Ozone removal by occupants in a classroom

被引:54
作者
Fischer, Andreas [1 ]
Ljungstrom, Evert [1 ]
Langer, Sarka [1 ,2 ]
机构
[1] Univ Gothenburg, Dept Chem & Mol Biol, SE-41296 Gothenburg, Sweden
[2] SP Tech Res Inst Sweden, Dept Chem & Mat Technol, SE-50115 Boras, Sweden
基金
瑞典研究理事会;
关键词
Squalene; 4-Oxopentanal; Ozone; Deposition velocity; Indoor environment; School; INDOOR AIR CHEMISTRY; BUILDING PRODUCTS; DEPOSITION VELOCITIES; INITIATED CHEMISTRY; SKIN LIPIDS; SURFACE; RATES; HEALTH; ENVIRONMENTS; DIRECTIONS;
D O I
10.1016/j.atmosenv.2013.08.054
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Ozone concentrations were measured in a classroom with and without occupants, with the purpose to quantify effects on indoor 03 concentrations. The teacher and 24 11-year old pupils each removed 03 at a rate, first order in O-3, corresponding to a rate constant of (2.5 +/- 0.6) x 10(-5) s(-1) in the present locality and to a deposition velocity of 0.45 cm s(-1). The O-3-removal caused by the occupants was approximately 2.6 times larger than that of the available surfaces belonging to the classroom and its furniture. Observation of 6-methyl-5-hepten-2-one and 4-oxopentanal at maximum concentrations of 0.2 ppb and 0.7 ppb, respectively, suggested squalene from human skin oil as a reactive, ozone-consuming substance. There are indications of a source of 4-oxopentanal in the classroom, even some time after the pupils left for the day. The work presented is important for a proper description of indoor exposure, both to ozone itself and some of its reaction products when trying to quantify relations between exposure and health effects. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:11 / 17
页数:7
相关论文
共 50 条
[11]   Ozone consumption and volatile byproduct formation from surface reactions with aircraft cabin materials and clothing fabrics [J].
Coleman, Beverly K. ;
Destaillats, Hugo ;
Hodgson, Alfred T. ;
Nazaroff, William W. .
ATMOSPHERIC ENVIRONMENT, 2008, 42 (04) :642-654
[12]   Chemistry and indoor air quality in a multi-storey wooden passive (low energy) building: Formation of peroxyacetyl nitrate [J].
Fischer, A. ;
Langer, S. ;
Ljungstrom, E. .
INDOOR AND BUILT ENVIRONMENT, 2014, 23 (03) :485-496
[13]   Ozonolysis at vegetation surfaces: A source of acetone, 4-oxopentanal, 6-methyl-5-hepten-2-one, and geranyl acetone in the troposphere [J].
Fruekilde, P ;
Hjorth, J ;
Jensen, NR ;
Kotzias, D ;
Larsen, B .
ATMOSPHERIC ENVIRONMENT, 1998, 32 (11) :1893-1902
[14]   Compilation of tables of surface deposition velocities for O3, NO2 and SO2 to a range of indoor surfaces [J].
Grontoft, T ;
Raychaudhuri, MR .
ATMOSPHERIC ENVIRONMENT, 2004, 38 (04) :533-544
[15]  
Grosjean E, 1996, INT J CHEM KINET, V28, P373, DOI 10.1002/(SICI)1097-4601(1996)28:5<373::AID-KIN6>3.0.CO
[16]  
2-S
[17]   GEOMETRIC METHOD FOR MEASURING BODY-SURFACE AREA - HEIGHT-WEIGHT FORMULA VALIDATED IN INFANTS, CHILDREN, AND ADULTS [J].
HAYCOCK, GB ;
SCHWARTZ, GJ ;
WISOTSKY, DH .
JOURNAL OF PEDIATRICS, 1978, 93 (01) :62-66
[18]   Ozone removal by green building materials [J].
Hoang, Chi P. ;
Kinney, Kerry A. ;
Corsi, Richard L. .
BUILDING AND ENVIRONMENT, 2009, 44 (08) :1627-1633
[19]   PREDICTION OF GAS-CHROMATOGRAPHIC RETENTION TIMES AND RESPONSE FACTORS USING A GENERAL QUANTITATIVE STRUCTURE-PROPERTY RELATIONSHIP TREATMENT [J].
KATRITZKY, AR ;
IGNATCHENKO, ES ;
BARCOCK, RA ;
LOBANOV, VS ;
KARELSON, M .
ANALYTICAL CHEMISTRY, 1994, 66 (11) :1799-1807
[20]   Determination of ozone removal rates by selected building products using the FLEC emission cell [J].
Kleno, JG ;
Clausen, PA ;
Weschler, CJ ;
Wolkoff, P .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (12) :2548-2553