摘要
We present a high-speed complex conjugate resolved 1 mu m swept source optical coherence tomography [SS-OCT] system using coherence revival of the light source for clinical imaging of the anterior segment of the eye. High-speed of 100,000 A-scans/sec and 1 mu m imaging window of OCT permits dense 3D imaging of the anterior segment, minimizing the influence of motion artifacts and deep penetration of images for topographic analysis. The swept laser performance with internal clocking was adapted to achieve extended imaging depth requirements. The feasibility of our instrument for visualization of the anterior segment of patients with the Boston Keratoprosthesis (KPro) was discussed. The relations between of the KPro and the surrounding tissue were also demonstrated.
引用
收藏
页数:8
相关论文
共 30 条
  • [1] Phase-sensitive optical coherence tomography at up to 370,000 lines per second using buffered Fourier domain mode-locked lasers
    Adler, Desmond C.
    Huber, Robert
    Fujimoto, James G.
    [J]. OPTICS LETTERS, 2007, 32 (06) : 626 - 628
  • [2] Alzaga A. G., 2012, CLIN OPHTHALMOL, V6, P1355
  • [3] Improved spectral optical coherence tomography using optical frequency comb
    Bajraszewski, Tomasz
    Wojtkowski, Maciej
    Szkulmowski, Maciej
    Szkulmowska, Anna
    Huber, Robert
    Kowalczyk, Andrzej
    [J]. OPTICS EXPRESS, 2008, 16 (06): : 4163 - 4176
  • [4] Swept source optical coherence tomography using an all-fiber 1300-nm ring laser source
    Choma, MA
    Hsu, K
    Izatt, JA
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2005, 10 (04)
  • [5] Sensitivity advantage of swept source and Fourier domain optical coherence tomography
    Choma, MA
    Sarunic, MV
    Yang, CH
    Izatt, JA
    [J]. OPTICS EXPRESS, 2003, 11 (18): : 2183 - 2189
  • [6] Complex conjugate resolved heterodyne swept source optical coherence tomography using coherence revival
    Dhalla, Al-Hafeez
    Nankivil, Derek
    Izatt, Joseph A.
    [J]. BIOMEDICAL OPTICS EXPRESS, 2012, 3 (03): : 633 - 649
  • [7] Fabrication of a keratoprosthesis
    Doane, MG
    Dohlman, CH
    Bearse, G
    [J]. CORNEA, 1996, 15 (02) : 179 - 184
  • [8] SOME FACTORS INFLUENCING OUTCOME AFTER KERATOPROSTHESIS SURGERY
    DOHLMAN, CH
    DOANE, MG
    [J]. CORNEA, 1994, 13 (03) : 214 - 218
  • [9] Subharmonic Fourier domain mode locking
    Eigenwillig, Christoph M.
    Wieser, Wolfgang
    Biedermann, Benjamin R.
    Huber, Robert
    [J]. OPTICS LETTERS, 2009, 34 (06) : 725 - 727
  • [10] MEASUREMENT OF INTRAOCULAR DISTANCES BY BACKSCATTERING SPECTRAL INTERFEROMETRY
    FERCHER, AF
    HITZENBERGER, CK
    KAMP, G
    ELZAIAT, SY
    [J]. OPTICS COMMUNICATIONS, 1995, 117 (1-2) : 43 - 48