Virtual Unenhanced Images of the Abdomen With Second-Generation Dual-Source Dual-Energy Computed Tomography Image Quality and Liver Lesion Detection

被引:67
作者
De Cecco, Carlo Nicola [1 ]
Darnell, Anna [2 ]
Macias, Napoleon [2 ]
Ramon Ayuso, Juan [2 ]
Rodriguez, Sonia [2 ]
Rimola, Jordi [2 ]
Pages, Mario [2 ]
Garcia-Criado, Angeles [2 ]
Rengo, Marco [1 ]
Laghi, Andrea [1 ]
Ayuso, Carmen [2 ]
机构
[1] Univ Roma La Sapienza, Dept Radiol Sci Oncol & Pathol, I-01400 Latina, Italy
[2] Univ Barcelona, Hosp Clin Barcelona, Dept Radiol, Barcelona, Spain
关键词
dual-energy computed tomography; virtual unenhanced; conventional unenhanced; liver lesion; image quality; artifacts; NONENHANCED IMAGES; CONTRAST MATERIAL; RENAL MASSES; CT DECT; REPAIR; TRUE;
D O I
10.1097/RLI.0b013e31826e7902
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purposes: We aimed to analyze the image quality, CT number, artifacts, radiation dose reduction, and coverage in abdominal virtual unenhanced (VU) and conventional unenhanced (CU) data sets obtained with a second-generation dual-energy computed tomography and to compare the sensitivity of VU and CU data sets for liver lesion detection. Materials and Methods: One hundred eleven patients underwent triphasic abdominal CT examination that included single-energy CU and dual-energy arterial and portal phases. Virtual unenhanced images were generated from arterial (AVU) and portal (PVU) phases. Two abdominal radiologists independently (a) analyzed the image quality using a 5-point scale, CT number, and noise of the abdominal organs and (b) identified and characterized liver lesions in CU, AVU, and PVU. The triphasic abdominal examination was considered the reference standard for liver lesion detection and characterization. Results: The quality of VU images was mostly excellent but not as good as CU images (P < 0.05). The mean (SD) image quality classified by readers 1 and 2 was 4.9 (0.2; range, 4.7-5.0) and 4.8 (0.5; range, 4.4-4.9) for CU, 4.7 (0.4; range, 4.3-4.9) and 4.6 (0.4; range, 4.2-4.8) for AVU, and 4.7 (0.6; range, 4.1-4.8) and 4.6 (0.4; range, 4.2-4.8) for PVU, respectively. The CT number of the liver, the spleen, the pancreas, the renal cortex and medulla, the aorta, and the retroperitoneal fat was higher in AVU and PVU than in CU images. A total of 270 liver lesions were found in 76 patients. Portal virtual unenhanced data set was more sensitive than AVU and CU were for hypodense lesions smaller than 1 cm. Reader 1 correctly detected 72/144 (50.0%), 61/144 (42.4%), and 55/144 (38.2%) hypodense lesions with PVU, AVU, and CU, respectively; and reader 2 correctly diagnosed 70/144 (48.7%), 62/144 (43.0%), and 53/144 (36.8%) lesions with PVU, AVU, and CU, respectively. Conventional unenhanced data set was more sensitive than AVU or PVU was for small calcified lesions. Reader 1 detected 24/40 (60.0%), 24/40 (60.0%), and 40/40 (100%) with PVU, AVU, and CU, respectively; and reader 2 detected 27/40 (67.5%), (25/40) 62.5%, and 40/40 (100%) with PVU, AVU, and CU, respectively. The dose reduction achieved by omitting the unenhanced acquisition was a mean (SD) of 21.1% (1.2%; P < 0.01). Conclusions: Second-generation abdominal VU data sets, despite a mostly excellent image quality, still cannot replace CU images in clinical practice because of limitations in material subtraction. Advances in Knowledge: 1. Second-generation abdominal VU data sets yield excellent image quality but are still slightly lower than that of CU. 2. More small hypodense liver lesions were detected in VU images than in CU images; however, a significant number of small calcified lesions were not identified in VU images. 3. Second-generation abdominal VU images are still not ready to replace CU images in clinical practice. Implications for Patient Care: 1. Using VU images in abdominal studies makes it possible to reduce the total radiation dose delivered to patients who need multiphasic acquisition by avoiding precontrast scan. 2. Erroneous material subtraction and incomplete abdominal coverage represent a limit in VU data set application in clinical routine.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
[41]   Dynamic imaging with dual-source gated Computed Tomography (CT): Implications of motion parameters on image quality for wrist imaging [J].
Neo, Puay Yong ;
Jais, Ita Suzana Mat ;
Panknin, Christoph ;
Lau, Chin Cheung ;
Chan, Lai Peng ;
An, Kai Nan ;
Tay, Shian Chao .
MEDICAL ENGINEERING & PHYSICS, 2013, 35 (12) :1837-1842
[42]   Optimization of wrist tendon detection in virtual monochromatic images using dual energy-computed tomography [J].
Nishiyama, Norimi ;
Masuda, Takanori ;
Nakagawa, Junnichi ;
Terami, Keisuke ;
Nakaura, Takeshi .
JAPANESE JOURNAL OF RADIOLOGY, 2023, 41 (12) :1397-1404
[43]   Comparison of virtual to true unenhanced abdominal computed tomography images acquired using rapid kV-switching dual energy imaging [J].
Popnoe, D. Olivia ;
Ng, Chaan S. ;
Zhou, Shouhao ;
Kaur, Harmeet ;
Kang, Hyunseon C. ;
Loyer, Evelyne M. ;
Kappadath, S. Cheenu ;
Jones, A. Kyle .
PLOS ONE, 2020, 15 (09)
[44]   Detection of moderate hepatic steatosis on contrast-enhanced dual-source dual-energy CT: Role and accuracy of virtual non-contrast CT [J].
Catania, Roberta ;
Jia, Leo ;
Haghshomar, Maryam ;
Miller, Frank H. ;
Borhani, Amir A. .
EUROPEAN JOURNAL OF RADIOLOGY, 2024, 172
[45]   Dual-Energy Spectral Computed Tomography With Adaptive Statistical Iterative Reconstruction for Improving Image Quality of Portal Venography [J].
Wang, Weibing ;
Huang, Jinbai ;
Wang, Ai ;
Li, Yun ;
Peng, Jie ;
Hu, Xinjie ;
Liu, Yingjun ;
Zhang, Haiyan ;
Li, Xiaohu .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) :954-958
[46]   Diagnosis of Pulmonary Artery Embolism: Comparison of Single-Source CT and 3rd Generation Dual-Source CT using a Dual-Energy Protocol Regarding Image Quality and Radiation Dose [J].
Petritsch, Bernhard ;
Kosmala, Aleksander ;
Gassenmaier, Tobias ;
Weng, Andreas Max ;
Veldhoen, Simon ;
Kunz, Andreas Steven ;
Bley, Thorsten Alexander .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2017, 189 (06) :527-536
[47]   Initial Results of a Single-Source Dual-Energy Computed Tomography Technique Using a Split-Filter Assessment of Image Quality, Radiation Dose, and Accuracy of Dual-Energy Applications in an In Vitro and In Vivo Study [J].
Euler, Andre ;
Parakh, Anushri ;
Falkowski, Anna L. ;
Manneck, Sebastian ;
Dashti, David ;
Krauss, Bernhard ;
Szucs-Farkas, Zsolt ;
Schindera, Sebastian T. .
INVESTIGATIVE RADIOLOGY, 2016, 51 (08) :491-498
[48]   Deep learning image reconstruction algorithm for pancreatic protocol dual-energy computed tomography: image quality and quantification of iodine concentration [J].
Noda, Yoshifumi ;
Kawai, Nobuyuki ;
Nagata, Shoma ;
Nakamura, Fumihiko ;
Mori, Takayuki ;
Miyoshi, Toshiharu ;
Suzuki, Ryosuke ;
Kitahara, Fumiya ;
Kato, Hiroki ;
Hyodo, Fuminori ;
Matsuo, Masayuki .
EUROPEAN RADIOLOGY, 2022, 32 (01) :384-394
[49]   Deep learning image reconstruction algorithm for carotid dual-energy computed tomography angiography: evaluation of image quality and diagnostic performance [J].
Chenyu Jiang ;
Dan Jin ;
Zhuoheng Liu ;
Yan Zhang ;
Ming Ni ;
Huishu Yuan .
Insights into Imaging, 13
[50]   Deep learning image reconstruction algorithm for carotid dual-energy computed tomography angiography: evaluation of image quality and diagnostic performance [J].
Jiang, Chenyu ;
Jin, Dan ;
Liu, Zhuoheng ;
Zhang, Yan ;
Ni, Ming ;
Yuan, Huishu .
INSIGHTS INTO IMAGING, 2022, 13 (01)