Novel electrochemical DNA biosensor based on edge-plane pyrolytic graphite for DNA interaction studies

被引:0
作者
Augustin, Michal [1 ]
Vyskocil, Vlastimil [1 ]
机构
[1] Charles Univ Prague, Fac Sci, Dept Analyt Chem, UNESCO Lab Environm Electrochem, Hlavova 8, Prague 12843 2, Czech Republic
来源
PROCEEDINGS OF THE 15TH INTERNATIONAL STUDENTS CONFERENCE MODERN ANALYTICAL CHEMISTRY | 2019年
关键词
biosensor; DNA; graphite; voltammetry; VOLTAMMETRIC DETERMINATION;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Carbon electrodes represent the most popular working electrodes used in electrochemical analysis of nucleic acids. Since the end of the 20th century, they have been frequently used for a lot of various applications in the field of electrochemical analysis of DNA, RNA, as well as synthetic mimics of nucleic acids such as PNA. Some of their remarkable properties enhanced their utilization as electrochemical transducers of sensors for DNA hybridization, DNA-drug interactions, or even monitoring DNA damage. The aim of the proposed study is the preparation, development, and subsequent testing of new electrochemical DNA biosensors based on relatively new type of carbon material "edge-plane" pyrolytic graphite (EPPG) and its subsequent utilization as a useful analytical tool.
引用
收藏
页码:263 / 268
页数:6
相关论文
共 9 条
[1]   New electrodes for old: from carbon nanotubes to edge plane pyrolytic graphite [J].
Banks, CE ;
Compton, RG .
ANALYST, 2006, 131 (01) :15-21
[2]   ELECTROCHEMICAL BEHAVIOR OF NATURAL AND BIOSYNTHETIC POLYNUCLEOTIDES AT PYROLYTIC-GRAPHITE ELECTRODE A NEW PROBE FOR STUDIES OF POLYNUCLEOTIDE STRUCTURE AND REACTIONS [J].
BRABEC, V ;
DRYHURST, G .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1978, 89 (01) :161-173
[3]   Applications of a DNA-electrochemical biosensor [J].
Diculescu, Victor Constantin ;
Chiorcea-Paquim, Ana-Maria ;
Oliveira-Brett, Ana Maria .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2016, 79 :23-36
[4]   Electrochemical DNA biosensor for detection of DNA damage induced by hydroxyl radicals [J].
Hajkova, Andrea ;
Barek, Jiri ;
Vyskocil, Vlastimil .
BIOELECTROCHEMISTRY, 2017, 116 :1-9
[5]   Voltammetric Determination of 2-Aminofluoren-9-one and Investigation of Its Interaction with DNA on a Glassy Carbon Electrode [J].
Hajkova, Andrea ;
Barek, Jiri ;
Vyskocil, Vlastimil .
ELECTROANALYSIS, 2015, 27 (01) :101-110
[6]   NOVEL ELECTROCHEMICAL SENSORS FOR CLINICAL ANALYSIS [J].
LOWE, CR ;
GOLDFINCH, MJ .
BIOCHEMICAL SOCIETY TRANSACTIONS, 1983, 11 (04) :448-451
[7]   Electrochemical biosensors for DNA hybridization and DNA damage [J].
Palecek, E ;
Fojta, M ;
Tomschik, M ;
Wang, J .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (06) :621-628
[8]   Highly sensitive voltammetric determination of lamotrigine at highly oriented pyrolytic graphite electrode [J].
Saberi, Reyhaneh-Sadat ;
Shahrokhian, Saeed .
BIOELECTROCHEMISTRY, 2012, 84 :38-43
[9]   Adsorption and detection of peptide nucleic acids at carbon paste electrodes [J].
Wang, J ;
Rivas, G ;
Cai, XH ;
Chicharro, M ;
Dontha, N ;
Luo, DB ;
Palecek, E ;
Nielsen, PE .
ELECTROANALYSIS, 1997, 9 (02) :120-124