Quantitative Evaluations of Geometrical Distortion Corrections in Cortical Surface-Based Analysis of High-Resolution Functional MRI Data at 7T

被引:14
|
作者
Yamamoto, Tetsuya [1 ,2 ]
Fukunaga, Masaki [1 ,2 ]
Sugawara, Sho K. [1 ,2 ,3 ]
Hamano, Yuki H. [1 ]
Sadato, Norihiro [1 ,2 ]
机构
[1] Natl Inst Physiol Sci, Dept Syst Neurosci, Div Cerebral Integrat, Okazaki, Aichi, Japan
[2] Grad Sch Adv Studies SOKENDAI, Sch Life Sci, Dept Physiol Sci, Hayama, Kanagawa, Japan
[3] Tokyo Metropolitan Inst Med Sci, Neural Prosthesis Project, Dept Dementia & Higher Brain Funct, Tokyo, Japan
基金
日本学术振兴会;
关键词
geometrical distortion; B-0; inhomogeneity; gradient nonlinearity; ultra‐ high field MRI; cortical surface‐ based analysis; ECHO-PLANAR IMAGES; CEREBRAL-CORTEX; FMRI; ACTIVATION; THICKNESS; LAYERS;
D O I
10.1002/jmri.27420
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Although 7T functional MRI (fMRI) provides better signal-to-noise ratio and higher spatial resolution than 3T fMRI, geometric distortions become more challenging because fMRI is more susceptible to distortions than structural MRI. Accurate alignment of 7T fMRI to structural MRI data is critical for precise cortical surface-based analysis. Purpose To quantify the effectiveness of distortion corrections of 7T fMRI data. Study Type Prospective. Subjects Fifteen healthy individuals aged 19-26 years (mean: 21.9 years). Field Strength/Sequence Multiband gradient-echo echo-planar imaging sequence at 7T; 3D T-1/T-2-weighted sequences (magnetization prepared rapid acquisition with gradient echo [MPRAGE] and sampling perfection with application optimized contrast using different flip angle evolution [SPACE]) at 3T. Assessment fMRI data at 7T were registered to cortical surfaces reconstructed from 3T structural data acquired in the same subjects. Distortions induced by B-0 inhomogeneity and gradient nonlinearity (B-0 and gradient distortions) were evaluated as cortical fallout (misregistration of noncortical areas) and displacement (misregistration along gray matter). Statistical Tests Repeated measures analyses of variance with post-hoc t-tests with Bonferroni correction. Results The accuracy of fully corrected fMRI images based on the intensity distribution was 89.2%. Without any corrections, 9.7% of vertices in the whole surfaces were fallout and the average displacement was 0.96 mm for the rest of the vertices. B-0 and gradient distortion corrections significantly reduced the fallout (to 2.1% and 8.7%) and displacement (to 0.29 mm and 0.86 mm). These corrections were effective even around regions with moderate distortions (the somatosensory and visual cortices for B-0 distortion, and the anterior frontal, inferior temporal, and posterior occipital cortices for gradient distortion). Data Conclusion B-0 distortion correction is crucial for surface-based analysis of fine-resolution fMRI at 7T. Gradient distortion correction should be considered when regions of interest include regions distant from the isocenter of scanners. Evidence Level 1 Technical Efficacy Stage 1
引用
收藏
页码:1220 / 1234
页数:15
相关论文
共 50 条
  • [1] Editorial for "Quantitative Evaluations of Geometrical Distortion Corrections in Cortical Surface-Based Analysis of High-Resolution Functional MRI Data at 7T"
    Zou, Xiaowei
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 53 (04) : 1235 - 1236
  • [2] In vivo detection of cerebral cortical microinfarcts with high-resolution 7T MRI
    van Veluw, Susanne J.
    Zwanenburg, Jaco J. M.
    Engelen-Lee, JooYeon
    Spliet, Wim G. M.
    Hendrikse, Jeroen
    Luijten, Peter R.
    Biessels, Geert Jan
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2013, 33 (03): : 322 - 329
  • [3] Longitudinal Analysis of Cortical Demyelination in Multiple Sclerosis (MS) Using Multimodal High-Resolution 7T MRI
    Beck, Erin S.
    Maranzano, Josefina
    Sati, Pascal
    Filippini, Stefano
    Morrison, Mark
    Luciano, Nicholas J.
    Suto, Daniel J.
    Cortese, Irene
    Narayanan, Sridar
    Reich, Daniel S.
    ANNALS OF NEUROLOGY, 2020, 88 : S53 - S53
  • [4] High-Resolution 7T MRI of the Human Hippocampus In Vivo
    Thomas, Bradley P.
    Welch, E. Brian
    Niederhauser, Blake D.
    Whetsell, William O., Jr.
    Anderson, Adam W.
    Gore, John C.
    Avison, Malcolm J.
    Creasy, Jeffrey L.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (05) : 1266 - 1272
  • [5] High-Resolution Diffusion MRI Of The Trigeminal Nerve Using 7T MRI
    Lenglet, Christophe
    Sein, Julien
    Tokarev, Julian
    Grande, Andrew
    Jagadeesan, Bharathi
    van de Moortele, Pierre-Francois
    JOURNAL OF NEUROSURGERY, 2013, 119 (02) : A566 - A566
  • [6] Surface-based analysis methods for high-resolution functional magnetic resonance imaging
    Khan, Rez
    Zhang, Qin
    Darayan, Shayan
    Dhandapani, Sankari
    Katyal, Sucharit
    Greene, Clint
    Bajaj, Chandra
    Ress, David
    GRAPHICAL MODELS, 2011, 73 : 313 - 322
  • [7] Assessment of perilesional pathology in cortical and leukocortical lesions in MS by ultra high resolution quantitative 7T MRI
    Louapre, C.
    Govindaraja, S. T.
    Gianni, C.
    Sloane, J. A.
    Kinkel, R. P.
    Mainero, C.
    MULTIPLE SCLEROSIS JOURNAL, 2015, 21 : 13 - 13
  • [8] High-resolution functional MRI of the human amygdala at 7 T
    Sladky, Ronald
    Baldinger, Pia
    Kranz, Georg S.
    Troestl, Jasmin
    Hoeflich, Anna
    Lanzenberger, Rupert
    Moser, Ewald
    Windischberger, Christian
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (05) : 728 - 733
  • [9] Evaluation of the whole auditory pathway using high-resolution and functional MRI at 7T parallel-transmit
    Da Costa, Sandra
    Clement, Jeremie
    Gruetter, Rolf
    Ipek, Ozlem
    PLOS ONE, 2021, 16 (09):
  • [10] High-Resolution Vessel Wall Imaging of Cryptogenic Stroke: A 7T MRI Study
    Roa, Jorge A.
    Zanaty, Mario
    Ishii, Daizo
    Derdeyn, Colin P.
    Bathla, Girish
    Limaye, Kaustubh
    Ortega-Gutierrez, Santiago
    Hasan, David M.
    Samaniego, Edgar A.
    STROKE, 2020, 51