Quantitative Evaluations of Geometrical Distortion Corrections in Cortical Surface-Based Analysis of High-Resolution Functional MRI Data at 7T

被引:14
|
作者
Yamamoto, Tetsuya [1 ,2 ]
Fukunaga, Masaki [1 ,2 ]
Sugawara, Sho K. [1 ,2 ,3 ]
Hamano, Yuki H. [1 ]
Sadato, Norihiro [1 ,2 ]
机构
[1] Natl Inst Physiol Sci, Dept Syst Neurosci, Div Cerebral Integrat, Okazaki, Aichi, Japan
[2] Grad Sch Adv Studies SOKENDAI, Sch Life Sci, Dept Physiol Sci, Hayama, Kanagawa, Japan
[3] Tokyo Metropolitan Inst Med Sci, Neural Prosthesis Project, Dept Dementia & Higher Brain Funct, Tokyo, Japan
基金
日本学术振兴会;
关键词
geometrical distortion; B-0; inhomogeneity; gradient nonlinearity; ultra‐ high field MRI; cortical surface‐ based analysis; ECHO-PLANAR IMAGES; CEREBRAL-CORTEX; FMRI; ACTIVATION; THICKNESS; LAYERS;
D O I
10.1002/jmri.27420
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Although 7T functional MRI (fMRI) provides better signal-to-noise ratio and higher spatial resolution than 3T fMRI, geometric distortions become more challenging because fMRI is more susceptible to distortions than structural MRI. Accurate alignment of 7T fMRI to structural MRI data is critical for precise cortical surface-based analysis. Purpose To quantify the effectiveness of distortion corrections of 7T fMRI data. Study Type Prospective. Subjects Fifteen healthy individuals aged 19-26 years (mean: 21.9 years). Field Strength/Sequence Multiband gradient-echo echo-planar imaging sequence at 7T; 3D T-1/T-2-weighted sequences (magnetization prepared rapid acquisition with gradient echo [MPRAGE] and sampling perfection with application optimized contrast using different flip angle evolution [SPACE]) at 3T. Assessment fMRI data at 7T were registered to cortical surfaces reconstructed from 3T structural data acquired in the same subjects. Distortions induced by B-0 inhomogeneity and gradient nonlinearity (B-0 and gradient distortions) were evaluated as cortical fallout (misregistration of noncortical areas) and displacement (misregistration along gray matter). Statistical Tests Repeated measures analyses of variance with post-hoc t-tests with Bonferroni correction. Results The accuracy of fully corrected fMRI images based on the intensity distribution was 89.2%. Without any corrections, 9.7% of vertices in the whole surfaces were fallout and the average displacement was 0.96 mm for the rest of the vertices. B-0 and gradient distortion corrections significantly reduced the fallout (to 2.1% and 8.7%) and displacement (to 0.29 mm and 0.86 mm). These corrections were effective even around regions with moderate distortions (the somatosensory and visual cortices for B-0 distortion, and the anterior frontal, inferior temporal, and posterior occipital cortices for gradient distortion). Data Conclusion B-0 distortion correction is crucial for surface-based analysis of fine-resolution fMRI at 7T. Gradient distortion correction should be considered when regions of interest include regions distant from the isocenter of scanners. Evidence Level 1 Technical Efficacy Stage 1
引用
收藏
页码:1220 / 1234
页数:15
相关论文
共 50 条
  • [41] Selective activation of mesoscale functional circuits via multichannel infrared stimulation of cortical columns in ultra-high-field 7T MRI
    Tian, Feiyan
    Liu, Yipeng
    Chen, Meixuan
    Schriver, Kenneth Edward
    Roe, Anna Wang
    CELL REPORTS METHODS, 2025, 5 (01):
  • [42] Knee cartilage measurements during maturation and osteoarthritis follow-up using 7T high-resolution MRI:: an in vivo study in the rat
    Goebel, J. C.
    Bolbos, R.
    Pinzano, A.
    Galois, L.
    Etienne, S.
    Schaeffer, M.
    Rengle, A.
    Netter, P.
    Loeuille, D.
    Gillet, P.
    FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2007, 21 : 74 - 74
  • [43] 3D grating-based X-ray phase-contrast computed tomography for high-resolution quantitative assessment of cartilage: An experimental feasibility study with 3T MRI, 7T MRI and biomechanical correlation
    Herzen, Julia
    Karampinos, Dimitrios C.
    Foehr, Peter
    Birnbacher, Lorenz
    Viermetz, Manuel
    Burgkart, Rainer
    Baum, Thomas
    Lohoefer, Fabian
    Wildgruber, Moritz
    Schilling, Franz
    Willner, Marian
    Marschner, Mathias
    Noel, Peter B.
    Rummeny, Ernst J.
    Pfeiffer, Franz
    Jungmann, Pia M.
    PLOS ONE, 2019, 14 (02):
  • [44] High-resolution metabolic mapping of gliomas via patch-based super-resolution magnetic resonance spectroscopic imaging at 7T
    Hangel, Gilbert
    Jain, Saurabh
    Springer, Elisabeth
    Heckova, Eva
    Strasser, Bernhard
    Povazan, Michal
    Gruber, Stephan
    Widhalm, Georg
    Kiesel, Barbara
    Furtner, Julia
    Preusser, Matthias
    Roetzer, Thomas
    Trattnig, Siegfried
    Sima, Diana M.
    Smeets, Dirk
    Bogner, Wolfgang
    NEUROIMAGE, 2019, 191 : 587 - 595
  • [45] Assessment of arterial pulsatility of cerebral perforating arteries using 7T high-resolution dual-VENC phase-contrast MRI
    Tang, Jianing
    Pahlavian, Soroush Heidari
    Joe, Elizabeth
    Gamez, Maria Tereza
    Zhao, Tianrui
    Ma, Samantha J.
    Jin, Jin
    Cen, Steven Yong
    Chui, Helena C.
    Yan, Lirong
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (02) : 605 - 617
  • [46] High resolution functional mapping of upper and lower limb sensorimotor function in minimally disabled people with multiple sclerosis using 7t mri
    Strik, M.
    Shanahan, C.
    Van Der Walt, A.
    Boonstra, F.
    Glarin, R.
    Galea, M.
    Kilpatrick, T.
    Geurts, J.
    Schoonheim, M.
    Kolbe, S.
    MULTIPLE SCLEROSIS JOURNAL, 2020, 26 (3_SUPPL) : 396 - 396
  • [47] Investigation of high-resolution functional magnetic resonance imaging by means of surface and array radiofrequency coils at 7 T
    van der Zwaag, Wietske
    Marques, Jose P.
    Hergt, Martin
    Gruetter, Rolf
    MAGNETIC RESONANCE IMAGING, 2009, 27 (08) : 1011 - 1018
  • [48] High-resolution water content estimation from surface-based ground-penetrating radar reflection data by impedance inversion
    Schmelzbach, C.
    Tronicke, J.
    Dietrich, P.
    WATER RESOURCES RESEARCH, 2012, 48
  • [49] A Histology-Based Model of Quantitative T1 Contrast for In-vivo Cortical Parcellation of High-Resolution 7 Tesla Brain MR Images
    Dinse, Juliane
    Waehnert, Miriam
    Tardif, Christine Lucas
    Schaefer, Andreas
    Geyer, Stefan
    Turner, Robert
    Bazin, Pierre-Louis
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2013, PT II, 2013, 8150 : 51 - 58
  • [50] Surface-based functional magnetic resonance imaging analysis of partial brain echo planar imaging data at 1.5 T
    Jo, Hang Joon
    Lee, Jong-Min
    Kim, Jae-Hun
    Choi, Chi-Hoon
    Kang, Do-Hyung
    Kwon, Jun Soo
    Kim, Sun I.
    MAGNETIC RESONANCE IMAGING, 2009, 27 (05) : 691 - 700