrode for Real-Time Determination of Heavy Metal Ions

被引:97
作者
Hong, Ying [1 ,2 ,4 ]
Wu, Meiyan [1 ,2 ]
Chen, Guangwei [5 ]
Dai, Ziyang [1 ,2 ]
Zhang, Yizhou [1 ,2 ]
Chen, Guosong [3 ]
Dong, Xiaochen [1 ,2 ]
机构
[1] Nanjing Tech Univ NanjingTech, Jiangsu Natl Synerget Innovat Ctr Adv Mat SICAM, Key Lab Flexible Elect KLOFE, 30 South Puzhu Rd, Nanjing 211816, Jiangsu, Peoples R China
[2] Nanjing Tech Univ NanjingTech, Jiangsu Natl Synerget Innovat Ctr Adv Mat SICAM, Inst Adv Mat, 30 South Puzhu Rd, Nanjing 211816, Jiangsu, Peoples R China
[3] Nanjing Tech Univ NanjingTech, Coll Chem & Mol Engn, 30 South Puzhu Rd, Nanjing 211816, Jiangsu, Peoples R China
[4] Nanjing Entry Exit Inspect & Quarantine Bur, 1 Guojian Rd, Nanjing 211106, Jiangsu, Peoples R China
[5] Purdue Univ, Coll Elect & Comp Engn, W Lafayette, IN 47906 USA
关键词
3D printing; microfluidic device; microporous Mn2O3; screen printed electrode; heavy metal ions detection; ELECTROCHEMICAL DETECTION; COORDINATION POLYMER; ORGANIC FRAMEWORKS; HYDROGEN-PEROXIDE; CARBON; PERFORMANCE; WATER; DNA; PRECONCENTRATION; BATTERIES;
D O I
10.1021/acsami.6b10464
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Fabricating portable devices for the determination of heavy metal ions is an ongoing challenge. Here, a 3D printing approach was adopted to fabricate a microfluidic electrochemical sensor with the desired shape in which the model for velocity profiles in microfluidic cells was built and optimized by the finite element method (FEM). The electrode in the microfluidic cell was a flexible screen-printed electrode (SPE) modified with porous Mn2O3 derived from manganese containing metal-organic framework (Mn-MOF). The microfluidic device presented superior electrochemical detection properties toward heavy metal ions. The calibration curves at the modified SPE for Cd(II) and Pb(II) covered two linear ranges varying from 0.5 to 8 and 10 to 100 mu g L-1, respectively. The limits of detection were estimated to be 0.5 mu g L-1 for Cd(II) and 0.2 mu g L-1 for Pb(II), which were accordingly about 6 and 50 times lower than the guideline values proposed by the World Health Organization. Furthermore, the microfluidic device was connected to iPad via a USB to enable real-time household applications. Additionally, the sensing system exhibited a better stability and reproducibility compared with traditional detecting system which offered a promising prospect for the detection of heavy metal ions especially in household and resource-limited occasions.
引用
收藏
页码:32940 / 32947
页数:8
相关论文
共 42 条
  • [31] Agricultural waste material as potential adsorbent for sequestering heavy metal ions from aqueous solutions - A review
    Sud, Dhiraj
    Mahajan, Garima
    Kaur, M. P.
    [J]. BIORESOURCE TECHNOLOGY, 2008, 99 (14) : 6017 - 6027
  • [32] Mn2(2,5-disulfhydrylbenzene-1,4-dicarboxylate): A Microporous Metal-Organic Framework with Infinite (-Mn-S-)∞ Chains and High Intrinsic Charge Mobility
    Sun, Lei
    Miyakai, Tomoyo
    Seki, Shu
    Dinca, Mircea
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2013, 135 (22) : 8185 - 8188
  • [33] Symes MD, 2012, NAT CHEM, V4, P349, DOI [10.1038/NCHEM.1313, 10.1038/nchem.1313]
  • [34] ION-EXCHANGE SELECTIVITY OF NAFION FILMS ON ELECTRODE SURFACES
    SZENTIRMAY, MN
    MARTIN, CR
    [J]. ANALYTICAL CHEMISTRY, 1984, 56 (11) : 1898 - 1902
  • [35] Screen-printed electrodes for biosensing: a review (2008-2013)
    Taleat, Zahra
    Khoshroo, Alireza
    Mazloum-Ardakani, Mohammad
    [J]. MICROCHIMICA ACTA, 2014, 181 (9-10) : 865 - 891
  • [36] Fluorescent Imaging of Single Nanoparticles and Viruses on a Smart Phone
    Wei, Qingshan
    Qi, Hangfei
    Luo, Wei
    Tseng, Derek
    Ki, So Jung
    Wan, Zhe
    Gorocs, Zoltan
    Bentolila, Laurent A.
    Wu, Ting-Ting
    Sun, Ren
    Ozcan, Aydogan
    [J]. ACS NANO, 2013, 7 (10) : 9147 - 9155
  • [37] The origins and the future of microfluidics
    Whitesides, George M.
    [J]. NATURE, 2006, 442 (7101) : 368 - 373
  • [38] Simultaneous detection of Cd(II) and Pb(II) by differential pulse anodic stripping voltammetry at a nitrogen-doped microporous carbon/Nafion/bismuth-film electrode
    Xiao, Lili
    Xu, Hongbo
    Zhou, Shenghai
    Song, Ting
    Wang, Huanhuan
    Li, Shouzhu
    Gan, Wei
    Yuan, Qunhui
    [J]. ELECTROCHIMICA ACTA, 2014, 143 : 143 - 151
  • [39] The indirect electrochemical detection and quantification of DNA through its co-adsorption with anthraquinone monosulphonate on graphitic and multi-walled carbon nanotube screen printed electrodes
    Xiong, Linhongjia
    Batchelor-McAuley, Christopher
    Goncalves, Luis M.
    Rodrigues, Jose A.
    Compton, Richard G.
    [J]. BIOSENSORS & BIOELECTRONICS, 2011, 26 (10) : 4198 - 4203
  • [40] Fabrication and formation mechanism of Mn2O3 hollow nanofibers by single-spinneret electrospinning
    Yang, Guorui
    Yan, Wei
    Wang, Jianan
    Yang, Honghui
    [J]. CRYSTENGCOMM, 2014, 16 (30): : 6907 - 6913