Gadobenate dimeglumine (Multi Hance) in MR angiography: an in-vitro phantom comparison with gadopentetate dimeglumine (Magnevist) at different concentrations

被引:8
作者
Johansson, Lars [1 ]
Kirchin, Miles A. [2 ]
Ahlstrom, Hakan [1 ]
机构
[1] Univ Uppsala Hosp, Dept Radiol, Uppsala, Sweden
[2] Bracco Imaging SpA, Worldwide Med & Regulatory Affairs, Milan, Italy
关键词
Vascular; MR angiography; contrast agents - intravenous; MAGNETIC-RESONANCE ANGIOGRAPHY; PERIPHERAL ARTERIAL-DISEASE; PHYSICOCHEMICAL PROPERTIES; CONTRAST ENHANCEMENT; DIAGNOSTIC-ACCURACY; LESION DETECTION; BRAIN-TUMORS; DOUBLE-BLIND; MULTICENTER; GADOBUTROL;
D O I
10.1258/ar.2012.120181
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Numerous clinical studies suggest that gadobenate dimeglumine is diagnostically superior to other gadolinium chelates for MR imaging applications, including contrast-enhanced MR angiography (CE-MRA). However, confirmatory in-vitro phantom studies have thus far been lacking. Purpose: To evaluate the difference in signal intensity achieved with the high-relaxivity MR contrast agent gadobenate dimeglumine (MultiHance) relative to that achieved with the standard-relaxivity non-specific agent gadopentetate dimeglumine (Magnevist) at different concentrations using an in-vitro phantom study design. Material and Methods: Test tubes with whole human blood were prepared with concentrations of gadobenate dimeglumine or gadopentetate dimeglumine ranging from 0 to 12 mM. A three-dimensional (3D) T1-weighted gradient echo sequence normally used for CE-MRA of the renal arteries was performed at flip angles of 25 degrees and 35 degrees. The signal-to-noise ratio (SNR) was calculated for all concentrations of both contrast agents. Furthermore a Look-Locker sequence was used and quantitative T1 mapping was performed for all the test tubes. The contrast agent concentration in the aorta was simulated using previously published data on T1 in the aorta during the first pass of a contrast agent. The differences between gadobenate dimeglumine and gadopentetate dimeglumine were compared at the simulated concentrations. Results: The SNR achieved with gadobenate dimeglumine was consistently greater than that achieved with gadopentetate dimeglumine at all concentrations. An improvement of 15-25% in SNR was obtained when increasing the flip angle from 25 degrees to 35 degrees. The relative improvement in SNR with gadobenate dimeglumine relative to gadopentetate dimeglumine ranged from 25-72% and was markedly greater at lower concentrations with a flip angle of 35 degrees. Conclusion: Our findings suggest that the relative benefit of gadobenate dimeglumine over gadopentetate dimeglunnine for CE-MRA applications is greater at lower concentrations.
引用
收藏
页码:1112 / 1117
页数:6
相关论文
共 42 条
[1]   Prospective Comparison of Image Quality and Diagnostic Accuracy of 0.5 Molar Gadobenate Dimeglumine and 1.0 Molar Gadobutrol in Contrast-Enhanced Run-Off Magnetic Resonance Angiography of the Lower Extremities [J].
Achenbach, Marina ;
Figiel, Jens H. ;
Burbelko, Mykhaylo ;
Heverhagen, Johannes T. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 32 (05) :1166-1171
[2]   First-Pass and High-Resolution Steady-State Magnetic Resonance Angiography of the Peripheral Arteries With Gadobenate Dimeglumine An Assessment of Feasibility and Diagnostic Performance [J].
Anzidei, Michele ;
Napoli, Alessandro ;
Zaccagna, Fulvio ;
Marincola, Beatrice Cavallo ;
Zini, Chiara ;
Kirchin, Miles A. ;
Catalano, Carlo ;
Passariello, Roberto .
INVESTIGATIVE RADIOLOGY, 2011, 46 (05) :307-316
[3]   High-Resolution Steady State Magnetic Resonance Angiography of the Carotid Arteries: Are Intravascular Agents Necessary? Feasibility and Preliminary Experience With Gadobenate Dimeglumine [J].
Anzidei, Michele ;
Napoli, Alessandro ;
Marincola, Beatrice Cavallo ;
Kirchin, Miles A. ;
Neira, Cristina ;
Geiger, Daniel ;
Zaccagna, Fulvio ;
Catalano, Carlo ;
Passariello, Roberto .
INVESTIGATIVE RADIOLOGY, 2009, 44 (12) :784-792
[4]   Low-dose gadobenate dimeglumine versus standard-dose gadopentate dimeglumine for delayed contrast-enhanced cardiac magnetic resonance imaging [J].
Balci, NC ;
Inan, N ;
Anik, Y ;
Erturk, MS ;
Ural, D ;
Demirci, A .
ACADEMIC RADIOLOGY, 2006, 13 (07) :833-839
[5]   Low Dose Gadobenate Dimeglumine for Imaging Of Chronic Myocardial Infarction in Comparison With Standard Dose Gadopentetate Dimeglumine [J].
Bauner, Kerstin U. ;
Reiser, Maximilian F. ;
Huber, Armin M. .
INVESTIGATIVE RADIOLOGY, 2009, 44 (02) :95-104
[6]   A serial dilution study of gadolinium-based MR imaging contrast agents [J].
Bleicher, A. G. ;
Kanal, E. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (04) :668-673
[7]   Intra-individual crossover comparison of gadobenate dimeglumine and gadopentetate dimeglumine for contrast-enhanced magnetic resonance angiography of the supraaortic vessels at 3 Tesla [J].
Bueltmann, Eva ;
Erb, Gunter ;
Kirchin, Miles A. ;
Klose, Uwe ;
Naegele, Thomas .
INVESTIGATIVE RADIOLOGY, 2008, 43 (10) :695-702
[8]   Gadolinium chelates with weak binding to serum proteins - A new class of high-efficiency, general purpose contrast agents for magnetic resonance imaging [J].
Cavagna, FM ;
Maggioni, F ;
Castelli, PM ;
Dapra, M ;
Imperatori, LG ;
Lorusso, V ;
Jenkins, BG .
INVESTIGATIVE RADIOLOGY, 1997, 32 (12) :780-796
[9]   Carotid Artery Stenosis: Accuracy of Noninvasive Tests-Individual Patient Data Meta-Analysis [J].
Chappell, Francesca M. ;
Wardlaw, Joanna M. ;
Young, Gavin R. ;
Gillard, Jonathan H. ;
Roditi, Giles H. ;
Yip, Brigitte ;
Pell, Jill P. ;
Rothwell, Peter M. ;
Brown, Martin M. ;
Gough, Michael J. ;
Randall, Marc S. .
RADIOLOGY, 2009, 251 (02) :493-502
[10]   Duplex ultrasonography, magnetic resonance angiography, and computed tomography angiography for diagnosis and assessment of symptomatic, lower limb peripheral arterial disease:: systematic review [J].
Collins, Ros ;
Burch, Jane ;
Cranny, Gillian ;
Aguiar-Ibanez, Raquel ;
Craig, Dawn ;
Wright, Kath ;
Berry, Elizabeth ;
Gough, Michael ;
Kleijnen, Jos ;
Westwood, Marie .
BMJ-BRITISH MEDICAL JOURNAL, 2007, 334 (7606) :1257-1261