Virtual Unenhanced Images of the Abdomen With Second-Generation Dual-Source Dual-Energy Computed Tomography Image Quality and Liver Lesion Detection

被引:67
作者
De Cecco, Carlo Nicola [1 ]
Darnell, Anna [2 ]
Macias, Napoleon [2 ]
Ramon Ayuso, Juan [2 ]
Rodriguez, Sonia [2 ]
Rimola, Jordi [2 ]
Pages, Mario [2 ]
Garcia-Criado, Angeles [2 ]
Rengo, Marco [1 ]
Laghi, Andrea [1 ]
Ayuso, Carmen [2 ]
机构
[1] Univ Roma La Sapienza, Dept Radiol Sci Oncol & Pathol, I-01400 Latina, Italy
[2] Univ Barcelona, Hosp Clin Barcelona, Dept Radiol, Barcelona, Spain
关键词
dual-energy computed tomography; virtual unenhanced; conventional unenhanced; liver lesion; image quality; artifacts; NONENHANCED IMAGES; CONTRAST MATERIAL; RENAL MASSES; CT DECT; REPAIR; TRUE;
D O I
10.1097/RLI.0b013e31826e7902
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purposes: We aimed to analyze the image quality, CT number, artifacts, radiation dose reduction, and coverage in abdominal virtual unenhanced (VU) and conventional unenhanced (CU) data sets obtained with a second-generation dual-energy computed tomography and to compare the sensitivity of VU and CU data sets for liver lesion detection. Materials and Methods: One hundred eleven patients underwent triphasic abdominal CT examination that included single-energy CU and dual-energy arterial and portal phases. Virtual unenhanced images were generated from arterial (AVU) and portal (PVU) phases. Two abdominal radiologists independently (a) analyzed the image quality using a 5-point scale, CT number, and noise of the abdominal organs and (b) identified and characterized liver lesions in CU, AVU, and PVU. The triphasic abdominal examination was considered the reference standard for liver lesion detection and characterization. Results: The quality of VU images was mostly excellent but not as good as CU images (P < 0.05). The mean (SD) image quality classified by readers 1 and 2 was 4.9 (0.2; range, 4.7-5.0) and 4.8 (0.5; range, 4.4-4.9) for CU, 4.7 (0.4; range, 4.3-4.9) and 4.6 (0.4; range, 4.2-4.8) for AVU, and 4.7 (0.6; range, 4.1-4.8) and 4.6 (0.4; range, 4.2-4.8) for PVU, respectively. The CT number of the liver, the spleen, the pancreas, the renal cortex and medulla, the aorta, and the retroperitoneal fat was higher in AVU and PVU than in CU images. A total of 270 liver lesions were found in 76 patients. Portal virtual unenhanced data set was more sensitive than AVU and CU were for hypodense lesions smaller than 1 cm. Reader 1 correctly detected 72/144 (50.0%), 61/144 (42.4%), and 55/144 (38.2%) hypodense lesions with PVU, AVU, and CU, respectively; and reader 2 correctly diagnosed 70/144 (48.7%), 62/144 (43.0%), and 53/144 (36.8%) lesions with PVU, AVU, and CU, respectively. Conventional unenhanced data set was more sensitive than AVU or PVU was for small calcified lesions. Reader 1 detected 24/40 (60.0%), 24/40 (60.0%), and 40/40 (100%) with PVU, AVU, and CU, respectively; and reader 2 detected 27/40 (67.5%), (25/40) 62.5%, and 40/40 (100%) with PVU, AVU, and CU, respectively. The dose reduction achieved by omitting the unenhanced acquisition was a mean (SD) of 21.1% (1.2%; P < 0.01). Conclusions: Second-generation abdominal VU data sets, despite a mostly excellent image quality, still cannot replace CU images in clinical practice because of limitations in material subtraction. Advances in Knowledge: 1. Second-generation abdominal VU data sets yield excellent image quality but are still slightly lower than that of CU. 2. More small hypodense liver lesions were detected in VU images than in CU images; however, a significant number of small calcified lesions were not identified in VU images. 3. Second-generation abdominal VU images are still not ready to replace CU images in clinical practice. Implications for Patient Care: 1. Using VU images in abdominal studies makes it possible to reduce the total radiation dose delivered to patients who need multiphasic acquisition by avoiding precontrast scan. 2. Erroneous material subtraction and incomplete abdominal coverage represent a limit in VU data set application in clinical routine.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
[1]   Virtual unenhanced imaging of the liver with third-generation dual-source dual-energy CT and advanced modeled iterative reconstruction [J].
De Cecco, Carlo N. ;
Muscogiuri, Giuseppe ;
Schoepf, U. Joseph ;
Caruso, Damiano ;
Wichmann, Julian L. ;
Cannao, Paola M. ;
Canstein, Christian ;
Fuller, Stephen R. ;
Snider, Lauren ;
Varga-Szemes, Akos ;
Hardie, Andrew D. .
EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (07) :1257-1264
[2]   Interscanner and Intrascanner Comparison of Virtual Unenhanced Attenuation Values Derived From Twin Beam Dual-Energy and Dual-Source, Dual-Energy Computed Tomography [J].
Obmann, Markus M. ;
Kelsch, Vanessa ;
Cosentino, Aurelio ;
Hofmann, Verena ;
Boll, Daniel T. ;
Benz, Matthias R. .
INVESTIGATIVE RADIOLOGY, 2019, 54 (01) :1-6
[3]   Comprehensive Comparison of Virtual Monoenergetic and Linearly Blended Reconstruction Techniques in Third-Generation Dual-Source Dual-Energy Computed Tomography Angiography of the Thorax and Abdomen [J].
Albrecht, Moritz H. ;
Trommer, Jesko ;
Wichmann, Julian L. ;
Scholtz, Jan-Erik ;
Martin, Simon S. ;
Lehnert, Thomas ;
Vogl, Thomas J. ;
Bodelle, Boris .
INVESTIGATIVE RADIOLOGY, 2016, 51 (09) :582-590
[4]   Abdominal Attenuation Values on Virtual and True Unenhanced Images Obtained With Third-Generation Dual-Source Dual-Energy CT [J].
Durieux, Pierre ;
Gevenois, Pierre Alain ;
Van Muylem, Alain ;
Howarth, Nigel ;
Keyzer, Caroline .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (05) :1042-1058
[5]   Virtual non-contrast in second-generation, dual-energy computed tomography: Reliability of attenuation values [J].
Toepker, Michael ;
Moritz, Thomas ;
Krauss, Bernhard ;
Weber, Michael ;
Euller, Gordon ;
Mang, Thomas ;
Wolf, Florian ;
Herold, Christian J. ;
Ringl, Helmut .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (03) :E398-E405
[6]   Virtual unenhanced second generation dual-source CT of the liver: Is it time to discard the conventional unenhanced phase? [J].
Barrett, T. ;
Bowden, D. J. ;
Shaida, N. ;
Godfrey, E. M. ;
Taylor, A. ;
Lomas, D. J. ;
Shaw, A. S. .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (07) :1438-1445
[7]   Optimization of energy level for coronary angiography with dual-energy and dual-source computed tomography [J].
Okayama, Satoshi ;
Seno, Ayako ;
Soeda, Tsunenari ;
Takami, Yasuhiro ;
Kawakami, Rika ;
Somekawa, Satoshi ;
Ishigami, Ken-ichi ;
Takeda, Yukiji ;
Kawata, Hiroyuki ;
Horii, Manabu ;
Uemura, Shiro ;
Saito, Yoshihiko .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (04) :901-909
[8]   Second-Generation Dual-Energy Computed Tomography of the Abdomen: Radiation Dose Comparison With 64-and 128-Row Single-Energy Acquisition [J].
De Cecco, Carlo Nicola ;
Darnell, Anna ;
Macias, Napoleon ;
Ramon Ayuso, Juan ;
Rodriguez, Sonia ;
Rimola, Jordi ;
Pages, Mario ;
Garcia-Criado, Angeles ;
Rengo, Marco ;
Muscogiuri, Giuseppe ;
Laghi, Andrea ;
Ayuso, Carmen .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (04) :543-546
[9]   Advanced virtual monochromatic reconstruction of dual-energy unenhanced brain computed tomography in children: comparison of image quality against standard mono-energetic images and conventional polychromatic computed tomography [J].
Park, Juil ;
Choi, Young Hun ;
Cheon, Jung-Eun ;
Kim, Woo Sun ;
Kim, In-One ;
Pak, Seong Yong ;
Krauss, Bernhard .
PEDIATRIC RADIOLOGY, 2017, 47 (12) :1648-1658
[10]   Image Quality Performance of Virtual Single-Source CT Using Dual-Source Computed Tomography [J].
Alikhani, Babak ;
Werner, Martin ;
Jamali, Leila ;
Wacker, Frank ;
Werncke, Thomas .
ACADEMIC RADIOLOGY, 2019, 26 (08) :1095-1101