Potentiometric flow injection determination of salbutamol

被引:11
作者
Abdel-Ghani, NT [1 ]
Rizk, MS [1 ]
El-Nashar, RM [1 ]
机构
[1] Cairo Univ, Fac Sci, Dept Chem, Cairo, Egypt
关键词
salbutamol; ion-selective electrodes; flow injection analysis; potentiometry;
D O I
10.1081/AL-120002360
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Potentiometric detection of salbutamol sulphate Sl(2)SO(4) using electrodes containing its ion-exchangers with phosphotungstic; phosphomolybdic acid or a mixture of both was applied in flow injection systems in the Nernastian range of the electrodes response. The selectivity of these electrodes towards different cations was studied in comparison to that obtained in batch conditions. The method was then used to determine the drug in its pharmaceutical preparations.
引用
收藏
页码:39 / 52
页数:14
相关论文
共 35 条
[1]   Salbutamol plastic membrane electrodes based on individual and mixed ion-exchangers of salbutamolium phosphotungstate and phosphomolybdate [J].
Abdel-Ghani, NT ;
Rizk, MS ;
El-Nashar, RM .
ANALYST, 2000, 125 (06) :1129-1133
[2]   Rapid resolution of drugs and related substances with an eCAP(TM) polyamine coated capillary [J].
Assi, KA ;
Altria, KD ;
Clark, BJ .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 15 (08) :1041-1049
[3]  
Biancotto G, 1997, J MASS SPECTROM, V32, P781, DOI 10.1002/(SICI)1096-9888(199707)32:7<781::AID-JMS532>3.0.CO
[4]  
2-5
[5]   VOLTAMMETRIC STUDY OF SALBUTAMOL, FENOTEROL AND METAPROTERENOL AT UNMODIFIED AND NAFION-MODIFIED CARBON-PASTE ELECTRODES [J].
BOYD, D ;
RODRIGUEZ, JRB ;
ORDIERES, AJM ;
BLANCO, PT ;
SMYTH, MR .
ANALYST, 1994, 119 (09) :1979-1984
[6]  
Chen X, 1998, YAOWU FENXI ZAZHI, V18, P98
[7]   COMPARISON OF DETECTOR CELL CONFIGURATIONS IN FLOW-INJECTION POTENTIOMETRY [J].
DAVEY, DE ;
MULCAHY, DE ;
OCONNELL, GR .
ELECTROANALYSIS, 1993, 5 (07) :581-588
[8]   Calibration of gas chromatography mass spectrometry of two-component mixtures using univariate regression and two- and three-way partial least squares [J].
Demir, C ;
Brereton, RG .
ANALYST, 1997, 122 (07) :631-638
[9]   Determination of salbutamol enantiomers by high-performance capillary electrophoresis and its application to dissolution assays [J].
Esquisabel, A ;
Hernandez, RM ;
Gascon, AR ;
Igartua, M ;
Calvo, B ;
Pedraz, JL .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 16 (02) :357-366
[10]   THE FLUORIDE ION-SELECTIVE ELECTRODE IN FLOW-INJECTION ANALYSIS .1. GENERAL METHODOLOGY [J].
FRENZEL, W ;
BRATTER, P .
ANALYTICA CHIMICA ACTA, 1986, 185 :127-136