Validation of the ITER CXRS design by tests on TEXTOR

被引:9
作者
Jaspers, R. J. E. [2 ]
von Hellermann, M. G. [2 ]
Delabie, E. [2 ]
Biel, W. [1 ]
Marchuk, O. [1 ]
Yao, L. [3 ]
机构
[1] EURATOM FZJ, Forschungszentrum Julich, D-52428 Julich, Germany
[2] TEC, NL-3430 BE Nieuwegein, Netherlands
[3] Univ Elect Sci & Technol China, Sch Phys Elect, Chengdu 610054, Peoples R China
关键词
plasma diagnostics; plasma temperature; Tokamak devices;
D O I
10.1063/1.2979874
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The charge exchange recombination spectroscopy system (CXRS) for ITER is designed to measure the core helium concentration, and in addition, profiles of ion temperature and rotation. This highly demanding task, due to the huge background radiation (bremsstrahlung) and the high attenuation of the dedicated diagnostic neutral beam, requires high throughput spectrometers with high resolution. On TEXTOR, a CXRS system has been developed with the aim to test the physics implications of these specifications. (i) A relevant spectrometer has been tested. (ii) A method to determine the helium concentrations from the CXRS intensity, using the beam emission has been evaluated. A 20% discrepancy in beam emission was revealed. (iii) The determination of the magnetic pitch angle by the ratio of Balmer lines showed qualitatively the right behavior, although the accuracy was limited by the polarization sensitivity of the first mirror. (iv) The simulation code developed for the prediction of the CXRS spectra was quantitatively confronted with experimental data.
引用
收藏
页数:4
相关论文
共 9 条
[1]  
BIEL W, 2008, P IAEA INT WOR UNPUB, V1
[2]   AN OVERVIEW OF CHARGE-EXCHANGE SPECTROSCOPY AS A PLASMA DIAGNOSTIC [J].
ISLER, RC .
PLASMA PHYSICS AND CONTROLLED FUSION, 1994, 36 (02) :171-208
[3]   Using Cramer-Rao theory as spectrometer design tool aimed at quantitative complex-spectrum analysis [J].
Klinkhamer, J. F. F. ;
van der Valk, N. C. J. ;
von Hellermann, M. G. ;
Jaspers, R. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (10)
[4]   The motional Stark effect: Overview and future development (invited) [J].
Levinton, FM .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (01) :810-814
[5]   BEAM EMISSION-SPECTROSCOPY AS A COMPREHENSIVE PLASMA DIAGNOSTIC-TOOL [J].
MANDL, W ;
WOLF, RC ;
VONHELLERMANN, MG ;
SUMMERS, HP .
PLASMA PHYSICS AND CONTROLLED FUSION, 1993, 35 (10) :1373-1394
[6]   Review of atomic data needs for active charge-exchange spectroscopy on ITER [J].
Marchuk, O. ;
Bertschinger, G. ;
Biel, W. ;
Delabie, E. ;
von Hellermann, M. G. ;
Jaspers, R. ;
Reiter, D. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (10)
[7]   Status of the DNB based ITER CXRS and BES diagnostic [J].
von Hellermann, M. ;
Jaspers, R. ;
Biel, W. ;
Litnovsky, A. ;
Neubauer, O. ;
Pap, M. ;
Hawkes, N. C. ;
Marren, C. ;
Walton, B. ;
Kaschuck, Y. ;
Serov, V. ;
Tugarinov, S. ;
Vliegenthart, W. ;
Moddemeijer, K. ;
Walker, C. ;
Ingesson, C. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (10)
[8]  
von Hellermann MG, 2008, AIP CONF PROC, V988, P165
[9]   Modeling the effect of reflection from metallic walls on spectroscopic measurements [J].
Zastrow, K. -D. ;
Keatings, S. R. ;
Marot, L. ;
O'Mullane, M. G. ;
de Temmerman, G. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (10)