Flow and diffusion of water in natural porous media, quartz sand, and calcareous gravel were measured using a 1.5-T clinical magnetic resonance tomograph. The spatial resolution of the dynamic measurements was 1.32 X 1.32 X 5 mm(3) and the time between two cross-sectional measurements was approximately 10 s. The measured coefficients of molecular diffusion for water were in good agreement with theoretical data. Flow was measured without any tracer at velocities between 0.15 and 6.67 mm/s. The results, based on a calibration within one part of the column, were in good agreement with data obtained from a tracer experiment and from a numerical model. It was possible to measure the flow velocity in larger pores and preferential flow paths directly. The results of the flow, measurements in smaller pores reflected the mean velocity within that volume element. In that case the obtained values were close to the average linear velocity. Since the time resolution is high a monitoring of now processes is possible. The pore space was imaged with a spatial resolution of 0.5 X 0.5 X 0.5 mm(3). Here, the porosity of pores that are larger than 0.2 mm can be measured directly; for smaller pores a calibration is necessary.
引用
收藏
页码:470 / 476
页数:7
相关论文
共 50 条
  • [1] Water Flow Monitored by Tracer Transport in Natural Porous Media Using Magnetic Resonance Imaging
    Haber-Pohlmeier, S.
    Bechtold, M.
    Stapf, S.
    Pohlmeier, A.
    VADOSE ZONE JOURNAL, 2010, 9 (04): : 835 - 845
  • [2] QUANTITATIVE MAGNETIC-RESONANCE FLOW AND DIFFUSION IMAGING IN POROUS-MEDIA
    RAJANAYAGAM, V
    YAO, SG
    POPE, JM
    MAGNETIC RESONANCE IMAGING, 1995, 13 (05) : 729 - 738
  • [3] Monitoring bacterially induced calcite precipitation in porous media using magnetic resonance imaging and flow measurements
    Sham, E.
    Mantle, M. D.
    Mitchell, J.
    Tobler, D. J.
    Phoenix, V. R.
    Johns, M. L.
    JOURNAL OF CONTAMINANT HYDROLOGY, 2013, 152 : 35 - 43
  • [4] POROSITY MEASUREMENTS IN NATURAL POROUS ROCKS USING MAGNETIC-RESONANCE-IMAGING
    MERRILL, MR
    APPLIED MAGNETIC RESONANCE, 1993, 5 (3-4) : 307 - 321
  • [5] Electro-osmotic flow in porous media using magnetic resonance imaging
    Locke, BR
    Acton, M
    Gibbs, SJ
    LANGMUIR, 2001, 17 (22) : 6771 - 6781
  • [6] Imaging of water flow in porous media by magnetic resonance imaging microscopy
    Deurer, M
    Vogeler, I
    Khrapitchev, A
    Scotter, D
    JOURNAL OF ENVIRONMENTAL QUALITY, 2002, 31 (02) : 487 - 493
  • [7] Nuclear magnetic resonance imaging for studies of flow and transport in porous media
    Chen, Q
    Kinzelbach, W
    Oswald, S
    JOURNAL OF ENVIRONMENTAL QUALITY, 2002, 31 (02) : 477 - 486
  • [8] Magnetic resonance imaging measurements evidence weak dispersion in homogeneous porous media
    Lehoux, A. P.
    Rodts, S.
    Faure, P.
    Michel, E.
    Courtier-Murias, D.
    Coussot, P.
    PHYSICAL REVIEW E, 2016, 94 (05)
  • [9] Measurement of Gas Diffusion Coefficient in Liquid-Saturated Porous Media Using Magnetic Resonance Imaging
    Song, Yongchen
    Hao, Min
    Zhao, Yuechao
    Zhang, Liang
    RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY A, 2014, 88 (12) : 2265 - 2270
  • [10] Measurement of gas diffusion coefficient in liquid-saturated porous media using magnetic resonance imaging
    Yongchen Song
    Min Hao
    Yuechao Zhao
    Liang Zhang
    Russian Journal of Physical Chemistry A, 2014, 88 : 2265 - 2270