Radiation Exposure to the Surgeon During Percutaneous Endoscopic Lumbar Discectomy A Prospective Study

被引:169
作者
Ahn, Yong [1 ]
Kim, Chang-Ho [2 ]
Lee, June Ho [1 ]
Lee, Sang-Ho [1 ]
Kim, Jin-Sung [3 ]
机构
[1] Wooridul Spine Hosp, Dept Neurosurg, Seoul 135100, South Korea
[2] Wooridul Spine Hosp, Div Radiol, Seoul 135100, South Korea
[3] Catholic Univ Korea, Seoul St Marys Hosp, Dept Neurosurg, Seoul, South Korea
关键词
radiation dosage; radiation risk; fluoroscopy; percutaneous; discectomy; PEDICLE SCREW INSERTION; SURGICAL TECHNIQUE; IONIZING-RADIATION; STAFF DOSIMETRY; DISC HERNIATION; VERTEBROPLASTY; PATIENT; CANCER; FLUOROSCOPY; REDUCTION;
D O I
10.1097/BRS.0b013e318275ca58
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A prospective study. Objective. The purpose of this study was to determine the radiation dose to which the surgeons are exposed during percutaneous endoscopic lumbar discectomy (PELD) and to calculate the allowable number of cases per year. Summary of Background Data. Transforaminal PELD is a minimally invasive technique for soft disc herniation. Minimal invasiveness can be achieved through the use of fluoroscopy and endoscopy. The radiation dose to the surgeon during PELD is unknown. Methods. The occupational radiation dose absorbed by 3 spinal surgeons performing 30 consecutive PELDs (33 levels) during a 3-month period was evaluated. Transforaminal PELDs were performed according to the standard technique. The radiation exposure of the neck, chest, arm, and both hands of the surgeons was measured. Occupational exposure guidelines of National Council on Radiation Protection & Measurements were used to calculate the allowable number of procedures per year. Results. The mean operation time was 49.8 minutes, and the mean fluoroscopy time was 2.5 minutes. No significant correlations were found between operation time and fluoroscopy time. The calculated radiation doses per operated level were as follows: neck, 0.0785 mSv; chest, 0.1718 mSv; right upper arm, 0.0461 mSv; left ring finger, 0.7318 mSv; and right ring finger, 0.6694 mSv. The protective effects of a lead collar and lead apron were demonstrated by the reduction of the radiation dose by 96.9% and 94.2%, respectively. Therefore, with regard to whole-body radiation, 5379 operations can be performed per year using a lead apron, whereas only 291 operations can be performed without using a lead apron. Moreover, 1910 operations can be performed within the occupational exposure limit for the eyes (150 mSv), and 683 operations can be performed within the occupational exposure limit for the hands (500 mSv). Conclusion. Without radiation shielding, a surgeon performing 291 PELDs annually would be exposed to the maximum allowable radiation dose. Given the measurable lifetime radiation hazards to the surgeon, the use of adequate protective equipment is essential to reducing exposure during PELD.
引用
收藏
页码:617 / 625
页数:9
相关论文
共 47 条
[1]   EFFECTIVENESS OF GLASS LENSES IN REDUCING EXPOSURE TO EYES [J].
AGARWAL, SK ;
FRIESEN, EJ ;
HUDDLESTON, AL ;
RAO, RP .
RADIOLOGY, 1978, 129 (03) :810-811
[2]   Percutaneous endoscopic lumbar discectomy for recurrent disc herniation: Surgical technique, outcome, and prognostic factors of 43 consecutive cases [J].
Ahn, Y ;
Lee, SH ;
Park, WM ;
Lee, HY ;
Shin, SW ;
Kang, HY .
SPINE, 2004, 29 (16) :E326-E332
[3]   100 years of observation on British radiologists: mortality from cancer and other causes 1897-1997 [J].
Berrington, A ;
Darby, SC ;
Weiss, HA ;
Doll, R .
BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (882) :507-519
[4]   Surgeon and patient radiation exposure in minimally invasive transforaminal lumbar interbody fusion [J].
Bindal, Rajesh K. ;
Glaze, Sharon ;
Ognoskie, Meghann ;
Tunner, Van ;
Malone, Robert ;
Ghosh, Subrata .
JOURNAL OF NEUROSURGERY-SPINE, 2008, 9 (06) :570-573
[5]   CANCER STATISTICS, 1991 [J].
BORING, CC ;
SQUIRES, TS ;
TONG, T .
CA-A CANCER JOURNAL FOR CLINICIANS, 1991, 41 (01) :19-36
[6]   Cancer risks attributable to low doses of ionizing radiation: Assessing what we really know [J].
Brenner, DJ ;
Doll, R ;
Goodhead, DT ;
Hall, EJ ;
Land, CE ;
Little, JB ;
Lubin, JH ;
Preston, DL ;
Preston, RJ ;
Puskin, JS ;
Ron, E ;
Sachs, RK ;
Samet, JM ;
Setlow, RB ;
Zaider, M .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (24) :13761-13766
[7]   Benefits and safety of CT fluoroscopy in interventional radiologic procedures [J].
Carlson, SK ;
Bender, CE ;
Classic, KL ;
Zink, FE ;
Quam, JP ;
Ward, EM ;
Oberg, AL .
RADIOLOGY, 2001, 219 (02) :515-520
[8]   Mortality of doctors in different specialties: Findings from a cohort of 20000 NHS hospital consultants [J].
Carpenter, LM ;
Swerdlow, AJ ;
Fear, NT .
OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1997, 54 (06) :388-395
[9]   Risk of cataract after exposure to low doses of ionizing radiation: A 20-year prospective cohort study among US radiologic technologists [J].
Chodick, Gabriel ;
Bekiroglu, Nural ;
Hauptmann, Michael ;
Alexander, Bruce H. ;
Freedman, D. Michal ;
Doody, Michele Morin ;
Cheung, Li C. ;
Simon, Steven L. ;
Weinstock, Robert M. ;
Bouville, Andre ;
Sigurdson, Alice J. .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 2008, 168 (06) :620-631
[10]   Evaluation of thyroid shields for reduction of radiation exposure to orthopaedic surgeons [J].
Dewey, P ;
Incoll, I .
AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1998, 68 (09) :635-636