Semi-automated alignment and quantification of peaks using parallel factor analysis for comprehensive two-dimensional liquid chromatography-diode array detector data sets

被引:17
作者
Allen, Robert C. [1 ]
Rutan, Sarah C. [1 ]
机构
[1] Virginia Commonwealth Univ, Richmond, VA 23284 USA
基金
美国国家科学基金会;
关键词
Comprehensive two-dimensional liquid chromatography; Diode array detector; Four-way data; Chromatographic alignment; Parallel factor analysis; ALTERNATING LEAST-SQUARES; RETENTION TIME ALIGNMENT; CHEMOMETRIC ANALYSIS; WARPING ALGORITHM; COMPONENTS; RESOLUTION; SELECTION; PARAFAC2;
D O I
10.1016/j.aca.2012.02.019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Parallel factor analysis was used to quantify the relative concentrations of peaks within four-way comprehensive two dimensional liquid chromatography-diode array detector data sets. Since parallel factor analysis requires that the retention times of peaks between each injection are reproducible, a semi-automated alignment method was developed that utilizes the spectra of the compounds to independently align the peaks without the need for a reference injection. Peak alignment is achieved by shifting the optimized chromatographic component profiles from a three-way parallel factor analysis model applied to each injection. To ensure accurate shifting, components are matched up based on their spectral signature and the position of the peak in both chromatographic dimensions. The degree of shift, for each peak, is determined by calculating the distance between the median data point of the respective dimension (in either the second or first chromatographic dimension) and the maximum data point of the peak furthest from the median. All peaks that were matched to this peak are then aligned to this common retention data point. Target analyte recoveries for four simulated data sets were within 2% of 100% recovery in all cases. Two different experimental data sets were also evaluated. Precision of quantification of two spectrally similar and partially coeluting peaks present in urine was as good as or better than 4%. Good results were also obtained for a challenging analysis of phenytoin in waste water effluent, where the results of the semi-automated alignment method agreed with the reference LC-LC MS/MS method within the precision of the methods. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:7 / 17
页数:11
相关论文
共 44 条
[1]   Investigation of interpolation techniques for the reconstruction of the first dimension of comprehensive two-dimensional liquid chromatography-diode array detector data [J].
Allen, Robert C. ;
Rutan, Sarah C. .
ANALYTICA CHIMICA ACTA, 2011, 705 (1-2) :253-260
[2]  
Bailey H.P., 2011, J. Chromatogr. A, V1217, P4313
[3]  
Bailey H.P., J SEP SCI UNPUB
[4]   Chemometric resolution and quantification of four-way data arising from comprehensive 2D-LC-DAD analysis of human urine [J].
Bailey, Hope P. ;
Rutan, Sarah C. .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2011, 106 (01) :131-141
[5]  
Beens J, 1998, HRC-J HIGH RES CHROM, V21, P47
[6]   Analysis of three- and four-way data using multivariate curve resolution-alternating least squares with global multi-way kinetic fitting [J].
Bezemer, E ;
Rutan, SC .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2006, 81 (01) :82-93
[7]   Time-alignment of bidimensional chromatograms in the presence of uncalibrated interferences using parallel factor analysis Application to multi-component determinations using liquid-chromatography with spectrofluorimetric detection [J].
Bortolato, S. A. ;
Arancibia, J. A. ;
Escandar, G. M. ;
Olivieri, A. C. .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2010, 101 (01) :30-37
[8]   PARAFAC. Tutorial and applications [J].
Bro, R .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1997, 38 (02) :149-171
[9]   Cross-validation of component models: A critical look at current methods [J].
Bro, R. ;
Kjeldahl, K. ;
Smilde, A. K. ;
Kiers, H. A. L. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (05) :1241-1251
[10]  
Bro R, 1999, J CHEMOMETR, V13, P295, DOI 10.1002/(SICI)1099-128X(199905/08)13:3/4<295::AID-CEM547>3.0.CO