Locking plate fixation of humeral head fractures with a telescoping screw. A comparative biomechanical study versus a standard plate

被引:8
作者
Gradl, Gertraud [1 ,2 ]
Stedtfeld, Hans-Werner [1 ]
Morlock, Michael [3 ]
Sellenschloh, Kay [3 ]
Pueschel, Klaus [4 ]
Mittlmeier, Thomas [1 ]
Gradl, Georg [1 ]
机构
[1] Univ Rostock, Dept Trauma & Reconstruct Surg, D-18055 Rostock, Germany
[2] Univ Aachen, Dept Trauma Surg, Aachen, Germany
[3] Tech Univ Hamburg, Inst Biomech, Hamburg, Germany
[4] Univ Hamburg, Inst Legal Med, Hamburg, Germany
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2012年 / 43卷 / 06期
关键词
Locking plate; Proximal humerus; Cut out; Humeral head; Fracture; Penetration; PROXIMAL HUMERUS; SURGICAL NECK; INTRAMEDULLARY; OSTEOSYNTHESIS;
D O I
10.1016/j.injury.2011.08.012
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: Locking plate fixation of humeral head fractures bares the risk of glenohumeral screw penetration. In order to circumvent this problem it is recommended to insert shorter locking screws having at least a 6 mm distance to the humeral head cortex. This in turn may reduce fixation stability and may lead to early varus displacement. One second frequent failure mechanism is cranial displacement of the greater tubercle. The study evaluates the biomechanical properties of a locking plate employing an additional telescoping screw that may enhance resistance to varus displacement. Screw in screw fixation of the greater tubercle may reduce the rate of cranial displacement. Methods: In four paired fresh-frozen human cadaver humeri (age > 70 years) a Neer IV/3 fracture was created with a 5 mm osteotomy gap simulating metaphyseal comminution. Limbs were randomly assigned to receive plate fixation with an additional telescoping screw (Humerus Tele Screw: HTS) and on the contralateral limb Philos plate fixation before biomechanical evaluation (MTS-Bionix 858.2). Standard locking screws were placed in both groups 6 mm below the radiological head circumference; the telescoping screw was placed in the subchondral layer. The greater tubercle was fixed with an additional screw in both techniques, in the HTS group the screw was anchored in the sleeve of the telescrew (screw in screw fixation). Findings: Fixation stability with a mean stiffness of 300.9 +/- 28.8 N/mm in the HTS plate group proved to be significantly higher than in the Philos plate group (184.2 +/- 23.4 N/mm; p = 0.006). The HTS plate also resisted higher loads in terms of fixation failure with loss of reduction at 290 +/- 58.6 N in comparison to 205 +/- 8.6 N for the Philos plate (p = 0.2). Displacement of the greater tubercle occurred in no case of the HTS plate group and in two out of four cases in the Philos plate group. Interpretation: The HTS plate provides high fixation stability in an in vitro humeral head fracture model and securely prevents displacement of the greater tubercle. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:734 / 738
页数:5
相关论文
共 24 条
[1]   SURGICAL APPROACHES TO THE SHOULDER JOINT [J].
ABBOTT, LC ;
SAUNDERS, JBD ;
HAGEY, H ;
JONES, EW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1949, 31-A (02) :235-255
[2]   Analysis of efficacy and failure in proximal humerus fractures treated with locking plates [J].
Agudelo, Juan ;
Schuermann, Matthias ;
Stahel, Philip ;
Helwig, Peter ;
Morgan, Steven J. ;
Zechel, Wolfgang ;
Bahrs, Christian ;
Parekh, Anand ;
Ziran, Bruce ;
Williams, Allison ;
Smith, Wade .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (10) :676-681
[3]  
Baron JA, 1996, BONE, V18, P209
[4]  
Burkhead W, 1996, J SHOULDER ELB SURG, V1, P31
[5]  
COFIELD RH, 1988, CLIN ORTHOP RELAT R, P49
[6]   The epidemiology of proximal humeral fractures [J].
Court-Brown, CM ;
Garg, A ;
McQueen, MM .
ACTA ORTHOPAEDICA SCANDINAVICA, 2001, 72 (04) :365-371
[7]   A new locking plate for unstable fractures of the proximal humerus [J].
Fankhauser, F ;
Boldin, C ;
Schippinger, G ;
Haunschmid, C ;
Szyszkowitz, R .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (430) :176-181
[8]   The importance of medial support in locked plating of proximal humerus fractures [J].
Gardner, Michael J. ;
Weil, Yoram ;
Barker, Joseph U. ;
Kelly, Bryan T. ;
Helfet, David L. ;
Lorich, Dean G. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (03) :185-191
[9]   Locked plate fixation and intramedullary nailing for proximal humerus fractures: A biomechanical evaluation [J].
Hessmann, MH ;
Hansen, WSM ;
Krummenauer, F ;
Pol, TF ;
Rommens, M .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2005, 58 (06) :1194-1201
[10]   Are angle-fixed implants with elastic properties advantageous for the internal fixation of proximal humerus fractures? [J].
Hessmann, MH ;
Sternstein, W ;
Mehler, D ;
Korner, J ;
Hofmann, A ;
Rommens, PM .
BIOMEDIZINISCHE TECHNIK, 2004, 49 (12) :345-350