Simulation of image performance of CZT detector for digital mammography

被引:0
|
作者
Alsager, Abdulaziz A. [1 ]
Spyrou, Nicholas M. [1 ]
机构
[1] Univ Surrey, Dept Phys, Guildford GU2 5XH, Surrey, England
关键词
CZT; modulation transfer function; detection quantum efficiency; Monte Carlo;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Hybrid pixel detector arrays that convert X-ray photons directly into electrical signal are still at the developmental stage for application to digital mammography. In this work, image performance of cadmium zinc telluride detector for digital mammography was investigated by the aid of Monte Carlo simulation. In order to evaluate the proposed detection system, a simulation of X-ray photon transport in the sensor material was conducted using the extended version of the Monte Carlo N-Particle (MCNPX) code. Detection quantum efficiency of the system was calculated and a comparison with other clinically available systems is reported.
引用
收藏
页码:1478 / 1483
页数:6
相关论文
共 50 条
  • [1] Evaluation of image performance of CZT detector for digital mammography: Monte Carlo simulation
    Alsager, A. A.
    Spyrou, N. M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 462 - 465
  • [2] Optimization of Image Quality in Digital Mammography with the Response of a Selenium Detector by Monte Carlo Simulation
    Szewczuk, Marek
    Konefal, Adam
    APPLIED SCIENCES-BASEL, 2023, 13 (01):
  • [3] Digital mammography: Performance considerations and current detector designs
    Williams, MB
    Fajardo, LL
    ACADEMIC RADIOLOGY, 1996, 3 (05) : 429 - 437
  • [4] Image quality of a prototype direct conversion detector for digital mammography
    Mainprize, JG
    Ford, NL
    Yin, S
    Tümer, T
    Yaffe, MJ
    MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 398 - 406
  • [5] Simulation and Measurement of Pixelated CZT Detector
    Fu, Jianqiang
    Li, Yulan
    Zhang, Lan
    Liu, Yilin
    Li, Jun
    Zhang, Wei
    Li, Yuanjing
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [6] Digital mammography image simulation using Monte Carlo
    Peplow, DE
    Verghese, K
    MEDICAL PHYSICS, 2000, 27 (03) : 568 - 579
  • [7] Monte Carlo Simulation of a CZT Detector
    Chun, Sung Dae
    Park, Se Hwan
    Ha, Jang Ho
    Kim, Han Soo
    Cho, Yoon Ho
    Kang, Sang Mook
    Kim, Yong Kyun
    Hong, Duk Geun
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, : 549 - 552
  • [8] Enhanced Molecular Breast Image quality through improved CZT detector performance
    Garcia, Timothy R.
    Kivenson, Aleksandr
    Malonson, Samuel
    Kudrolli, Hans
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [9] Performance evaluation of a retrofit digital detector-based mammography system
    Marshall, Nicholas W.
    van Ongeval, Chantal
    Bosmans, Hilde
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (02): : 312 - 322
  • [10] Direct conversion detector for digital mammography
    Polischuk, B
    Rougeot, H
    Wong, K
    Debrie, A
    Poliquin, E
    Hansroul, M
    Martin, JP
    Truong, TT
    Choquette, M
    Laperrière, L
    Shukri, Z
    MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 417 - 425