Signal-to-noise ratios in forensic glass analysis by micro X-ray fluorescence spectrometry

被引:40
|
作者
Ernst, T. [1 ]
Berman, T. [2 ]
Buscaglia, J. [3 ]
Eckert-Lumsdon, T. [4 ]
Hanlon, C. [5 ]
Olsson, K. [6 ]
Palenik, C. [7 ]
Ryland, S. [2 ]
Trejos, T. [8 ,9 ]
Valadez, M. [10 ]
Almirall, J. R. [8 ,9 ]
机构
[1] Michigan State Police Grand Rapids Lab, Trace Evidence Unit, Grand Rapids, MI 49503 USA
[2] Florida Dept Law Enforcement, Orlando Reg Operat Ctr, Orlando, FL USA
[3] Fed Bur Invest Lab, Counterterrorism & Forens Sci Res Unit, Quantico, VA USA
[4] US Army Criminal Invest Lab, Trace Evidence Branch, Forest Pk, GA USA
[5] Miami Dade Police Dept, Miami, FL USA
[6] Johnson Cty Crime Lab, Olathe, KS USA
[7] Microtrace LLC, Elgin, IL USA
[8] Florida Int Univ, Dept Chem & Biochem, Miami, FL 33199 USA
[9] Florida Int Univ, Int Forens Res Inst, Miami, FL 33199 USA
[10] Texas Dept Publ Safety, Crime Lab, Austin, TX USA
关键词
DISCRIMINATION; FRAGMENTS;
D O I
10.1002/xrs.2437
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Micro X-ray fluorescence (-XRF) spectrometry using an energy dispersive X-ray (EDS) detector is capable of detecting certain major, minor, and trace elements that permit potential discrimination of glass fragments in forensic cases on the basis of differences in elemental composition. Often, elements used for discrimination are present at concentrations near the detection limit of the EDS system, and the decision whether to utilize these minor peaks in a comparative analysis has generally been left to the discretion of the examiner. The use of signal-to-noise ratios (SNRs) of spectral peaks provides additional objectivity in peak identification/label decisions and in the selection of elements in semiquantitative ratio comparisons. In addition, the use of SNRs enables calculations of limits of detection and limits of quantitation and the monitoring of instrument performance, and facilitates performance comparisons of different -XRF configurations. This paper demonstrates a practical method for applying the concepts of SNR, limits of detection, and limits of quantitation to -XRF generated EDS-based spectra, discusses the implications of such determinations, addresses spectral features that must be considered when making the calculations, and illustrates the application of these concepts to the example of forensic examination and comparison of glass samples. Copyright (c) 2012 John Wiley & Sons, Ltd.
引用
收藏
页码:13 / 21
页数:9
相关论文
共 50 条
  • [1] Improving signal-to-noise ratio for the forensic analysis of glass using micro X-ray fluorescence spectrometry
    Corzo, Ruthmara
    Steel, Eric
    X-RAY SPECTROMETRY, 2020, 49 (06) : 679 - 689
  • [2] Signal-to-noise ratio optimization in X-ray fluorescence spectrometry for chromium contamination analysis
    An, Siwen
    Reza, Salim
    Norlin, Borje
    Frojdh, Christer
    Thungstrom, Goran
    TALANTA, 2021, 230
  • [3] Optimal signal-to-noise ratios for soft x-ray lensless imaging
    Rick, R.
    Scherz, A.
    Schlotter, W. F.
    Zhu, D.
    Luening, J.
    Stoehr, J.
    OPTICS LETTERS, 2009, 34 (05) : 650 - 652
  • [4] Evaluation of the performance of modern X-ray fluorescence spectrometry systems for the forensic analysis of glass
    Corzo, Ruthmara
    Ernst, Troy
    Insana, Joseph
    Martinez-Lopez, Claudia
    Webb, Jodi
    Haase, Emily
    Weis, Peter
    Trejos, Tatiana
    FORENSIC CHEMISTRY, 2022, 31
  • [5] Optimizing signal-to-noise on a home X-ray source for the analysis of microcrystals
    Frankel, Daniel C.
    Lancaster, Robert
    Michell, Brian
    Storm, Arjen
    Burkholder, Rick
    von Delft, Frank
    Murray, James
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2008, 64 : C172 - C172
  • [6] REVIEW AND TUTORIAL DISCUSSION OF NOISE AND SIGNAL-TO-NOISE RATIOS IN ANALYTICAL SPECTROMETRY .1. FUNDAMENTAL PRINCIPLES OF SIGNAL-TO-NOISE RATIOS
    ALKEMADE, CTJ
    SNELLEMAN, W
    BOUTILIER, GD
    POLLARD, BD
    WINEFORDNER, JD
    CHESTER, TL
    OMENETTO, N
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1978, 33 (08) : 383 - 399
  • [7] REVIEW AND TUTORIAL DISCUSSION OF NOISE AND SIGNAL-TO-NOISE RATIOS IN ANALYTICAL SPECTROMETRY .2. FUNDAMENTAL PRINCIPLES OF SIGNAL-TO-NOISE RATIOS
    BOUTILIER, GD
    POLLARD, BD
    WINEFORDNER, JD
    CHESTER, TL
    OMENETTO, N
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1978, 33 (08) : 401 - 416
  • [8] Fundamental characteristics of polycapillary x-ray optics combined with glass conical pinhole for micro x-ray fluorescence spectrometry
    Matsuda, Akinori
    Nakano, Kazuhiko
    Komatani, Shintaro
    Ohzawa, Sumito
    Uchihara, Hiroshi
    Tsuji, Kouichi
    X-RAY SPECTROMETRY, 2009, 38 (03) : 258 - 262
  • [9] Computations of the Signal-to-Noise Ratio for Medical X-Ray Imagers
    Lo, Yu-Chen
    Huang, Kuan-Chieh
    Yang, Kei-Hsiung
    CHINESE JOURNAL OF PHYSICS, 2014, 52 (04) : 1277 - 1287
  • [10] SIGNAL-TO-NOISE MEASUREMENTS IN X-RAY PHOTOELECTRON-SPECTROSCOPY
    KOENIG, MF
    GRANT, JT
    SURFACE AND INTERFACE ANALYSIS, 1985, 7 (05) : 217 - 222