Sensitive electrochemical platform for trace determination of Pb2+ based on multilayer Bi-MOFs/reduced graphene oxide films modified electrode

被引:24
作者
Zou, Jin [1 ,2 ]
Zhong, Wei [2 ]
Gao, Feng [2 ]
Tu, Xiaolong [2 ]
Chen, Shangxing [1 ]
Huang, Xigen [1 ,2 ]
Wang, Xiaoqiang [2 ]
Lu, Limin [1 ,2 ]
Yu, Yongfang [2 ]
机构
[1] East China Woody Fragrance & Flavor Engn Res Ctr, JXAU, Coll Forestry, Nanchang, Jiangxi, Peoples R China
[2] Jiangxi Agr Univ, Key Lab Crop Physiol Ecol & Genet Breeding, Minist Educ, Coll Sci,Key Lab Chem Utilizat Plant Resources Na, Nanchang 330045, Jiangxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Bi-BTC; Graphene; Layer-by-layer assembly; Differential pulse anodic stripping voltammetry; Determination of Pb2+; Electrochemical sensor; ANODIC-STRIPPING VOLTAMMETRY; METAL-ORGANIC FRAMEWORKS; BISMUTH; NANOCOMPOSITES; FABRICATION; ADSORPTION; WATER;
D O I
10.1007/s00604-020-04571-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A multilayer Bi-BTC/reduced graphene oxide (Bi-BTC/rGO) (BTC, 1,3,5-benzenetricarboxylic acid) film electrode was adopted to construct a highly sensitive Pb2+ electrochemical sensor. The multilayer Bi-BTC/rGO films were prepared via alternate cast of Bi-BTC and graphene oxide (GO) on a glassy carbon electrode, followed by electro-reduction of the GO components. Bi-BTC has porous broom-like structure and its organic ligand has abundant functional groups, which are favorable for Pb(2+)adsorption and preconcentration. The introduction of rGO layer improves the conductivity of the MOFs material. Moreover, the multilayer composite structure greatly increased the exposure of active sites and the surface area of reactive contact, finally realizing the highly sensitive detection of Pb2+. Pb2+ was determined by differential pulse anodic stripping voltammetry and the response current was recorded at - 0.62 V. The [Bi-BTC/rGO](2) electrode provides a wide linear response ranging from 0.062 to 20.72 mu g/L and a low limit of detection (LOD) of 0.021 mu g/L (S/N = 3) for Pb2+, which is lower than the guideline value proposed by the World Health Organization. The method has been applied to determine Pb2+ in industrial wastewater with recoveries of 99.2-104% and RSDs of 3.4-4.0% (n = 3).
引用
收藏
页数:8
相关论文
共 33 条
  • [21] FACTORS AFFECTING THE ELECTROANALYTICAL BEHAVIOR OF POLYPYRROLE-MODIFIED ELECTRODES BEARING COMPLEXING LIGANDS
    SHIU, KK
    CHAN, OY
    PANG, SK
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (17) : 2828 - 2834
  • [22] Soylak M, 2011, J AOAC INT, V94, P978
  • [23] Electrochemical Film Deposition of the Zirconium Metal-Organic Framework UiO-66 and Application in a Miniaturized Sorbent Trap
    Stassen, Ivo
    Styles, Mark
    Van Assche, Tom
    Campagnol, Nicolo
    Fransaer, Jan
    Denayer, Joeri
    Tan, Jin-Chong
    Falcaro, Paolo
    De Vos, Dirk
    Ameloot, Rob
    [J]. CHEMISTRY OF MATERIALS, 2015, 27 (05) : 1801 - 1807
  • [24] Simultaneous determination of heavy metals by an electrochemical method based on a nanocomposite consisting of fluorinated graphene and gold nanocage
    Tan, Zhao
    Wu, Wenqin
    Feng, Chuanqi
    Wu, Huimin
    Zhang, Zhaowei
    [J]. MICROCHIMICA ACTA, 2020, 187 (07)
  • [25] The fabrication and characterization of a bismuth nanoparticle modified boron doped diamond electrode and its application to the simultaneous determination of cadmium(II) and lead(II)
    Toghill, Kathryn E.
    Wildgoose, Gregory G.
    Moshar, Amir
    Mulcahy, Chris
    Compton, Richard G.
    [J]. ELECTROANALYSIS, 2008, 20 (16) : 1731 - 1737
  • [26] A novel metal-organic framework based on bismuth and trimesic acid: synthesis, structure and properties
    Wang, Guanzhi
    Liu, Yuanyuan
    Huang, Baibiao
    Qin, Xiaoyan
    Zhang, Xiaoyang
    Dai, Ying
    [J]. DALTON TRANSACTIONS, 2015, 44 (37) : 16238 - 16241
  • [27] Bismuth/Polyaniline/Glassy Carbon Electrodes Prepared with Different Protocols for Stripping Voltammetric Determination of Trace Cd and Pb in Solutions Having Surfactants
    Wang, Z. M.
    Guo, H. W.
    Liu, E.
    Yang, G. C.
    Khun, N. W.
    [J]. ELECTROANALYSIS, 2010, 22 (02) : 209 - 215
  • [28] Highly sensitive simultaneous determination of cadmium (II), lead (II), copper (II), and mercury (II) ions on N-doped graphene modified electrode
    Xing, Huakun
    Xu, Jingkun
    Zhu, Xiaofei
    Duan, Xuemin
    Lu, Limin
    Wang, Wenmin
    Zhang, Youshan
    Yang, Taotao
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 760 : 52 - 58
  • [29] Ultrasensitive surface-enhanced Raman scattering detection in common fluids
    Yang, Shikuan
    Dai, Xianming
    Stogin, Birgitt Boschitsch
    Wong, Tak-Sing
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2016, 113 (02) : 268 - 273
  • [30] Covalent Immobilization of Cu3(btc)2 at Chitosan-Electroreduced Graphene Oxide Hybrid Film and Its Application for Simultaneous Detection of Dihydroxybenzene Isomers
    Yang, Yizhen
    Wang, Qingxiang
    Qiu, Weiwei
    Guo, Hongxu
    Gao, Feng
    [J]. JOURNAL OF PHYSICAL CHEMISTRY C, 2016, 120 (18) : 9794 - 9803