Critical evaluation of the use of total reflection X-ray fluorescence spectrometry for the analysis of whole blood samples: application to patients with thyroid gland diseases

被引:15
作者
Margui, Eva [1 ]
Jablan, Jasna [2 ]
Geric, Marko [3 ]
Inic, Suzana [2 ]
Domijan, Ana-Marija [4 ]
Janusic, Renato [5 ]
Sarcevic, Bozena [5 ]
Queralt, Ignasi [6 ]
Garaj-Vrhovac, Verica [3 ]
机构
[1] Univ Girona, Dept Chem, C-M Aurelia Campmany 69, Girona 17003, Spain
[2] Univ Zagreb, Dept Analyt Chem, Fac Pharm & Biochem, A Kovacica 1, Zagreb 10000, Croatia
[3] Inst Med Res & Occupat Hlth, Ksaverska Cesta 2, Zagreb 10000, Croatia
[4] Univ Zagreb, Dept Pharmaceut Bot, Fac Pharm & Biochem, Schrottova 39, Zagreb 10000, Croatia
[5] Univ Hosp Tumours, Dept Head & Neck Surg, Ilica 197, Zagreb 10000, Croatia
[6] CSIC, Inst Environm Assessment & Water Res, IDAEA, Jordi Girona 18-26, ES-08034 Barcelona, Spain
关键词
Whole blood; Multielement analysis; TXRF; Thyroid; TRACE-ELEMENTS; ICP-MS; MULTIELEMENT DETERMINATION; TXRF; PLASMA; CANCER; TISSUE; SERUM; CADMIUM;
D O I
10.1007/s00216-019-01618-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Multielemental analysis of whole blood can provide significant information for the evaluation of nutritional status and diagnosis of certain diseases as well as for the assessment of exposure to potentially toxic metals. However, the quantification of multiple elements in whole blood is not easy partly because of the wide variation in element concentrations (from ngL(-1) to gL(-1)) and the complex matrix. The aim of this work was to develop a fast, sustainable, and reliable analytical method, in combination with low-power TXRF, for multielemental analysis of blood samples. Firstly, a set of experiments were carried out to select the best diluent type and dilution factor using the control material SeronormTM Trace Elements Whole Blood L-1. A critical evaluation of the parameters affecting the sample deposition on the reflector was also carried out including a study of the shape and element distribution of the deposited residue on the reflector by micro X-ray fluorescence spectrometry. Using the best analytical conditions, limits of detection estimated were in the low milligrams per kilogram range and similar to those obtained using more complex sample treatments such as digestion. Accuracy and precision of the results were in most cases acceptable (recoveries 89-102%, RSD 6-8%, n=5). Only underestimated values were obtained for light elements such as potassium. To prove the applicability of the method, several blood samples from control and thyroid disease patients were analyzed. Despite the fact that more samples need to be analyzed, it seems that Zn and Br contents in some of the patients are significantly higher compared to control samples.
引用
收藏
页码:1659 / 1670
页数:12
相关论文
共 39 条
  • [1] Changes in the Serum Levels of Trace Elements Before and After the Operation in Thyroid Cancer Patients
    Baltaci, Abdulkerim Kasim
    Dundar, Tugrul Kadir
    Aksoy, Faruk
    Mogulkoc, Rasim
    [J]. BIOLOGICAL TRACE ELEMENT RESEARCH, 2017, 175 (01) : 57 - 64
  • [2] Determination of trace elements in biological samples by inductively coupled plasma mass spectrometry with tetramethylammonium hydroxide solubilization at room temperature
    Batista, Bruno Lemos
    Grotto, Denise
    Rodrigues, Jairo Lisboa
    de Oliveira Souza, Vanessa Cristina
    Barbosa, Fernando, Jr.
    [J]. ANALYTICA CHIMICA ACTA, 2009, 646 (1-2) : 23 - 29
  • [3] Potential of Methyl Fluoride as a Universal Reaction Gas to Overcome Spectral Interference in the Determination of Ultratrace Concentrations of Metals in Biofluids Using Inductively Coupled Plasma-Tandem Mass Spectrometry
    Bolea-Fernandez, Eduardo
    Balcaen, Lieve
    Resano, Martin
    Vanhaecke, Frank
    [J]. ANALYTICAL CHEMISTRY, 2014, 86 (15) : 7969 - 7977
  • [4] Analysis of whole blood by ICP-MS equipped with a high temperature total sample consumption system
    Canabate, Agueda
    Garcia-Ruiz, Esperanza
    Resano, Martin
    Todoli, Jose-Luis
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (01) : 78 - 87
  • [5] Some Elements in Thyroid Tissue are Associated with More Advanced Stage of Thyroid Cancer in Korean Women
    Chung, Hye-Kyung
    Nam, Ji Sun
    Ahn, Chul Woo
    Lee, Yong Sang
    Kim, Kyung Rae
    [J]. BIOLOGICAL TRACE ELEMENT RESEARCH, 2016, 171 (01) : 54 - 62
  • [6] Highly sensitive measurement of whole blood chromium by inductively coupled plasma mass spectrometry
    Cieslak, Wendy
    Pap, Kathleen
    Bunch, Dustin R.
    Reineks, Edmunds
    Jackson, Raymond
    Le, Roxanne Stein
    Wang, Sihe
    [J]. CLINICAL BIOCHEMISTRY, 2013, 46 (03) : 266 - 270
  • [7] Multi-element analysis of vegetal foodstuff by means of low power total reflection X-ray fluorescence (TXRF) spectrometry
    Dalipi, Rogerta
    Margui, Eva
    Borgese, Laura
    Depero, Laura E.
    [J]. FOOD CHEMISTRY, 2017, 218 : 348 - 355
  • [8] Analytical performance of benchtop total reflection X-ray fluorescence instrumentation for multielemental analysis of wine samples
    Dalipi, Rogerta
    Margui, Eva
    Borgese, Laura
    Bilo, Fabjola
    Depero, Laura E.
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2016, 120 : 37 - 43
  • [9] Increased lipid peroxidation and impaired enzymatic antioxidant defense mechanism in thyroid tissue with multinodular goiter and papillary carcinoma
    Erdamar, Huesamettin
    Cimen, Behzat
    Gulcemal, Harun
    Saraymen, Recep
    Yerer, Betuel
    Demirci, Hueseyin
    [J]. CLINICAL BIOCHEMISTRY, 2010, 43 (7-8) : 650 - 654
  • [10] Bromine and bromide content in soils: Analytical approach from total reflection X-ray fluorescence spectrometry
    Gallardo, Helena
    Queralt, Ignasi
    Tapias, Josefina
    Candela, Lucila
    Margui, Eva
    [J]. CHEMOSPHERE, 2016, 156 : 294 - 301