Virtual Unenhanced Images of the Abdomen With Second-Generation Dual-Source Dual-Energy Computed Tomography Image Quality and Liver Lesion Detection

被引:66
|
作者
De Cecco, Carlo Nicola [1 ]
Darnell, Anna [2 ]
Macias, Napoleon [2 ]
Ramon Ayuso, Juan [2 ]
Rodriguez, Sonia [2 ]
Rimola, Jordi [2 ]
Pages, Mario [2 ]
Garcia-Criado, Angeles [2 ]
Rengo, Marco [1 ]
Laghi, Andrea [1 ]
Ayuso, Carmen [2 ]
机构
[1] Univ Roma La Sapienza, Dept Radiol Sci Oncol & Pathol, I-01400 Latina, Italy
[2] Univ Barcelona, Hosp Clin Barcelona, Dept Radiol, Barcelona, Spain
关键词
dual-energy computed tomography; virtual unenhanced; conventional unenhanced; liver lesion; image quality; artifacts; NONENHANCED IMAGES; CONTRAST MATERIAL; RENAL MASSES; CT DECT; REPAIR; TRUE;
D O I
10.1097/RLI.0b013e31826e7902
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purposes: We aimed to analyze the image quality, CT number, artifacts, radiation dose reduction, and coverage in abdominal virtual unenhanced (VU) and conventional unenhanced (CU) data sets obtained with a second-generation dual-energy computed tomography and to compare the sensitivity of VU and CU data sets for liver lesion detection. Materials and Methods: One hundred eleven patients underwent triphasic abdominal CT examination that included single-energy CU and dual-energy arterial and portal phases. Virtual unenhanced images were generated from arterial (AVU) and portal (PVU) phases. Two abdominal radiologists independently (a) analyzed the image quality using a 5-point scale, CT number, and noise of the abdominal organs and (b) identified and characterized liver lesions in CU, AVU, and PVU. The triphasic abdominal examination was considered the reference standard for liver lesion detection and characterization. Results: The quality of VU images was mostly excellent but not as good as CU images (P < 0.05). The mean (SD) image quality classified by readers 1 and 2 was 4.9 (0.2; range, 4.7-5.0) and 4.8 (0.5; range, 4.4-4.9) for CU, 4.7 (0.4; range, 4.3-4.9) and 4.6 (0.4; range, 4.2-4.8) for AVU, and 4.7 (0.6; range, 4.1-4.8) and 4.6 (0.4; range, 4.2-4.8) for PVU, respectively. The CT number of the liver, the spleen, the pancreas, the renal cortex and medulla, the aorta, and the retroperitoneal fat was higher in AVU and PVU than in CU images. A total of 270 liver lesions were found in 76 patients. Portal virtual unenhanced data set was more sensitive than AVU and CU were for hypodense lesions smaller than 1 cm. Reader 1 correctly detected 72/144 (50.0%), 61/144 (42.4%), and 55/144 (38.2%) hypodense lesions with PVU, AVU, and CU, respectively; and reader 2 correctly diagnosed 70/144 (48.7%), 62/144 (43.0%), and 53/144 (36.8%) lesions with PVU, AVU, and CU, respectively. Conventional unenhanced data set was more sensitive than AVU or PVU was for small calcified lesions. Reader 1 detected 24/40 (60.0%), 24/40 (60.0%), and 40/40 (100%) with PVU, AVU, and CU, respectively; and reader 2 detected 27/40 (67.5%), (25/40) 62.5%, and 40/40 (100%) with PVU, AVU, and CU, respectively. The dose reduction achieved by omitting the unenhanced acquisition was a mean (SD) of 21.1% (1.2%; P < 0.01). Conclusions: Second-generation abdominal VU data sets, despite a mostly excellent image quality, still cannot replace CU images in clinical practice because of limitations in material subtraction. Advances in Knowledge: 1. Second-generation abdominal VU data sets yield excellent image quality but are still slightly lower than that of CU. 2. More small hypodense liver lesions were detected in VU images than in CU images; however, a significant number of small calcified lesions were not identified in VU images. 3. Second-generation abdominal VU images are still not ready to replace CU images in clinical practice. Implications for Patient Care: 1. Using VU images in abdominal studies makes it possible to reduce the total radiation dose delivered to patients who need multiphasic acquisition by avoiding precontrast scan. 2. Erroneous material subtraction and incomplete abdominal coverage represent a limit in VU data set application in clinical routine.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [1] Interscanner and Intrascanner Comparison of Virtual Unenhanced Attenuation Values Derived From Twin Beam Dual-Energy and Dual-Source, Dual-Energy Computed Tomography
    Obmann, Markus M.
    Kelsch, Vanessa
    Cosentino, Aurelio
    Hofmann, Verena
    Boll, Daniel T.
    Benz, Matthias R.
    INVESTIGATIVE RADIOLOGY, 2019, 54 (01) : 1 - 6
  • [2] Pre-operative Percutaneous Nephrolithotripsy Characterisation of Kidney Stones with Second-Generation Dual-Source Dual-Energy Computed Tomography
    Ali, D. K. Mella Mohd
    Mahmud, Mohd Hafizi
    Mohamad, Noor Shafini
    MALAYSIAN JOURNAL OF MEDICAL SCIENCES, 2020, 27 (05): : 43 - 52
  • [3] Abdominal Attenuation Values on Virtual and True Unenhanced Images Obtained With Third-Generation Dual-Source Dual-Energy CT
    Durieux, Pierre
    Gevenois, Pierre Alain
    Van Muylem, Alain
    Howarth, Nigel
    Keyzer, Caroline
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (05) : 1042 - 1058
  • [4] Virtual unenhanced second generation dual-source CT of the liver: Is it time to discard the conventional unenhanced phase?
    Barrett, T.
    Bowden, D. J.
    Shaida, N.
    Godfrey, E. M.
    Taylor, A.
    Lomas, D. J.
    Shaw, A. S.
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (07) : 1438 - 1445
  • [5] Virtual unenhanced imaging of the liver with third-generation dual-source dual-energy CT and advanced modeled iterative reconstruction
    De Cecco, Carlo N.
    Muscogiuri, Giuseppe
    Schoepf, U. Joseph
    Caruso, Damiano
    Wichmann, Julian L.
    Cannao, Paola M.
    Canstein, Christian
    Fuller, Stephen R.
    Snider, Lauren
    Varga-Szemes, Akos
    Hardie, Andrew D.
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (07) : 1257 - 1264
  • [6] Unsupervised deep learning based image outpainting for dual-source, dual-energy computed tomography
    Liu, Chi-Kuang
    Huang, Hsuan-Ming
    RADIATION PHYSICS AND CHEMISTRY, 2021, 188
  • [7] Comprehensive Comparison of Virtual Monoenergetic and Linearly Blended Reconstruction Techniques in Third-Generation Dual-Source Dual-Energy Computed Tomography Angiography of the Thorax and Abdomen
    Albrecht, Moritz H.
    Trommer, Jesko
    Wichmann, Julian L.
    Scholtz, Jan-Erik
    Martin, Simon S.
    Lehnert, Thomas
    Vogl, Thomas J.
    Bodelle, Boris
    INVESTIGATIVE RADIOLOGY, 2016, 51 (09) : 582 - 590
  • [8] Tube Current Modulation Between Single- and Dual-Energy CT With a Second-Generation Dual-Source Scanner: Radiation Dose and Image Quality
    Matsubara, Kosuke
    Takata, Tadanori
    Kobayashi, Masanao
    Kobayashi, Satoshi
    Koshida, Kichiro
    Gabata, Toshifumi
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 207 (02) : 354 - 361
  • [9] Optimization of energy level for coronary angiography with dual-energy and dual-source computed tomography
    Satoshi Okayama
    Ayako Seno
    Tsunenari Soeda
    Yasuhiro Takami
    Rika Kawakami
    Satoshi Somekawa
    Ken-ichi Ishigami
    Yukiji Takeda
    Hiroyuki Kawata
    Manabu Horii
    Shiro Uemura
    Yoshihiko Saito
    The International Journal of Cardiovascular Imaging, 2012, 28 : 901 - 909
  • [10] Optimization of energy level for coronary angiography with dual-energy and dual-source computed tomography
    Okayama, Satoshi
    Seno, Ayako
    Soeda, Tsunenari
    Takami, Yasuhiro
    Kawakami, Rika
    Somekawa, Satoshi
    Ishigami, Ken-ichi
    Takeda, Yukiji
    Kawata, Hiroyuki
    Horii, Manabu
    Uemura, Shiro
    Saito, Yoshihiko
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (04): : 901 - 909