Surface modification of Ti 13Nb 13Zr by plasma electrolytic oxidation

被引:42
作者
Lederer, S. [1 ]
Lutz, P. [1 ]
Fuerbeth, W. [1 ]
机构
[1] DECHEMA Forschungsinst, Theodor Heuss Allee 25, D-60486 Frankfurt, Germany
关键词
Plasma electrolytic oxidation; Micro-arc oxidation; Ti; 13Nb; 13Zr; Titania; Zirconia nanoparticles; Wear resistance; IMPROVING CORROSION-RESISTANCE; TI-13NB-13ZR ALLOY; ANODIC-OXIDATION; TITANIUM-ALLOYS; OXIDE-FILM; CP-TI; COATINGS; BEHAVIOR; ALUMINUM; PEO;
D O I
10.1016/j.surfcoat.2017.12.022
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Titania coatings were produced on Ti 13Zr 13Nb by a unipolar pulsed DC plasma electrolytic oxidation (PEO) process in an electrolyte containing 1 M H2SO4 + 0.1 M H3PO4. The samples were galvanostatically anodized under a constant charge-carrier density of 63 C cm(-2) and current-densities reaching from 14 mA cm(-2) up to 700 mA cm(-2). Both a constant current mode and a unipolar pulsed mode with a duty-cycle of 50% and frequencies of 1 Hz to 50 Hz were performed. The surface layers were characterized by scanning electron microscopy (SEM/EDX), X-ray diffraction (XRD) and nanoindentation. Titanium oxide coatings with a thickness of several micrometers and a porous structure could be generated. The coatings morphology was evaluated. It can be shown that the porosity can be reduced with increasing frequency. The coatings consist of anatase and rutile, the phase composition of the coatings can be adjusted by the PEO current density. The corrosion resistance of the layers was tested in a simulated body fluid (SBF) with the addition of 0.1 M H2O2 by open circuit potential measurements, potentiodynamic polarization and electrochemical impedance spectroscopy (EIS). EIS data fitting indicates a composed layer structure of an outer porous layer and an inner barrier layer. Higher current densities during the PEO process formed thicker coatings, which consequently resulted in lower corrosion currents. The addition of zirconia nanoparticles into the electrolyte increased the surface hardness to an average value of 12.8 GPa, compared to that of an untreated sample (4.1 GPa) and PEO samples without particle addition (8.5 GPa).
引用
收藏
页码:62 / 71
页数:10
相关论文
共 47 条
[1]   Plasma electrolytic oxidation of titanium in a phosphate/silicate electrolyte and tribological performance of the coatings [J].
Aliasghari, S. ;
Skeldon, P. ;
Thompson, G. E. .
APPLIED SURFACE SCIENCE, 2014, 316 :463-476
[2]   The electrochemical behaviour of Ti-13Nb-13Zr alloy in various solutions [J].
Assis, S. L. ;
Wolynec, S. ;
Costa, I. .
MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2008, 59 (09) :739-743
[3]   Effect of silver on burn wound infection control and healing: Review of the literature [J].
Atiyeh, Bishara S. ;
Costagliola, Michel ;
Hayek, Shady N. ;
Dibo, Saad A. .
BURNS, 2007, 33 (02) :139-148
[4]   Comparative study on the corrosion behavior of Ti-Nb and TMA alloys for dental application in various artificial solutions [J].
Bai, Y. J. ;
Wang, Y. B. ;
Cheng, Y. ;
Deng, F. ;
Zheng, Y. F. ;
Wei, S. C. .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2011, 31 (03) :702-711
[5]   Anatase coating on NiTi via a low-temperature sol-gel route for improving corrosion resistance [J].
Cheng, FT ;
Shi, P ;
Man, HC .
SCRIPTA MATERIALIA, 2004, 51 (11) :1041-1045
[6]   Correlation between plasma electrolytic oxidation treatment stages and coating microstructure on aluminum under unipolar pulsed DC mode [J].
Dehnavi, Vahid ;
Luan, Ben Li ;
Liu, Xing Yang ;
Shoesmith, David W. ;
Rohani, Sohrab .
SURFACE & COATINGS TECHNOLOGY, 2015, 269 :91-99
[7]   Effect of anodic oxidation parameters on the titanium oxides formation [J].
Diamanti, M. V. ;
Pedeferri, M. P. .
CORROSION SCIENCE, 2007, 49 (02) :939-948
[8]   Mechanical properties of monoclinic zirconia [J].
Eichler, J ;
Eisele, U ;
Rödel, J .
JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 2004, 87 (07) :1401-1403
[9]   Formation of grooved and porous coatings on titanium by plasma electrolytic oxidation in H2SO4/H3PO4 electrolytes and effects of coating morphology on adhesive bonding [J].
Galvis, O. A. ;
Quintero, D. ;
Castano, J. G. ;
Liu, H. ;
Thompson, G. E. ;
Skeldon, P. ;
Echeverria, F. .
SURFACE & COATINGS TECHNOLOGY, 2015, 269 :238-249
[10]   Study of the corrosion behavior of titanium and some of its alloys for biomedical and dental implant applications [J].
González, JEG ;
Mirza-Rosca, JC .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 471 (02) :109-115