Fault diagnosis based on PCA for sensors of laboratorial wastewater treatment process

被引:50
作者
Tao, E. P. [1 ]
Shen, W. H. [1 ]
Liu, T. L. [2 ]
Chen, X. Q. [1 ]
机构
[1] S China Univ Technol, State Key Lab Pulp & Paper Engn, Guangzhou 510640, Guangdong, Peoples R China
[2] Univ British Columbia, Sch Engn, Kelowna, BC V1V 1V7, Canada
基金
中国国家自然科学基金;
关键词
Wastewater; Sensor; Fault diagnosis; Principal component analysis; STATE;
D O I
10.1016/j.chemolab.2013.07.012
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents a PCA (principal component analysis)-based diagnostic approach, combining the principal component scores with the principal component loadings, to determine the fault location of sensors in a pilot-scale SBR (sequencing batch reactor activated sludge process) wastewater treatment process. The PCA diagnostic model is firstly built with the historical normal data, and the determination of fault location of sensors in wastewater treatment process is further achieved through the combination of the scores with the loadings of principal components. The study results reveal that PCA model can be used to detect faults; the loadings of principal components can well represent the contributions of variables to the principal components; and the scores of principal components give a clear indication of the faulty samples. The feasibility and effectiveness of the application of the combination of score plots with loading plots for sensor fault diagnosis in the wastewater treatment process are well demonstrated in the study. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:49 / 55
页数:7
相关论文
共 19 条
[1]   A combined approach for a better understanding of wastewater treatment plants operation: Statistical analysis of monitoring database and sludge physico-chemical characterization [J].
Avella, A. C. ;
Goerner, T. ;
Yvon, J. ;
Chappe, P. ;
Guinot-Thomas, P. ;
de Donato, Ph .
WATER RESEARCH, 2011, 45 (03) :981-992
[2]  
Beebe K.R., 1998, CHEMOMETRICS PRACTIC
[3]   Fault detection and diagnosis based on improved PCA with JAA method in VAV systems [J].
Du, Zhimin ;
Jin, Xinqiao ;
Wu, Lizhou .
BUILDING AND ENVIRONMENT, 2007, 42 (09) :3221-3232
[4]  
Du ZM, 2009, ENERGY CONVERSION MA, V49, P3654
[5]   PARTIAL LEAST-SQUARES REGRESSION - A TUTORIAL [J].
GELADI, P ;
KOWALSKI, BR .
ANALYTICA CHIMICA ACTA, 1986, 185 :1-17
[6]   Proton exchange membrane fuel cell system diagnosis based on the multivariate statistical method [J].
Hua, Jianfeng ;
Li, Jianqiu ;
Ouyang, Minggao ;
Lu, Languang ;
Xu, Liangfei .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2011, 36 (16) :9896-9905
[7]   CONTROL PROCEDURES FOR RESIDUALS ASSOCIATED WITH PRINCIPAL COMPONENT ANALYSIS [J].
JACKSON, JE ;
MUDHOLKAR, GS .
TECHNOMETRICS, 1979, 21 (03) :341-349
[8]   STATISTICAL PROCESS-CONTROL OF MULTIVARIATE PROCESSES [J].
MACGREGOR, JF ;
KOURTI, T .
CONTROL ENGINEERING PRACTICE, 1995, 3 (03) :403-414
[9]   Identification of process operating state with operational map in municipal wastewater treatment plant [J].
Moon, T. S. ;
Kim, Y. J. ;
Kim, J. R. ;
Cha, J. H. ;
Kim, D. H. ;
Kim, C. W. .
JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2009, 90 (02) :772-778
[10]  
Peng Zhao-xu, 2011, Journal of the Harbin Institute of Technology, V43, P42