Continuous Measurement-While-Drilling Utilizing Strap-Down Multi-Model Surveying System

被引:34
|
作者
Xue Qilong [1 ,2 ]
Wang Ruihe [1 ]
Sun Feng [3 ]
Huang Leilei [4 ]
Han Laiju [3 ]
机构
[1] China Univ Petr, Coll Petr Engn, Qingdao 266555, Peoples R China
[2] Univ Calgary, Dept Elect & Comp Engn, Calgary, AB T2N 1N4, Canada
[3] Sinopec Shengli Oil Field Adm, Drilling Technol Res Inst, Dongying 257000, Peoples R China
[4] Sinopec Int Petr Serv Corp, Beijing 100011, Peoples R China
关键词
Continuous MWD; rotary steerable; spatial attitude; stick-slip vibration; strap-down;
D O I
10.1109/TIM.2013.2282412
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the oil drilling process, measurement-while-drilling system is usually used to provide real-time monitoring of the position and orientation of the bottom hole. Usually the bottom drill string attitude is measured on the condition that the drill string is static. Particularly, in rotary steerable drilling application, it is a challenging problem to accurately measure the spatial attitude (inclination, azimuth, and tool face) of the bottom drilling tool with the drill string rotating. A set of "strap-down" measurement system was developed in this paper, the triaxial accelerometer and triaxial fluxgate were installed near the bit, and real-time well deviation and azimuth can been measured. Laboratory experiments show that the dynamic solver methods will meet the project requirements. However, according to the drilling field tests, playback analysis on storage data of the underground measurement indicates that drill string vibration is the main reason for measurement errors. So, by setting a time window, the real-time measurement of the accelerometer and the flux gate signal are processed and analyzed, the movement patterns of the rotary drilling tool at the bottom were judged within the time window. Stick-slip phenomenon is utilized to improve the measurement accuracy and to reduce the impact of lateral vibration of the drilling string on the measurement system. We could take advantage of stick-slip phenomenon because of it cannot be avoided completely, although it should be avoided in order to improve the drilling string operating life. Simulation results showed that recommended dynamic survey approach could effectively enhance measurement precision, and deduce effect of vibration on resolve results.
引用
收藏
页码:650 / 657
页数:8
相关论文
共 33 条
  • [1] The calibration algorithm for installation error of the strap-down measurement-while-drilling system
    Feng, Sun
    Qilong, Xue
    Electronic Journal of Geotechnical Engineering, 2013, 18 O : 3217 - 3228
  • [2] Development of strap-down automatic vertical drilling system
    Sun, Feng
    Xue, Qilong
    Bai, Pingping
    Electronic Journal of Geotechnical Engineering, 2013, 18 Q : 3665 - 3673
  • [3] Measurement-while-drilling surveying of highly inclined and horizontal well sections utilizing single-axis gyro sensing system
    Noureldin, A
    Irvine-Halliday, D
    Mintchev, MP
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2004, 15 (12) : 2426 - 2434
  • [4] Accuracy limitations of FOG-based continuous measurement-while-drilling surveying instruments for horizontal wells
    Noureldin, A
    Irvine-Halliday, D
    Mintchev, MP
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2002, 51 (06) : 1177 - 1191
  • [5] Method to Suppress the Temperature Dependency of Scale Factor in Measurement-While-Drilling Surveying Utilizing Fiber Optic Gyroscope
    He, Changhong
    Yang, Chuanchuan
    Wang, Qin
    Xie, Jun
    Tan, Zhongwei
    Wang, Ziyu
    Wang, Xinyue
    2015 OPTO-ELECTRONICS AND COMMUNICATIONS CONFERENCE (OECC), 2015,
  • [6] The strap-down automatic vertical drilling system design and field applications
    Qilong, Xue
    Ruihe, Wang
    Leilei, Huang
    Feng, Sun
    Laiju, Han
    Electronic Journal of Geotechnical Engineering, 2012, 17 V : 3009 - 3018
  • [7] FOG-based navigation in downhole environment during horizontal drilling utilizing a complete inertial measurement unit: Directional measurement-while-drilling surveying
    Ledroz, AG
    Pecht, E
    Cramer, D
    Mintchev, MP
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2005, 54 (05) : 1997 - 2006
  • [8] Integrated Calibration of Strap-Down Geomagnetic Vector Measurement System
    Pang, Hongfeng
    Wan, Chengbiao
    Mou, Shaofeng
    Wei, Lu
    Li, Heng
    Zhang, Qi
    Pan, Mengchun
    Yang, Daoning
    IEEE SENSORS JOURNAL, 2022, 22 (11) : 10476 - 10484
  • [9] Physics-Based Observers for Measurement-While-Drilling System in Down-the-Hole Drills
    Bout, Gabriel
    Brito, Diego
    Gomez, Rene
    Carvajal, Gonzalo
    Ramirez, Guillermo
    MATHEMATICS, 2022, 10 (24)
  • [10] A new measurement-while-drilling system based on inertial technology
    Song, Hua
    Huang, Huiyin
    Zhang, Junxiang
    Qu, Di
    ADVANCES IN MECHANICAL ENGINEERING, 2018, 10 (03):