Semi-automated alignment and quantification of peaks using parallel factor analysis for comprehensive two-dimensional liquid chromatography-diode array detector data sets

被引:17
作者
Allen, Robert C. [1 ]
Rutan, Sarah C. [1 ]
机构
[1] Virginia Commonwealth Univ, Richmond, VA 23284 USA
基金
美国国家科学基金会;
关键词
Comprehensive two-dimensional liquid chromatography; Diode array detector; Four-way data; Chromatographic alignment; Parallel factor analysis; ALTERNATING LEAST-SQUARES; RETENTION TIME ALIGNMENT; CHEMOMETRIC ANALYSIS; WARPING ALGORITHM; COMPONENTS; RESOLUTION; SELECTION; PARAFAC2;
D O I
10.1016/j.aca.2012.02.019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Parallel factor analysis was used to quantify the relative concentrations of peaks within four-way comprehensive two dimensional liquid chromatography-diode array detector data sets. Since parallel factor analysis requires that the retention times of peaks between each injection are reproducible, a semi-automated alignment method was developed that utilizes the spectra of the compounds to independently align the peaks without the need for a reference injection. Peak alignment is achieved by shifting the optimized chromatographic component profiles from a three-way parallel factor analysis model applied to each injection. To ensure accurate shifting, components are matched up based on their spectral signature and the position of the peak in both chromatographic dimensions. The degree of shift, for each peak, is determined by calculating the distance between the median data point of the respective dimension (in either the second or first chromatographic dimension) and the maximum data point of the peak furthest from the median. All peaks that were matched to this peak are then aligned to this common retention data point. Target analyte recoveries for four simulated data sets were within 2% of 100% recovery in all cases. Two different experimental data sets were also evaluated. Precision of quantification of two spectrally similar and partially coeluting peaks present in urine was as good as or better than 4%. Good results were also obtained for a challenging analysis of phenytoin in waste water effluent, where the results of the semi-automated alignment method agreed with the reference LC-LC MS/MS method within the precision of the methods. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:7 / 17
页数:11
相关论文
共 44 条
[11]  
2-Y
[12]   Assessment of new constraints applied to the alternating least squares method [J].
deJuan, A ;
VanderHeyden, Y ;
Tauler, R ;
Massart, DL .
ANALYTICA CHIMICA ACTA, 1997, 346 (03) :307-318
[13]   Parametric time warping [J].
Eilers, PHC .
ANALYTICAL CHEMISTRY, 2004, 76 (02) :404-411
[14]   A perfect smoother [J].
Eilers, PHC .
ANALYTICAL CHEMISTRY, 2003, 75 (14) :3631-3636
[15]   Objective data alignment and chemometric analysis of comprehensive two-dimensional separations with run-to-run peak shifting on both dimensions [J].
Fraga, CG ;
Prazen, BJ ;
Synovec, RE .
ANALYTICAL CHEMISTRY, 2001, 73 (24) :5833-5840
[16]   The chemometric resolution and quantification of overlapped peaks form comprehensive two-dimensional liquid chromatography [J].
Fraga, CG ;
Corley, CA .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1096 (1-2) :40-49
[17]   Selective comprehensive multidimensional separation for resolution enhancement in high performance liquid chromatography. Part II: Applications [J].
Groskreutz, Stephen R. ;
Swenson, Michael M. ;
Secor, Laura B. ;
Stoll, Dwight R. .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1228 :41-50
[18]   Selective comprehensive multi-dimensional separation for resolution enhancement in high performance liquid chromatography. Part I: Principles and instrumentation [J].
Groskreutz, Stephen R. ;
Swenson, Michael M. ;
Secor, Laura B. ;
Stoll, Dwight R. .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1228 :31-40
[19]   High-speed peak matching algorithm for retention time alignment of gas chromatographic data for chemometric analysis [J].
Johnson, KJ ;
Wright, BW ;
Jarman, KH ;
Synovec, RE .
JOURNAL OF CHROMATOGRAPHY A, 2003, 996 (1-2) :141-155
[20]  
Kiers HAL, 1999, J CHEMOMETR, V13, P275, DOI 10.1002/(SICI)1099-128X(199905/08)13:3/4<275::AID-CEM543>3.0.CO