Quantitative Evaluations of Geometrical Distortion Corrections in Cortical Surface-Based Analysis of High-Resolution Functional MRI Data at 7T

被引:14
|
作者
Yamamoto, Tetsuya [1 ,2 ]
Fukunaga, Masaki [1 ,2 ]
Sugawara, Sho K. [1 ,2 ,3 ]
Hamano, Yuki H. [1 ]
Sadato, Norihiro [1 ,2 ]
机构
[1] Natl Inst Physiol Sci, Dept Syst Neurosci, Div Cerebral Integrat, Okazaki, Aichi, Japan
[2] Grad Sch Adv Studies SOKENDAI, Sch Life Sci, Dept Physiol Sci, Hayama, Kanagawa, Japan
[3] Tokyo Metropolitan Inst Med Sci, Neural Prosthesis Project, Dept Dementia & Higher Brain Funct, Tokyo, Japan
基金
日本学术振兴会;
关键词
geometrical distortion; B-0; inhomogeneity; gradient nonlinearity; ultra‐ high field MRI; cortical surface‐ based analysis; ECHO-PLANAR IMAGES; CEREBRAL-CORTEX; FMRI; ACTIVATION; THICKNESS; LAYERS;
D O I
10.1002/jmri.27420
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Although 7T functional MRI (fMRI) provides better signal-to-noise ratio and higher spatial resolution than 3T fMRI, geometric distortions become more challenging because fMRI is more susceptible to distortions than structural MRI. Accurate alignment of 7T fMRI to structural MRI data is critical for precise cortical surface-based analysis. Purpose To quantify the effectiveness of distortion corrections of 7T fMRI data. Study Type Prospective. Subjects Fifteen healthy individuals aged 19-26 years (mean: 21.9 years). Field Strength/Sequence Multiband gradient-echo echo-planar imaging sequence at 7T; 3D T-1/T-2-weighted sequences (magnetization prepared rapid acquisition with gradient echo [MPRAGE] and sampling perfection with application optimized contrast using different flip angle evolution [SPACE]) at 3T. Assessment fMRI data at 7T were registered to cortical surfaces reconstructed from 3T structural data acquired in the same subjects. Distortions induced by B-0 inhomogeneity and gradient nonlinearity (B-0 and gradient distortions) were evaluated as cortical fallout (misregistration of noncortical areas) and displacement (misregistration along gray matter). Statistical Tests Repeated measures analyses of variance with post-hoc t-tests with Bonferroni correction. Results The accuracy of fully corrected fMRI images based on the intensity distribution was 89.2%. Without any corrections, 9.7% of vertices in the whole surfaces were fallout and the average displacement was 0.96 mm for the rest of the vertices. B-0 and gradient distortion corrections significantly reduced the fallout (to 2.1% and 8.7%) and displacement (to 0.29 mm and 0.86 mm). These corrections were effective even around regions with moderate distortions (the somatosensory and visual cortices for B-0 distortion, and the anterior frontal, inferior temporal, and posterior occipital cortices for gradient distortion). Data Conclusion B-0 distortion correction is crucial for surface-based analysis of fine-resolution fMRI at 7T. Gradient distortion correction should be considered when regions of interest include regions distant from the isocenter of scanners. Evidence Level 1 Technical Efficacy Stage 1
引用
收藏
页码:1220 / 1234
页数:15
相关论文
共 50 条
  • [31] The link between subpial and diffuse white matter pathology in MS: a multimodal 7T and 3T MRI study using a surface-based and a tract-based analysis
    Louapre, C.
    Govindarajan, S. T.
    Gianni, C.
    Cohen-Adad, J.
    Kinkel, R. P.
    Mainero, C.
    MULTIPLE SCLEROSIS JOURNAL, 2014, 20 : 260 - 260
  • [32] High-resolution velocity estimation from surface-based common-offset GPR reflection data
    Liu, Yu
    Irving, James
    Holliger, Klaus
    GEOPHYSICAL JOURNAL INTERNATIONAL, 2022, 230 (01) : 131 - 144
  • [33] Knee cartilage measurements during maturation using 7T High-Resolution MRI (HR-MRI): An in vivo study in the rat.
    Goebel, Jean Christophe
    Bolbos, Radu
    Etienne, Stephanie
    Pinzano-Watrin, Astrid
    Schaeffer, Mathilde
    Galois, Laurent
    Rengle, Adrian
    Netter, Patrick
    Beuf, Olivier
    Gillet, Pierre
    ARTHRITIS AND RHEUMATISM, 2006, 54 (09): : S626 - S627
  • [34] Automatic cortical surface reconstruction of high-resolution T1 echo planar imaging data
    Renvall, Ville
    Witzel, Thomas
    Wald, Lawrence L.
    Polimeni, Jonathan R.
    NEUROIMAGE, 2016, 134 : 338 - 354
  • [35] Robust functional mapping of layer-selective responses in human lateral geniculate nucleus with high-resolution 7T fMRI
    Qian, Yazhu
    Zou, Jinyou
    Zhang, Zihao
    An, Jing
    Zuo, Zhentao
    Zhuo, Yan
    Wang, Danny J. J.
    Zhang, Peng
    PROCEEDINGS OF THE ROYAL SOCIETY B-BIOLOGICAL SCIENCES, 2020, 287 (1925)
  • [36] Phase-based fast 3D high-resolution quantitative T2 MRI in 7 T human brain imaging
    Seginer, Amir
    Schmidt, Rita
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [37] Quantitative Analysis Using High-Resolution 3T MRI in Acute Intracranial Artery Dissection
    Jung, Seung Chai
    Kim, Ho Sung
    Choi, Choong-Gon
    Kim, Sang Joon
    Lee, Deok Hee
    Suh, Dae Chul
    Kwon, Sun U.
    Kang, Dong-Wha
    Kim, Jong S.
    JOURNAL OF NEUROIMAGING, 2016, 26 (06) : 612 - 617
  • [38] Phase-based fast 3D high-resolution quantitative T2 MRI in 7 T human brain imaging
    Amir Seginer
    Rita Schmidt
    Scientific Reports, 12
  • [39] Quantitative high-resolution 7T MRI to assess longitudinal changes in articular cartilage after anterior cruciate ligament injury in a rabbit model of post-traumatic osteoarthritis
    Terracciano, Rossana
    Carcamo-Bahena, Yareli
    Royal, Amber Lee R.
    Demarchi, Danilo
    Labis, John Scott
    Harris, Joshua D.
    Weiner, Bradley K.
    Gupta, Nakul
    Filgueira, Carly S.
    OSTEOARTHRITIS AND CARTILAGE OPEN, 2022, 4 (02):
  • [40] Planation surface extraction and quantitative analysis based on high-resolution digital elevation models
    Wang, YX
    Pan, BT
    Gao, HS
    Liu, Y
    IGARSS 2005: IEEE International Geoscience and Remote Sensing Symposium, Vols 1-8, Proceedings, 2005, : 5369 - 5371