Multicriteria optimization informed VMAT planning

被引:27
作者
Chen, Huixiao [1 ]
Craft, David L. [1 ]
Gierga, David P. [1 ]
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Radiat Oncol, Boston, MA 02114 USA
关键词
MCO-IMRT; VMAT; Prostate; Head/neck; VOLUMETRIC-MODULATED ARC; SINGLE-ARC; THERAPY; IMRT; RADIOTHERAPY; QUALITY; DELIVERY; CANCER; NUMBER;
D O I
10.1016/j.meddos.2013.10.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
We developed a patient-specific volumetric-modulated arc therapy (VMAT) optimization procedure using dose-volume histogram (DVH) information from multicriteria optimization (MCO) of intensity-modulated radiotherapy (IMRT) plans. The study included 10 patients with prostate cancer undergoing standard fractionation treatment, 10 patients with prostate cancer undergoing hypofractionation treatment, and 5 patients with head/neck cancer. MCO-IMRT plans using 20 and 7 treatment fields were generated for each patient on the RayStation treatment planning system (clinical version 2.5, RaySearch Laboratories, Stockholm, Sweden). The resulting DVH of the 20-field MCO-IMRT plan for each patient was used as the reference DVH, and the extracted point values of the resulting DVH of the MCO-IMRT plan were used as objectives and constraints for VMAT optimization. Weights of objectives or constraints of VMAT optimization or both were further tuned to generate the best match with the reference DVH of the MCO-IMRT plan. The final optimal VMAT plan quality was evaluated by comparison with MCO-IMRT plans based on homogeneity index, conformity number of planning target volume, and organ at risk sparing. The influence of gantry spacing, arc number, and delivery time on VMAT plan quality for different tumor sites was also evaluated. The resulting VMAT plan quality essentially matched the 20-field MCO-IMRT plan but with a shorter delivery time and less monitor units. VMAT plan quality of head/neck cancer cases improved using dual arcs whereas prostate cases did not VMAT plan quality was improved by fine gantry spacing of 2 for the head/neck cancer cases and the hypofractionation-treated prostate cancer cases but not for the standard fractionation-treated prostate cancer cases. MCO-informed VMAT optimization is a useful and valuable way to generate patient-specific optimal VMAT plans, though modification of the weights of objectives or constraints extracted from resulting DVH of MCO-IMRT or both is necessary. (C) 2014 American Association of Medical Dosimetrists.
引用
收藏
页码:64 / 73
页数:10
相关论文
共 25 条
[1]   Evaluation of volumetric modulated arc therapy (VMAT) with Oncentra MasterPlan® for the treatment of head and neck cancer [J].
Alvarez-Moret, Judith ;
Pohl, Fabian ;
Koelbl, Oliver ;
Dobler, Barbara .
RADIATION ONCOLOGY, 2010, 5
[2]   CRITICAL APPRAISAL OF VOLUMETRIC MODULATED ARC THERAPY IN STEREOTACTIC BODY RADIATION THERAPY FOR METASTASES TO ABDOMINAL LYMPH NODES [J].
Bignardi, Mario ;
Cozzi, Luca ;
Fogliata, Antonella ;
Lattuada, Paola ;
Mancosu, Pietro ;
Navarria, Piera ;
Urso, Gaetano ;
Vigorito, Sabrina ;
Scorsetti, Marta .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (05) :1570-1577
[3]   Multicriteria optimization for volumetric-modulated arc therapy by decomposition into a fluence-based relaxation and a segment weight-based restriction [J].
Bokrantz, Rasmus .
MEDICAL PHYSICS, 2012, 39 (11) :6712-6725
[4]   The number of beams in IMRT-theoretical investigations and implications for single-arc IMRT [J].
Bortfeld, Thomas .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (01) :83-97
[5]   Single-Arc IMRT? [J].
Bortfeld, Thomas ;
Webb, Steve .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (01) :N9-N20
[6]   Development and evaluation of an efficient approach to volumetric arc therapy planning [J].
Bzdusek, Karl ;
Friberger, Henrik ;
Eriksson, Kjell ;
Hardemark, Bjorn ;
Robinson, David ;
Kaus, Michael .
MEDICAL PHYSICS, 2009, 36 (06) :2328-2339
[7]   A treatment planning study comparing volumetric arc modulation with RapidArc and fixed field IMRT for cervix uteri radiotherapy [J].
Cozzi, Luca ;
Dinshaw, Ketayun Ardeshir ;
Shrivastava, Shyam Kishore ;
Mahantshetty, Umesh ;
Engineer, Reena ;
Deshpande, Deepak Dattatray ;
Jamema, S. V. ;
Vanetti, Eugenio ;
Clivio, Alessandro ;
Nicolini, Giorgia ;
Fogliata, Antonella .
RADIOTHERAPY AND ONCOLOGY, 2008, 89 (02) :180-191
[8]  
Craft D., 2012, Physics in Medicine Biology, V58, P87
[9]   How many plans are needed in an IMRT multi-objective plan database? [J].
Craft, David ;
Bortfeld, Thomas .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (11) :2785-2796
[10]   An approach for practical multiobjective IMRT treatment planning [J].
Craft, David ;
Halabi, Tarek ;
Shih, Helen A. ;
Bortfeld, Thomas .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (05) :1600-1607